# Fisher control valves: globe, rotary and severe service

> Fisher sliding-stem and rotary control valves, anti-cavitation and noise-reduction trims. What data to send for a quote and repair service.

Source: https://its-ve.com/en/products/final-control/control-valves/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- Control valves

[Final control](https://its-ve.com/en/products/final-control/)

Final control · Category

# Fisher control valves

Globe and rotary valves for standard and severe service, with anti-cavitation and low-noise trims.

[Quote control valves](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20control%20valve) See the designs

- Overview
- Globe
- Rotary
- Severe service
- Models
- Sizing
- Services
- FAQ

## What is a control valve?

A control valve is the final element of a control loop: it changes the flow of a fluid to hold flow, pressure, level or temperature at the value set by the controller.

It consists of the body, which contains the pressure; the trim (plug, seat, cage and stem), which defines the flow characteristic; and the actuator, which moves the plug according to the positioner signal. It is selected by fluid, pressure, temperature, flow and risk of cavitation or noise.

- ### Meet changing process demands with trim variations. Globe valves accept interchangeable cages and plugs to modify the flow characteristic. Globe valves
- ### High capacity and precise control at a lower total cost. Rotary valves give high-capacity control across a broad range of applications. Rotary valves
- ### Longer operating life in the most difficult installations. Severe-service trims protect against cavitation, flashing, erosion and noise. Critical and severe service
- ### Bring the installed valve back to specification. Genuine trim, cages, seats and packing, with our own shop in Puerto Ordaz. [Fisher OEM parts](https://its-ve.com/en/products/final-control/fisher-oem-parts/)

## Globe control valves

Meet changing process demands by changing the trim, not the valve.

Sliding-stem globe valves cover small to large sizes and general to severe service. Their interchangeable cages and plugs modify the flow characteristic, linear, equal-percentage or quick-opening, to match the capacity the process demands.

### What’s your challenge?

Processes change and the installed valve no longer fits the service.

### What’s your opportunity?

One globe body accepts a broad choice of trim sizes and styles: the valve adapts and the investment is protected.

### Globe valves

**Globe valves.** The standard of process control: sliding stem, the widest choice of trim and pressure ratings for the most demanding services.

- easy-e ED
- easy-e ES
- easy-e ET
- easy-e EZ
- easy-e EW
- HP
- EH
- GX
- D4

### Angle valves

**Angle valves.** Sliding-stem control with a 90° turn: for erosive, flashing and high-pressure service, and for piping where the valve doubles as an elbow.

- FB
- D / DA

### Three-way valves

**Three-way valves.** One body that blends two streams or splits one: thermal and blending control with fewer valves in the loop.

- YD / YS
- Baumann 24003

## Rotary control valves

High capacity and precise control at a lower total cost.

For a given body size, a rotary valve offers far more capacity than a globe valve, which makes it attractive where the pressure drop is small. The family includes full-bore ball, segmented ball, high-performance butterfly and eccentric plug styles, with such familiar names as Vee-Ball and Control-Disk.

### What’s your challenge?

Capacity or line size constrains the valve selection.

### What’s your opportunity?

More flow per size, wide control ranges, compact bodies and better shaft sealing.

### Full-bore ball valves

**Full-bore ball valves.** High capacity at low pressure drop: full-bore rotary control for gas transmission and large-diameter lines.

- V260
- V270
- V280

### Segmented ball valves

**Segmented ball valves.** V-notch ball: wide rangeability, high capacity and a self-cleaning shearing action for erosive, viscous and fibrous fluids.

- Vee-Ball V150
- Vee-Ball V200
- Vee-Ball V300
- Vee-Ball V150S

### High-performance butterfly valves

**High-performance butterfly valves.** Effective, economical throttling in large lines and high temperature, with the Control-Disk extending the control range toward a segmented ball.

- Control-Disk
- 8580
- 8590
- 8560
- A11

### Eccentric plug valves

**Eccentric plug valves.** Globe-valve ruggedness with rotary efficiency: the plug cams into the seat, with low friction and long life in erosive fluids.

- V500
- CV500

## Critical and severe service

Longer operating life in the most difficult installations.

When the pressure drop destroys a standard trim, the problem is not the valve: it is the phenomenon. Cavitation, flashing, aerodynamic noise, erosion and high temperature each have their trim, and the selection is decided at sizing, not at repair.

### What’s your challenge?

There is no single method for choosing the trim when there is cavitation, noise or flashing.

### What’s your opportunity?

With the phenomenon correctly diagnosed, the right trim removes the cause of the damage instead of repairing its effects.

[Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/)
Plug and cage with cavitation damage: what a standard trim looks like after a service that called for staging.

### Noise control trims

They attenuate the aerodynamic and hydrodynamic noise generated by high pressure drops in gas, steam and liquids.

- Whisper NXG
- Whisper NXV

### Cavitation control trims

They stage the pressure drop so the liquid never reaches its vapor pressure, in clean and dirty service.

- Cavitrol III
- Cavitrol Hex
- Micro-Flat
- NotchFlo DST

### Steam conditioning

They reduce pressure and desuperheat steam in one unit to protect downstream equipment.

- TBX

Fisher models

## Control valves by model

Each model with its official technical bulletin, which you can read right here, and a quote one click away.

Find a model
- Increased-outlet angle control valve ### Fisher 461 Sweep-Flo Self-cleaning angle valve with a venturi-type throat, used in chemical and hydrocarbon service with residual oils or coking fluids. The increased outlet lowers fluid velocity and helps limit flashing and cavitation. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100036x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20461%20Sweep-Flo)
- Bronze globe control valve ### Fisher Baumann 24000 Bronze valve for general utility pressure, flow and temperature control. It combines low hysteresis, tight shutoff, rugged construction and easy maintenance, reducing process variability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103327x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000)
- Carbon steel globe control valve ### Fisher Baumann 24000C Globe valve with low hysteresis and deadband, good control, tight shutoff, high-performance packing and easy maintenance. It helps lower maintenance costs and process variability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103328x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000C)
- Carbon steel flanged globe control valve ### Fisher Baumann 24000CVF Compact carbon steel flanged globe valve built for tight shutoff and space-limited installations. Its light weight design reduces installed piping costs. [View bulletin](https://www.emerson.com/content/dam/emerson/en/final-control/flow-controls/documents/d103333x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000CVF)
- Wafer body globe control valve ### Fisher Baumann 24000F Compact wafer valve that mates with ASME and EN line flanges and controls liquids, gases and vapors. It gives flanged globe connection integrity at lower weight, in S31603 stainless steel or special alloys. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103330x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000F)
- Stainless steel globe control valve ### Fisher Baumann 24000S Versatile pneumatic valve for pressure, temperature, level and flow control. Its CF8M stainless steel body withstands mildly corrosive fluids at a cost near that of carbon steel. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103331x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000S)
- Bar stock control valve ### Fisher Baumann 24000SB Valve for low flow, high pressure and industrial control, with a Cv as low as 0.00013 for injection duty. Threaded, butt weld or flanged ends are offered, plus special high nickel alloys. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103334x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000SB)
- Stainless steel flanged globe control valve ### Fisher Baumann 24000SVF Compact stainless steel flanged globe valve built for tight shutoff and space-limited installations. Its light weight design reduces installed piping costs. [View bulletin](https://www.emerson.com/content/dam/emerson/en/final-control/flow-controls/documents/d103333x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024000SVF)
- Three-way control valve ### Fisher Baumann 24003 Three-way valve for flow and temperature control in mixing or diverting service. It uses a cast bronze or CF8M stainless body with S31600 stainless trim for extended service life. [View bulletin](https://www.emerson.com/content/dam/emerson/en/final-control/flow-controls/documents/d103329x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2024003)
- High-pressure, low-flow control valve ### Fisher Baumann 51000 Valve for demanding low-flow, high-pressure control, common in laboratories and pilot plants. Compact, in NPS 1/4 and 1/2 sizes, in cast stainless steel or N10276 nickel alloy. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103339x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2051000)
- Anti-cavitation control valve ### Fisher CAV4 Valve for clean cavitating service with pressure drops above 207 bar (3000 psi). Its Cavitrol IV trim has stages of growing flow area that take most of the drop before cavities can form. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101497x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CAV4)
- High-pressure globe control valve ### Fisher D Single-port high-pressure valve widely used in oil and gas production, suited to throttling or on/off control of gritty or sticky liquids and gases. Its massive guiding keeps the plug aligned in the seat. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100039x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D)
- High-pressure globe control valve ### Fisher D y DA Single-port, high-pressure valves widely used in oil and gas production to throttle or shut off gritty, sticky liquids and gases. The DA suits angle piping and drains itself. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100039x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D%20y%20DA)
- Angle control valve ### Fisher D2 Angle Angle valve with 1 NPT and 2 NPT end connections, used as a dump valve on gas separators and scrubbers and in other high-pressure natural gas production and compression service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104137x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D2%20Angle)
- Globe or angle control valve ### Fisher D2T High-pressure valve used as a dump valve on gas separators and scrubbers, also suited to gas production and compression. A pipe plug lets the body be set up as a globe or an angle valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104137x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D2T)
- Compact globe control valve ### Fisher D3 FloPro Compact, rugged valve from the D family, intended for on/off or throttling control. It can be fitted with pneumatic or electric actuation depending on what the application requires. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103269x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D3%20FloPro)
- Compact globe control valve ### Fisher D4 Compact, rugged globe valve for high-pressure throttling with pneumatic or electric actuation, used in oil and gas production. A removable groove pin allows quick plug replacement. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103039x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20D4)
- High-pressure globe control valve ### Fisher DA Single-port high-pressure valve common in oil and gas production, suited to throttling or on/off control of gritty or sticky liquids and gases. It can be piped in angle form and drains itself. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100039x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DA)
- Balanced-plug globe control valve ### Fisher easy-e EA Globe or angle valve for general applications with high process temperatures, featuring a balanced plug and cage-guided trim. It offers Class V or VI shutoff and optional ENVIRO-SEAL packing. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100022x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EA)
- Angle control valve ### Fisher easy-e EAD Angle version of the ED, single-port with a balanced plug, cage guiding and metal-to-metal seating. Suited to general service across a wide range of pressure drops and temperatures. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100017x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EAD)
- Globe control valve ### Fisher easy-e EAS Globe or angle body valve for oil and gas production, including sulfide and chloride stress-cracking environments. It accepts ENVIRO-SEAL packing for a better stem seal and offers Class V or VI shutoff. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EAS)
- High-temperature globe control valve ### Fisher easy-e EAT Valve for general applications with high process temperatures, with a balanced plug and cage-guided trim. In globe or angle body, it can provide up to Class V or VI shutoff. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100022x012-bulletin-et-eat-and-etr-sliding-stem-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EAT)
- Globe control valve ### Fisher easy-e ED Single-port control valve with a balanced plug and cage guiding, in globe or angle bodies. Suited to general service across a wide range of pressure drops and temperatures, with metal-to-metal seating. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100017x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20ED)
- Globe control valve ### Fisher easy-e EW EW series for oil and gas production, power plants with oversized piping and noise abatement at high-pressure gas reducing stations. It can be fitted with live-loaded ENVIRO-SEAL packing systems. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100023x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EW)
- Globe control valve ### Fisher easy-e EWD-NS EW series valve for oil and gas production, power plants with oversized piping and noise abatement at high-pressure gas reducing stations. It can be fitted with ENVIRO-SEAL packing systems. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100023x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EWD-NS)
- Globe control valve ### Fisher easy-e EWND-1 EW series valve for oil and gas production, power plants with oversized piping and noise abatement at high-pressure gas reducing stations. It can be fitted with ENVIRO-SEAL packing systems. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100023x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EWND-1)
- Globe control valve ### Fisher easy-e EZ Control valve for throttling or on/off duty in chemical and hydrocarbon processing, suited to viscous, non-lubricating or hard-to-handle fluids. Post guiding keeps the plug stable and lowers the chance of sticking. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100025x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20EZ)
- High-pressure globe control valve ### Fisher EH Valve designed for high-pressure applications, with flow-stream contouring for higher capacity and trim built for reliability in severe service. Standard drilled-hole cages add strength against destructive vibration. [View bulletin](https://www.emerson.com/is/content/emerson/emerson/en/final-control/flow-controls/documents/d100042x012-product-bulletin-eh-eha-fisher-eh-and-eha-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EH)
- High-pressure globe control valve ### Fisher EHT EH series valve designed for high pressure, with flow-stream contouring for higher capacity and trim built for reliability in severe service. Drilled-hole cages add strength against destructive vibration. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100394x012-instruction-manual-ehd-ehs-e-eht-nps-1-2-x-1-a-8-6-and-valves-1-2x1-through-8x6-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EHT)
- High-pressure globe control valve ### Fisher EHT-1 EH series valve for high pressure, with a contoured flow path for higher capacity and trim built for reliability in severe service. Its drilled-hole cages resist destructive vibration. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100394x012-instruction-manual-ehd-ehs-e-eht-nps-1-2-x-1-a-8-6-and-valves-1-2x1-through-8x6-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EHT-1)
- Severe-service control valve for urea ### Fisher EHU Valve built for severe service in urea and ammonium carbamate plants, in specialty alloys with a forged body. It includes ENVIRO-SEAL low-emissions packing for corrosion resistance and protection against packing leaks. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/fctl/solutions/documents/urea-application/flow-control-valve-blt-fisher-ehu-control-valves-for-urea-plants-d104797x012-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EHU)
- Low-noise angle control valve ### Fisher FB Angle valve for compressible fluids needing maximum noise attenuation and high capacity, such as main steam reducing, compressor bypass and sour gas service in petrochemical and gas plants. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100195x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FB)
- Control valve and actuator system ### Fisher GX Integrated valve and actuator system covering a wide range of flow and line sizes. A three-way version suits accurate temperature control, and engineered internal passages give a stable flow pattern. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/fisher-gx-control-valve-actuator-system-d103171x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20GX)
- High-pressure globe control valve ### Fisher HP Single-port globe or angle valve with metal seats and cage-guided plug, built for high-pressure service in power generation, hydrocarbon production, chemical processing and refining. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101635x012-bulletin-hp-series-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20HP)
- Anti-cavitation globe control valve ### Fisher NotchFlo DST Valve for dirty, cavitating services. Its trim splits the pressure drop into restriction and expansion stages and lets particles up to 12.7 mm pass through without plugging. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/D103036X012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20NotchFlo%20DST)
- Three-way cage-guided control valve ### Fisher YD YS Three-way valves for throttling or on/off service in balanced or unbalanced builds. The YD handles converging and diverging service and the YS converging service. They share easy-e bonnets, gaskets and packing. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100031x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20YD%20YS)
- High-performance butterfly valve ### Fisher 8532 Butterfly valve for extreme pressure and temperature, with tight shutoff and a pressure-assisted seal. Offered in fire-tested and cryogenic constructions, in wafer, lugged or double-flanged bodies. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101552x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%208532)
- High-performance butterfly valve ### Fisher 8540 Butterfly valve with an eccentrically mounted disk and soft seal ring that seals in both flow directions with pressure assistance. A square shaft accepts several actuators, for tight-shutoff duty. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%208540)
- High-performance butterfly valve ### Fisher 8560 Butterfly valve for throttling with extremely low leakage. The eccentrically mounted disk gives an approximately linear characteristic and serves throttling or on/off control through 90 degrees of rotation. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102028x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%208560)
- High-performance butterfly valve ### Fisher 8580 Butterfly valve with an eccentrically mounted disk and a soft or metal seal, giving improved shutoff and good throttling or on/off performance. Assembly action can be reversed without extra parts. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103299x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%208580)
- High-performance butterfly valve ### Fisher 8590 Lugged butterfly valve that holds tight shutoff across a wide range of pressure and temperature conditions. A splined or square shaft accepts a variety of actuators, handwheels and handlevers. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104017x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%208590)
- High-performance butterfly valve ### Fisher A11 High-performance butterfly valve for throttling and on/off service, in wafer or single-flange design. It keeps tight shutoff across a wide pressure and temperature range, including cryogenic duty. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104165x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20A11)
- Double-flange high-performance butterfly valve ### Fisher A31D Double-flange high-performance butterfly valve with splined or keyed shaft, for throttling or on/off service in NPS 3 to 12, CL150 and CL300. Its pressure-assisted seal gives tight shutoff. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d500213x0es.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20A31D)
- Rotary disk valve ### Fisher Control-Disk Rotary valve with an equal-percentage characteristic and a throttling range comparable to a segmented ball valve. It lets you hold closer to setpoint and helps reduce process variability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103297x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Control-Disk)
- Segmented ball rotary valve ### Fisher CV500 Valve combining the rangeability of a cammed, segmented V-notch ball with heavy-duty bearings, seals and body. It balances erosion resistance with pressure control for gases and liquids. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101606x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CV500)
- Segmented ball rotary valve ### Fisher CV500 CAVHEX Valve combining the rangeability of a cammed, segmented V-notch ball with heavy-duty bearings, seals and body. It balances erosion resistance with pressure control for gases and liquids. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CV500%20CAVHEX)
- Full-bore ball valve for isolation ### Fisher Digital Isolation DSV1000 Three-piece, trunnion-mounted, full-bore ball valve designed for isolation service in safety instrumented systems. It adds little or no flow restriction and is supplied as an engineered, tested assembly. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Digital%20Isolation%20DSV1000)
- Segmented ball valve for continuous catalyst regeneration ### Fisher SS-138B Segmented ball valve designed for continuous catalyst regeneration applications, with easy installation. It serves units that run this process. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103779x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20SS-138B)
- Eccentric plug rotary valve ### Fisher V500 Rotary valve combining globe-valve ruggedness with rotary efficiency, built for erosive, coking and other hard-to-handle fluids. It allows forward or reverse flow with tight shutoff in either direction. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100054x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20V500)
- Segmented ball valve for nuclear service ### Fisher Vee-Ball SS-84PSV4 Pressurizer spray valve for third generation PWR nuclear generating stations. NPS 4x3 body with NPS 4 buttweld ends and 3 inch Vee-Ball internal trim working against a spring-loaded sleeve seal. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103416x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20SS-84PSV4)
- Flanged segmented ball valve ### Fisher Vee-Ball V150 Rotary segmented ball valve with a flanged body, precision-machined parts and pressure-balanced seals. The flanged design removes exposed line bolting, shortening alignment and installation time. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101363x012-bulletin-vee-ball-v150-v200-and-v300-rotary-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V150)
- Expanded outlet segmented ball valve ### Fisher Vee-Ball V150E Flanged segmented ball valve whose outlet flange is one line size larger than the inlet. The growing flow area streamlines flow where larger downstream piping is specified. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103429x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V150E)
- Slurry segmented ball valve ### Fisher Vee-Ball V150S Rugged segmented ball valve with highly wear-resistant trim and an unrestricted straight-through flow path. Ideal for slurry, it lowers erosive damage to the adjoining pipework. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103154x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V150S)
- Segmented ball valve ### Fisher Vee-Ball V200 Rotary segmented ball valve for a broad range of applications, with precision-machined parts and pressure-balanced seals. Available with a flangeless or flanged body for flexible installation. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101363x012-bulletin-vee-ball-v150-v200-and-v300-rotary-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V200)
- Flangeless segmented ball valve ### Fisher Vee-Ball V200U Flangeless rotary valve with a segmented V-notch ball and a compact face-to-face dimension. Its straight-through flow handles gas, steam, liquids and fibrous slurries, with a durable HD metal seal. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104550x012-bulletin-vee-ball-v200u-rotary-control-valve-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V200U)
- Flanged segmented ball valve ### Fisher Vee-Ball V300 Rotary segmented ball valve with a flanged body and pressure-balanced seals for many applications. With no exposed line flange bolting, it cuts alignment and installation time and supports piping integrity. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101363x012-bulletin-vee-ball-v150-v200-and-v300-rotary-control-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Vee-Ball%20V300)
- Steam-atomized desuperheater ### Fisher ATST Desuperheater using steam-atomized water injection, whose nozzles form extremely fine droplets that vaporize quickly across a wide range of steam flows. Aimed at applications demanding top atomization and rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/fisher-atst-desuperheater-bulletin-d104731x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20ATST)
- Steam conditioning valve ### Fisher CVX Steam conditioning valve for cycling power plants and process applications that need precise control. It combines pressure and temperature control in a single valve for moderate to severe duty. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101423x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CVX)
- Variable geometry steam desuperheater ### Fisher DFA Desuperheater combining a water control element with variable geometry mechanical atomization, for moderate to high flow variation. It installs through a side flanged connection on NPS 8 or larger pipelines. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dfa-variable-geometry-desuperheater.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DFA)
- Mechanically atomized steam desuperheater ### Fisher DMA Simple mechanically atomized desuperheater with one or several fixed-geometry nozzles, for nearly constant loads. It installs through a flanged side connection on DN 150 or larger pipelines, with optional AF nozzles. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DMA)
- Steam-atomized steam desuperheater ### Fisher DSA Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA)
- Steam-atomized steam desuperheater ### Fisher DSA-A Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-A)
- Steam-atomized steam desuperheater ### Fisher DSA-B Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-B)
- Steam-atomized steam desuperheater ### Fisher DSA-C Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-C)
- Steam-atomized steam desuperheater ### Fisher DSA-D Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-D)
- Steam-atomized steam desuperheater ### Fisher DSA-E Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-E)
- Steam-atomized steam desuperheater ### Fisher DSA-F Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-F)
- Steam-atomized steam desuperheater ### Fisher DSA-G Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-G)
- Steam-atomized steam desuperheater ### Fisher DSA-H Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-H)
- Steam-atomized steam desuperheater ### Fisher DSA-J Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-J)
- Steam-atomized steam desuperheater ### Fisher DSA-K Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-K)
- Steam-atomized steam desuperheater ### Fisher DSA-L Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-L)
- Steam-atomized steam desuperheater ### Fisher DSA-M Desuperheater that uses high-pressure steam to atomize spraywater in low velocity steam lines. It installs through a flanged connection on DN 200 or larger pipelines, for applications needing high rangeability. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DSA-M)
- Venturi steam desuperheater ### Fisher DVI Desuperheater with no moving parts that injects spraywater at the venturi outlet for good mixing and atomization. It installs between flanges in DN 25 to DN 600 lines, for moderate load changes and low velocity steam. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/en-fisher-dma-dsa-dvi-bulletin-d101443x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DVI)
- Steam conditioning valve ### Fisher SVX Flow-down steam conditioning valve for turbine bypass systems. It combines pressure and temperature control in a single valve, for cycling power plants and critical process environments. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/documents/product-bulletin-fisher-svx-steam-conditioning-valve-en-12133286.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20SVX)
- Steam conditioning valve ### Fisher TBX Valve that reduces steam pressure and temperature to enable daily cycling of power plants. It protects reheater tubes, condensers and piping from excursions during steam turbine trips. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103052x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20TBX)
- Steam desuperheater ### Fisher TBX-T Desuperheater for steam lines from DN 200 to DN 1200 that holds temperature within 6°C (10°F) of saturation. Its CFD-designed spraywater manifold with AF nozzles promotes mixing and quick vaporization. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103795x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20TBX-T)
- Probe-type steam desuperheater ### Fisher Yarway 4300 TempLow Probe-type desuperheater that adds cooling water to the steam flow in response to a pneumatic or electric control signal. It can be installed in straight, vertical or horizontal pipe. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104714x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Yarway%204300%20TempLow)
- Heavy duty steam desuperheater ### Fisher Yarway AT-18/28 Forged A.T.-Temp desuperheater for medium and high pressure steam, adaptable to various boiler codes. It can also serve as a liquid-into-gas injector, often in high grade alloys such as stainless steel. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104714x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Yarway%20AT-18%2F28)
- Low capacity steam desuperheater ### Fisher Yarway AT-25 VenTemp Forged desuperheater for low capacity superheated steam systems with a fairly constant load. It offers a simple, cost-conscious yet effective way to control steam temperature. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104422x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Yarway%20AT-25%20VenTemp)
- Standard duty steam desuperheater ### Fisher Yarway AT-38/48 A.T.-Temp desuperheater developed for medium and low pressure steam applications. Its fabricated construction makes it easy to adapt to various boiler codes and material specifications. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104714x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Yarway%20AT-38%2F48)
- Pipe-style inline diffuser ### Fisher 6011 Pipe-style inline diffuser that shares the pressure drop with the control valve, letting it run at a lower pressure drop ratio and make less noise. It need not be installed next to the valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100194x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%206011)
- Vent diffuser ### Fisher 6012 Diffuser for atmospheric vents that places back pressure on the vent valve and shares the pressure drop, reducing noise and vibration. The 6013 adds an outer shell for power plant sky vent use. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%206012)
- Modal noise attenuator ### Fisher 6060 WhisperTube Passive reactive silencer installed downstream of the valve or other noisy equipment. Its internal acoustic cavities reduce noise across a broad frequency range with negligible pressure drop and no loss of flow capacity. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/bu-content/general/documents/FCV-BLT-Product-Bulletin_-Fisher-6060-WhisperTube-Modal-Attenuator-D104355X012-EN.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%206060%20WhisperTube)
- PTFE-lined control valve ### Fisher Baumann 26000 Corrosion-resistant valve with a flangeless wafer body and multi-spring diaphragm actuator. A tantalum or nickel alloy plug and PTFE seat give a wide control range, making it suited to pH control. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103337x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2026000)
- Packless diaphragm control valve ### Fisher Baumann 81000 Mikroseal valve for throttling liquids or gases with wide flow variations. Its packless design avoids stem packing leaks, and a nearly frictionless mechanism gives very precise positioning. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103340x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Baumann%2081000)
- Anti-cavitation trim ### Fisher CAV III Micro-Flat Combines the cavitation control of Cavitrol III trim with the very low flow capability of Micro-Flat, for clean cavitating liquids with high pressure drops and small flow rates. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102702x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CAV%20III%20Micro-Flat)
- Anti-cavitation trim for rotary valves ### Fisher Cavitrol Hex Severe-service trim for rotary valves that reduces the cavitation and noise behind pipeline vibration while keeping the efficiency of the rotary design. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Cavitrol%20Hex)
- Anti-cavitation trim ### Fisher Cavitrol III Cage trim with many specially shaped holes that stage the pressure drop and reduce turbulence, controlling or eliminating cavitation in clean liquids with high pressure drops. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100196x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Cavitrol%20III)
- Anti-cavitation trim for dirty service ### Fisher DST Trim for dirty, cavitating liquids: a series of restrictions and expansions with growing flow area stages the pressure drop while letting particles pass without plugging. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102310x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DST)
- Trim for outgassing service ### Fisher DST-G Trim for clean or dirty liquids with dissolved gases released as pressure falls. It stages the pressure drop to prevent the cavitation and erosion that outgassing causes. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103396x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DST-G)
- Cryogenic globe control valve ### Fisher easy-e Cryogenic Single-port globe valve in stainless steel with fabricated extension bonnets, for throttling or on/off control of liquids and gases at cryogenic temperatures down to -198°C (-325°F), including certain LNG services. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102189x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20Cryogenic)
- Cryogenic globe control valve ### Fisher easy-e ET-C Single-port globe valve in stainless steel with fabricated extension bonnets, for throttling or on/off control of liquids and gases at cryogenic temperatures down to -198°C (-325°F), including certain LNG services. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102189x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20easy-e%20ET-C)
- Live-loaded packing system ### Fisher ENVIRO-SEAL Live-loaded packing systems that improve stem sealing and limit emissions of process fluid. They can be retrofitted to existing valves or ordered with new ones, in ENVIRO-SEAL, IS and HS versions. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101638x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20ENVIRO-SEAL)
- High-viscosity polymer control valve ### Fisher HVP Valve widely used in the polymer industry, with integral body passages that carry a heat transfer fluid to keep the valve and process fluid hot. Internal passages are finished to 0.1 to 0.4 micrometers RMS. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101490x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20HVP)
- Inline diffuser ### Fisher Inline Diffusers Diffusers that split the system pressure drop between valve and diffuser, so the valve runs at a lower pressure drop ratio and makes less noise. Options include the 6010, the 6011 and the Whisper Disk. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100194x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Inline%20Diffusers)
- Anti-cavitation trim ### Fisher Micro-Flat Trim for clean, cavitating liquids at low flow rates. Rather than suppressing cavitation entirely, it confines it away from critical surfaces to limit damage to the control valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102702x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Micro-Flat)
- Multiport flow selector valve ### Fisher Multiport Valve and actuator assembly that diverts fluid from a flow line to a test outlet or sampler, and can manifold up to eight lines. An electronic actuator controls and monitors the selector, suited to well testing. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104330x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Multiport)
- Lined globe control valve ### Fisher RSS Valve for severely corrosive and toxic media, and also suited to pure media. A perfluoroalkoxy resin lining shields the metal parts and offers an economical alternative to alloy bodies. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101291x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20RSS)
- Low-noise trim for globe valves ### Fisher Whisper NXG Optimized Whisper trim that cuts noise by up to 30 dBA and gives 20% more flow capacity than previously possible. It allows smaller globe valves where capacity used to be the limit. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20NXG)
- Low-noise trim for Vee-Ball valves ### Fisher Whisper NXV Whisper trim for Vee-Ball V150, V200 and V300 valves, pairing rotary valve efficiency with acoustic attenuation in gas and vapor service. It can reach up to 20 dBA depending on service conditions. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104761x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20NXV)
- Aerodynamic low-noise cage ### Fisher Whisper Trim I Cage with multiple orifices of special shape, size and spacing that lowers noise from vapor, gas or steam flow. It keeps high flow capacity and the control and durability of standard easy-e trims. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100190x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20Trim%20I)
- Aerodynamic low-noise cage ### Fisher Whisper Trim III Cage that attenuates aerodynamic noise in vapor, gas or steam service with high pressure drops. With a properly sized valve body it can cut noise by up to 30 dBA compared with standard trim. [View brochure](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d352720x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20Trim%20III)
- Aerodynamic noise attenuation trim ### Fisher WhisperFlo Trim for very demanding vapor or gas service with high pressure drops where noise must be attenuated. With a suitable valve body it reduces noise by up to 40 dBA, and up to 50 dBA in special applications. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102362x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20WhisperFlo)
- Cryogenic injector ### Fisher Yarway AT-37/47 Injector developed to introduce process fluids into process gases under cryogenic conditions. It is built in fabricated construction and belongs to the Fisher Yarway line of equipment. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Yarway%20AT-37%2F47)

Manufacturer photos and technical bulletins. Fisher and FIELDVUE are marks of Emerson.

## How to size a control valve

Proper control valve selection is critical for your process loop.

Sizing means choosing the body, trim and size that control the process across its whole operating range, not just the size that passes the design flow. An oversized valve works near the seat, where control is worst and wear highest; a well-sized one works in its stable band.

The guide walks through service data, the flow coefficient Cv, choked flow, cavitation and flashing, the flow characteristic and the most common mistakes, with the Fisher Control Valve Handbook as the reference.

[Read the guide](https://its-ve.com/en/technical-library/how-to-size-a-control-valve/)

To quote

## What data to send to quote a control valve

With this data we size the valve or identify the existing one. For a replacement, the nameplate solves almost everything.

[Send my process data](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20control%20valve)
- Fluid and phase (liquid, gas, steam or two-phase)
- Minimum, normal and maximum flow
- Inlet and outlet pressure
- Operating temperature
- Density or molecular weight, and viscosity
- Line size and pressure class
- Required materials and end connection
- Control signal, instrument air and fail action (open or close)
- For a replacement: nameplate photo, serial number and tag

Service

## Services for this equipment

What we do on this equipment in the shop and in the field.

- ### Control valve repair Repair to the manufacturer’s specification, with bench tests and report.
- ### Trim restoration Engineering assessment of plug, seat and cage before rebuilding.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.

Projects

## Documented work

Chemical

### OXINOVA Plant

Client: Oxinova

Recovery of the installed Control Valve platform

Further reading

## Related articles and courses

- Article · Service [Cavitation in Control Valves: Causes, Damage and Solutions](https://its-ve.com/en/blog/control-valve-cavitation-causes-and-solutions/)
- Article · Training [Control Valve Handbook, 6th Edition: Spare Parts and Sustainability](https://its-ve.com/en/blog/control-valve-handbook-6th-edition-spare-parts/)
- Article · Training [Control Valve Selection, Sizing and Application: The Course That Prevents Costly Errors](https://its-ve.com/en/blog/control-valve-selection-sizing-course/)
- Course [1300 · Control Valve Engineering I](https://its-ve.com/en/services/training/1300-control-valve-engineering-i/)

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What is a control valve?
It is the final element of a control loop: it throttles the fluid to hold flow, pressure, level or temperature at the set value. It consists of a body, trim (plug, seat, cage and stem) and an actuator with a positioner.

Globe or rotary: when does each make sense?
Sliding-stem (globe) valves give precise control over a wide range and accept severe-service trims. Rotary valves (segmented ball, butterfly, eccentric disc) offer more capacity per size and lower cost in large diameters, with good controllability in clean services. Pressure drop, cavitation or noise risk, the fluid and the required rangeability decide.

What is the trim and why does it define performance?
The trim is the set of internal parts in contact with the fluid: plug, seat, cage and stem. Its geometry defines the flow characteristic, capacity and shutoff class; its material, the resistance to erosion, cavitation and corrosion. An off-spec trim changes the behavior of the whole valve.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need a new valve or to repair the one you have?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote control valves](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20control%20valve) [Repair my valve](https://its-ve.com/en/services/control-valve-repair/)