# Fisher severe-service control valves: cavitation, noise and flashing

> Fisher anti-cavitation trims (Cavitrol, NotchFlo, Micro-Flat), low-noise trims (Whisper) and steam conditioning (TBX) for high pressure drop. Selection…

Source: https://its-ve.com/en/products/final-control/control-valves/severe-service/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- [Control valves](https://its-ve.com/en/products/final-control/control-valves/)
- Severe service

[Control valves](https://its-ve.com/en/products/final-control/control-valves/)

Final control · Control valves

# Fisher control valves for severe service

Cavitation, aerodynamic noise, flashing and particles: the trims that stage the pressure drop and keep the valve in service where others fail on schedule.

[Quote control valves for severe service](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20severe-service%20control%20valve) [Repair my control valve](https://its-ve.com/en/services/control-valve-repair/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is severe service?

Severe service is the set of applications where the pressure drop, the velocity or the fluid punish the control valve beyond what a standard trim can take: cavitation, flashing, aerodynamic noise, particles and high-temperature steam.

Severe-service trims stage the pressure drop and split the gas flow into multiple jets. The choice is made at sizing, when the calculation shows choked flow, cavitation or noise above the limit.

- Pressure drop staged in steps
- Anti-cavitation: Cavitrol, NotchFlo, Micro-Flat
- Noise: Whisper NXG and NXV
- Steam: TBX conditioning

Models

## Fisher severe-service trims and valves

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

Cavitrol III

### Fisher Cavitrol III anti-cavitation trim

Staged cage that splits the pressure drop to avoid cavitation.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100196x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Cavitrol%20III)

Fisher

Cavitrol Hex

### Fisher Cavitrol Hex trim

Anti-cavitation trim for segmented ball rotary valves.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101497x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Cavitrol%20Hex)

Fisher

Micro-Flat

### Fisher Micro-Flat cavitation trim

Low-flow trim for high pressure drops in liquids.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102702x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Micro-Flat)

Fisher

NotchFlo DST

### Fisher NotchFlo DST control valve

Anti-cavitation for dirty liquids with entrained particles.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/D103036X012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20NotchFlo%20DST)

Fisher

Whisper NXG

### Fisher Whisper NXG low-noise trim

Aerodynamic noise attenuation in gas and steam.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100021x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20NXG)

Fisher

Whisper NXV

### Fisher Whisper NXV low-noise trim

Noise attenuation with optimized flow paths.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104761x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Whisper%20NXV)

Fisher

TBX

### Fisher TBX steam conditioning valve

Pressure reduction and desuperheating in one valve.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103052x012.pdf) [Severe service](https://its-ve.com/en/products/final-control/control-valves/severe-service/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20TBX)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## Which phenomenon, which trim?

Cavitation: the liquid accelerates in the vena contracta, its pressure falls below vapor pressure, bubbles form and, as pressure recovers downstream, they collapse against the trim and the body. It is fought with staged trims (Cavitrol III, Micro-Flat), with designs for dirty liquids (NotchFlo DST) and with trims for rotary valves (Cavitrol Hex).

Flashing: the downstream pressure stays below vapor pressure, the bubbles do not collapse and the fluid leaves as a high-velocity two-phase mixture that erodes the outlet. The answer is an angle body with expanded outlet and hardened materials, not an anti-cavitation trim. Noise: high-velocity gas generates aerodynamic noise; Whisper trims split the flow into multiple passages to attenuate it. Steam: TBX conditioning valves reduce pressure and desuperheat in one unit.

### Constructions and trim

- ### Anti-cavitation in liquids Cavitrol III and Micro-Flat stage the pressure drop; NotchFlo DST does it in liquids with particles; Cavitrol Hex serves segmented ball rotary valves.
- ### Low noise in gas and steam Whisper NXG and NXV attenuate aerodynamic noise with flow paths that split the jet into multiple passages.
- ### Flashing and erosion Angle bodies with expanded outlets, liners and hardened materials that slow the two-phase jet and protect the outlet.
- ### Steam conditioning TBX and desuperheaters that reduce pressure and lower steam temperature to protect downstream equipment.

Applications

## Where severe service appears

- Pump recirculation and minimum-flow lines
- Pressure let-down, flare vents and separator dump
- Boiler feedwater at startup and recirculation
- Turbine bypass, soot blowers and high-temperature steam
- Compressor anti-surge and high-velocity gas vents

### Why it is chosen

- Trims designed for the specific phenomenon: cavitation, flashing, noise or particles
- Staged pressure drop that keeps local pressure above vapor pressure
- Noise reduction without sacrificing capacity
- Fewer unplanned outages and less damage to downstream piping

### Worth weighing

- Diagnosis rules: an anti-cavitation trim in flashing service erodes, and an erosion trim in cavitating service pits
- A staged trim only protects if it is rebuilt with genuine parts to the original tolerances

ITS de Venezuela

## What ITS does in severe service

We review the service conditions to confirm the phenomenon, quote the right trim and genuine parts, restore staged trims in the shop and diagnose in the field with FIELDVUE. If a valve fails on schedule, the problem is usually in the selection, not the repair.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20severe-service%20control%20valve)
- ### Trim restoration Engineering assessment of plug, seat and cage before rebuilding.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.

- [Fisher OEM parts](https://its-ve.com/en/products/final-control/fisher-oem-parts/)

Resources

## To size it and go deeper

The sizing guide, the technical library and the manufacturer’s official documentation.

- Guide ### How to size a control valve Service data, Cv, choked flow, characteristic and the mistakes that cost capacity and control.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Service ### Repair and trim restoration Shop in Puerto Ordaz and field service to bring the valve back to specification.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and the Control Valve Handbook on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
How do I know whether my valve cavitates or flashes?
By the downstream pressure against the liquid’s vapor pressure: if it stays above, the bubbles collapse and there is cavitation (pitted damage on trim and body); if it stays below, the fluid leaves two-phase and there is flashing (smooth erosion at the outlet). The sizing calculation anticipates it.

Does an anti-cavitation trim solve noise in gas?
No. Cavitation is a liquid phenomenon; aerodynamic noise belongs to gas and steam and is attenuated with low-noise trims such as Whisper. Each phenomenon has its trim.

Type

## All control valve types

### Globe valves

### Angle valves

### Segmented ball valves

### Three-way valves

### Full-bore ball valves

### Eccentric plug valves

### High-performance butterfly valves

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need control valves for severe service, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote control valves for severe service](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20severe-service%20control%20valve) [Repair my control valve](https://its-ve.com/en/services/control-valve-repair/)