# Fisher pressure regulators

Regulators for gas, steam and liquids: pressure-reducing, backpressure and slam-shut safety devices.

[Quote regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20pressure%20regulator) [Regulator service](https://its-ve.com/en/services/regulators-and-relief/)

## Self-operated regulator or pilot-operated control valve?

A self-operated regulator takes its energy from the process itself: a diaphragm and a spring compare the controlled pressure with the set point and move the plug with no external signal or air. It is simple, fast and needs no instrumentation.

When remote operation, set-point changes or integration with the control system are needed, a control valve with a positioner is used. Pilot-operated regulators cover the middle ground, with more accuracy and capacity than direct-operated ones.

## Fisher pressure regulators

Stable pressure using the energy of the process itself.

A self-operated regulator compares the controlled pressure with its set point and moves the plug without an external signal or air supply. Every regulator combines three elements: a restricting element (plug and orifice), a measuring element (the diaphragm that senses pressure) and a loading element (the spring or pilot that sets the target).

Depending on its function it holds the downstream or upstream pressure, feeds burners, reduces steam or shuts off the supply when pressure leaves its limits. Emerson groups the Fisher catalog into pressure reducing regulators, back pressure regulators, slam-shut devices and steam regulators; pilot-operated regulators for natural gas and fuel gas valves are presented here as well.

### What’s your challenge?

A poorly sized regulator hunts, is noisy or fails to reach set pressure when demand changes.

### What’s your opportunity?

Selected by function, flow and spring range, it holds pressure without instrumentation or external power.

### Pressure reducing regulators

**Pressure reducing regulators.** They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

- MR95
- 67C
- 67D
- 627
- MR105

### Pilot-operated regulators for natural gas

**Pilot-operated regulators for natural gas.** A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

- EZH / EZHSO
- EZR
- 1098-EGR
- 99

### Back pressure regulators and relief

**Back pressure regulators and relief.** They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

- MR98
- MR108
- 63EG
- 1808 / 1808A
- 1805
- 289

### Fuel gas valves

**Fuel gas valves.** They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

- 119EZ
- 119EZS
- 119

### Slam-shut devices

**Slam-shut devices.** They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

- OSE
- VS100
- EZROSX
- 299HV

### Steam regulators

**Steam regulators.** They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.

- 92B
- 92S
- 92C
- MR95

Fisher models

## Regulators by model

Each model with its official technical bulletin, which you can read right here, and a quote one click away.

Find a model
- Pressure-reducing regulator ### Fisher 64 Adjustable regulators that cut LP-gas tank pressure to an intermediate level. The 64SR adds internal relief, and the 64KB has a PTFE diaphragm protector suited to anhydrous ammonia. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-64-and-67c-series-regulators-instruction-manual-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2064)
- Pressure-reducing regulator and vacuum service equipment ### Fisher 66 Direct-operated regulators for precise control of low-pressure industrial gases, as in burners and tank blanketing, plus vacuum service equipment as vacuum regulators or vacuum breakers. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100114x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2066)
- Instrument supply pressure-reducing regulator ### Fisher 67C Direct-operated regulators and filter regulators that deliver steady reduced pressure to pneumatic and electropneumatic controllers and other instruments. Suitable for most air or gas service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-67c-series-instrument-supply-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2067C)
- Pressure-reducing regulator ### Fisher 67C Compact-body high-pressure regulator for LP-gas in liquid or vapor service, offered with wrench, handwheel, calibrated dial or tamper-resistant fixed spring adjustment. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-64-and-67c-series-regulators-instruction-manual-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2067C)
- Pressure-reducing regulator ### Fisher 67D Direct-operated regulators and filter regulators that deliver constant reduced pressure of gaseous fluids to pilot-operated controllers and other pneumatic instrumentation. Compact design. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-67d-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2067D)
- Pressure-reducing regulator ### Fisher 99 Gas regulator with a Type 61 pilot mounted on the actuator casing, for distribution, industrial and commercial use. It accepts inlet pressures up to 1000 psig (69 bar). [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-99-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2099)
- Fuel gas switching valve ### Fisher 119 Valve for on-off or throttling control of noncorrosive gases at low pressure. The 119EZ and 119EZS versions feed natural-draft burners and tune the opening speed for safe ignition of the main flame. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/data-sheets-119-series-fuel-gas-valve-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20119)
- Pressure-reducing regulator ### Fisher 133 Direct-operated regulator that supplies gas to furnaces, burners and other industrial and commercial appliances. Its balancing system keeps pressure steady despite varying inlet pressure. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-133-series-direct-operated-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20133)
- Pilot-operated pressure-reducing regulator ### Fisher 299H Series of pilot-operated regulators for distribution, industrial and commercial use, with inlet pressures up to 175 psi. Versions are available with supply shutoff or with internal relief for thermal expansion. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-299h-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20299H)
- Fuel gas pressure regulator ### Fisher 310A Regulator for high-pressure, fast-response duty such as fuel gas supply to a gas turbine. It carries a Type 32A pilot and works for pressure reducing or wide-open monitoring, with high capacity. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-310a-32a-pressure-reducing-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20310A)
- Pressure-reducing regulator ### Fisher 627 Direct-operated pressure-reducing regulators for low and high-pressure systems, suitable for natural gas, air and other gases. Performance varies with the construction selected. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-627-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20627)
- Pilot-operated pressure-reducing regulator ### Fisher 627F Pilot-operated regulator intended for fixed-factor pressure measurement. It ships with a factory-installed 6351F pilot and external registration, so it needs a downstream control line. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-627f-pilot-operated-pressure-reducing-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20627F)
- Pressure-reducing regulator ### Fisher 630 Spring-loaded, direct-operated regulator in NPS 1 and 2 bodies for natural gas, air and other gases. Used as a first-stage farm-tap or high-pressure industrial regulator, and convertible to a relief valve in the field. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-630-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20630)
- Panel-mounted loading regulator ### Fisher 670 Compact, rugged unit used mainly to load pressure-balanced gas regulators by hand. It also gives manual control of control valves fitted with diaphragm actuators. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-670-series-panel-mounted-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20670)
- Automatic changeover manifold ### Fisher 749B High-capacity assembly for commercial and industrial use that switches by itself from the supply cylinder to the reserve one when gas runs out. It combines two 64 Series regulators and a Type 803 direct indicator. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-749b-and-r130-changeover-manifolds-instruction-manual-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20749B)
- Pressure-reducing regulator ### Fisher 912 UL-listed direct-operated, spring-loaded regulator for LP-gas service and industrial installations, with limited-capacity internal relief across the diaphragm. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-912h-912n-y200h-y200n-and-r922n-lp-gas-regulators-instruction-manual-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20912)
- Pressure-reducing regulator ### Fisher 912N Direct-operated, spring-loaded regulator for service and industrial installations. Its limited-capacity internal relief bleeds excess pressure through the vent. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-912n-series-pressure-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20912N)
- Pilot-operated pressure-reducing regulator ### Fisher 1098-EGR Regulators for pressure control in natural gas distribution, fuel supply to boilers, furnaces and mixers, and large commercial buildings. They also serve in plant air and liquid service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletin-1098-egr-and-1098h-egr-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201098-EGR)
- Low-pressure gas blanketing regulator ### Fisher 1190 Pilot-operated pressure-reducing valve with a supply pressure regulator, used for very accurate control of gas blanketing systems at very low pressures. It uses a quick-change trim package. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-1190-low-pressure-tank-blanketing-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201190)
- Vapor recovery regulator ### Fisher 1290 Self-contained, pilot-operated regulator system for handling blanketing gas in vapor recovery schemes. It includes a quick-change trim package to ease maintenance. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-1290-vapor-recovery-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201290)
- High-pressure regulator ### Fisher 1301F 1301G Self-operated high-pressure regulators that reduce gas for use as pilot supply pressure in pilot-operated regulators or loading pressure in pressure-loaded regulators. Also used as general high-pressure reducers. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-1301-series-high-pressure-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201301F%201301G)
- Direct-operated pressure-reducing regulator ### Fisher 1305 Direct-operated regulators that resist hydrate formation and freeze-up, used on high-pressure lines from wellheads and separators. Suitable for natural gas, air, propane and other gases. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-1305-series-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201305)
- High-pressure instrument supply system ### Fisher 1367 System of filters, regulators and relief valves that takes pressure of up to 2000 psig and reduces it to the controlled pressure a pneumatic instrument needs, with overpressure protection included. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/data-sheets-1367-high-pressure-instrument-supply-system-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201367)
- Tank blanketing valve ### Fisher ACE95 Stainless steel pilot-operated valve for accurate pressure control in low-pressure blanketing systems, with a very large rolling-diaphragm actuator and a single adjusting screw. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ace95-and-ace95sr-tank-blanketing-valves-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20ACE95)
- Tank blanketing valve ### Fisher ACE95Jr Direct-operated stainless steel valve for low-pressure blanketing. Its oversized diaphragm actuator makes it highly sensitive to changes in tank pressure. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ace95jr-tank-blanketing-valve-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20ACE95Jr)
- Tank blanketing valve ### Fisher ACE95Sr Self-contained, fully balanced, pilot-operated valve for accurate pressure control in tank blanketing systems. It helps control emissions and protects against atmospheric contamination. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ace95-and-ace95sr-tank-blanketing-valves-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20ACE95Sr)
- Residential gas regulator with safety shutoff ### Fisher B NG Direct-acting, spring-loaded regulator with reinforced safety for residential, commercial and industrial use. A shutoff valve trips on excess flow or pressure drop and can be reset manually. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104474x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20B%20NG)
- Throttle valve for station bypass ### Fisher BLE BLX Throttle valves that act as a bypass in transmission stations, reducing pressure up to 100 bar. The BLX version includes an OS2 release relay that cuts off flow on outlet overpressure. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/ncablex0410en_blex_bul.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20BLE%20BLX)
- Pressure-loaded pressure-reducing regulator ### Fisher CP200 Series of pressure-loaded regulators for commercial and institutional installations, with many connection sizes, outlet pressures and orifices. Its accurate control suits fixed-factor measurement applications. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-cp200-series-commercial-industrialpressure-loaded-pressure-reducing-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CP200)
- Pressure-loaded pressure-reducing regulator ### Fisher CP400 Series of pressure-loaded regulators for light industrial and commercial installations, with accurate control suited to fixed-factor measurement. Options include several connections, materials, orifices and overpressure protection. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-cp400-series-commercial-industrial-pressureloaded-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CP400)
- Pressure-reducing regulator ### Fisher CS200 Direct-operated, spring-loaded regulator for commercial and light industrial installations. The actuator rotates a full 360 degrees through a union ring on the body, easing installation and maintenance. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-cs200-series-commercial-industrial-pressurereducing-regulators-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CS200)
- Pressure-reducing regulator ### Fisher CS400 Direct-operated, spring-loaded regulator for commercial and light industrial applications, with several body, connection and orifice sizes and overpressure protection options. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/fisher-cs400-series-commercial-industrial-pressure-reducing-regulators-bulletin-d103134x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CS400)
- Pressure-reducing regulator ### Fisher CS800 Direct-operated, spring-loaded regulator for commercial and light industrial applications, with several body and orifice sizes, internal or external registration and overpressure protection options. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-cs800-series-commercialindustrial-pressure-reducing-regulators-for-north-america-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CS800)
- Pressure-reducing regulator ### Fisher CSB400 Direct-operated, spring-loaded regulator for commercial and light industrial sites, offered in several body sizes, with internal or external pressure registration and overpressure protection options. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-csb400-series-commercial-industrial-pressurereducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CSB400)
- Pressure-reducing regulator ### Fisher CSB600 Direct-operated, spring-loaded regulator with many body, connection and outlet pressure options using external registration, plus overpressure protection alternatives, including slam-shut. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-csb600-series-commercial-industrial-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CSB600)
- Pressure-reducing regulator ### Fisher CSB700 Direct-operated, spring-loaded regulator built for many pressure-reducing duties, with a range of connections and outlet pressures using external registration, and optional overpressure protection. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-csb700-series-commercial-industrial-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CSB700)
- Pressure-reducing regulator ### Fisher EZH y EZHSO Pilot-operated, balanced, soft-seated regulators for high-pressure city-gate stations, large distribution systems and power plant feeds. EZH is spring-to-close and EZHSO is spring-to-open. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/data-sheets-ezh-and-ezhso-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZH%20y%20EZHSO)
- Pilot-operated pressure-reducing regulator for low pressure ### Fisher EZL Pilot-operated, pressure-balanced, soft-seated regulator for natural gas distribution in district stations and commercial or industrial meter sets. It gives low differential and tight shutoff. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ezl-pressure-reducing-regulator-for-low-differential-pressure-applications-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZL)
- Pressure-reducing regulator ### Fisher EZR Pilot-operated regulator for natural gas networks and industrial or commercial sites, with tight shutoff. The EZROSX version adds a slam-shut device that reacts to over or under pressure. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ezr-series-pressure-reducing-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZR)
- Pressure-reducing regulator ### Fisher HSR Direct-operated, spring-loaded regulator for natural, manufactured or liquefied gas in residential, commercial and industrial use. Internal relief limits overpressure and it meets ANSI B109.4/CGA 6.18. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-hsr-pressure-reducing-regulator-forresidential-commercial-or-industrial-applications-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20HSR)
- Pressure-reducing regulator ### Fisher HSRL UL-listed second-stage regulator for two-stage LP-gas systems, with capacity up to 2,600,000 BTU/hr (29.27 SCMH), suited to commercial applications. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-hsrl-series-lp-gas-regulators-asia-pacific-only-instruction-manual-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20HSRL)
- Pressure-reducing regulator ### Fisher LSR High-capacity self-operated regulator with a balanced port and optional integral slam-shut, for district stations and industrial loads such as driers, furnaces, boilers and burners. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/d104646x012-bulletin-ls200-series-direct-operated-regulators-north-america-only-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20LSR)
- Slam-shut safety valve ### Fisher OSE Slam-shut valve that quickly cuts gas flow on overpressure or underpressure, with positive shutoff and high shock and vibration resistance. Top entry allows in-line maintenance. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-ose-slam-shut-valve-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20OSE)
- LP-gas first-stage regulator ### Fisher R122H First-stage regulator for domestic two-stage LP-gas systems, UL listed and suited to tight installations. Stainless steel internal parts give a recommended replacement life of 20 years. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-r122h-first-stage-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R122H)
- Changeover manifold regulator assembly ### Fisher R130 Changeover assembly made of two 67C regulators and a special gauge that shows when the supply cylinder has switched to the reserve. The R130-20 delivers 45 psig on supply and 30 psig on reserve. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-749b-and-r130-changeover-manifolds-instruction-manual-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R130)
- LP-gas second-stage regulator ### Fisher R222 UL listed regulator for two-stage LP-gas systems that lowers the first-stage pressure, usually 10 psig, to 11 inches water column. Its compact size suits tight fit installations. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-r222-second-stage-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R222)
- LP-gas first-stage regulator ### Fisher R222H UL listed first-stage regulator for LP-gas systems with a small footprint for underground tanks or limited dome space. It offers multiple end connections, adjustable springs and corrosion resistant materials. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-r222h-first-stage-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R222H)
- Integral two-stage regulator ### Fisher R232A UL listed regulator for LP-gas systems with small domestic loads that reduces tank pressure to 11 inches water column through an integral two-stage system. Its compact size suits tight installations. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-r232a-integral-two-stage-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R232A)
- Integral two psig service regulator ### Fisher R232E UL listed regulator for LP-gas systems with small domestic loads that reduces tank pressure to 2 psig through an integral system. Its compact size suits tight installations. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-r232e-integral-two-psig-service-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R232E)
- Pressure-reducing regulator ### Fisher R622 Direct-operated, spring-loaded regulator for economical pressure reduction in residential, commercial and industrial uses. It works with natural, manufactured or liquefied petroleum gas. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-r622-pressure-reducing-regulator-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R622)
- LP-gas second-stage regulator ### Fisher R622 R642 R652 UL-listed second-stage regulators that reduce the outlet pressure of a first-stage regulator in domestic installations. The R622 includes a relief valve and screened vent; the R642 and R652 have an angle body. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d450136t012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R622%20R642%20R652)
- 2-PSI LP-gas service regulator ### Fisher R622E R652E UL-listed regulators for 2-PSI LP-gas systems, installed after the first-stage regulator. They supply about 2 psig to a line regulator inside the building and carry a white closing cap for identification. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-r622e-and-r652e-2-psi-014-bar-service-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R622E%20R652E)
- Pressure-reducing regulator ### Fisher R622H UL-listed (Underwriters Laboratories) first-stage regulator for two-stage LP-gas systems. It reduces tank pressure to 10 psig (0.69 bar) ahead of the second-stage regulator. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-r622h-first-stage-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R622H)
- Pressure-reducing regulator ### Fisher R632A UL-listed integral two-stage regulator for LP-gas systems, taking tank pressure down to 11 inches w.c. (27.4 mbar), with screened vents on both stages. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-r632a-lp-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R632A)
- Integral two psig service regulator ### Fisher R632E UL listed regulator for two psig service LP-gas systems that reduces tank pressure to 2 psig in a single unit. The first-stage vent points downward and the second-stage vent sits over the outlet. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-r600-and-hsrl-series-lp-gas-regulators-instruction-manual-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20R632E)
- Second-stage LP gas regulator ### Fisher RJ622 Second-stage regulators that reduce the outlet pressure from a first-stage regulator in domestic LP gas installations. Versions come in straight or angle bodies, and with settings down to 2 psig. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-rj600-series-instruction-manual-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20RJ622)
- Pressure-reducing regulator ### Fisher S402Y Direct-operated, spring-loaded regulator for corrosive environments in residential and small commercial uses. It reduces gas distribution pressures to a range from 4.5 inches w.c. to 2.5 psig. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-s402y-direct-operated-pressure-reducing-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20S402Y)
- Tank blanketing regulator ### Fisher T205 Spring-loaded, direct-operated regulator that holds a slight positive pressure over the stored liquid. This keeps it from vaporizing to atmosphere, lowers its combustibility and protects it from oxidation and contamination. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-t205-series-tank-blanketing-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20T205)
- Balanced tank blanketing regulator ### Fisher T205B Direct-operated regulator with a fully balanced plug that reduces sensitivity to inlet pressure. Its large diaphragm accurately controls tank pressure at low settings in blanketing systems. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/regulators/fisher/others/documents/PRM-BLT-T205B-Balanced-Tank-Blanketing-Regulator-Bulletin-VCBUL-10990-EN.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20T205B)
- Vacuum breaker ### Fisher T205VB Vacuum breaker for precise control in small-capacity, low-pressure service where a rise in vacuum must be limited. It shares spare parts with other products in the T205 Series. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-t205vb-series-vacuum-breakers-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20T205VB)
- Tank blanketing vapor recovery regulator ### Fisher T208 Direct-operated regulator that senses a rise in vessel pressure and vents the excess to a vapor recovery system. It can also serve as a backpressure regulator or relief valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-t208-series-tank-blanketing-vaporrecovery-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20T208)
- Vacuum regulator ### Fisher T208VR Direct-operated vacuum regulator for cases where a decrease in vacuum must be limited, such as between a tank and the vacuum source to control tank vacuum. It has a tamper-resistant adjustment. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-t208vr-series-vacuum-regulator-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20T208VR)
- Pressure-reducing regulator ### Fisher Type B Economical direct-operated, spring-loaded regulator for residential, commercial and industrial pressure reduction. It fits cabinets or underground modules and offers an integral slam-shut option. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-b-nv-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Type%20B)
- Slam-shut safety valve ### Fisher VS100 Slam-shut family that cuts gas to the downstream system when outlet pressure rises above or falls below the set limits. The VS110 uses the VSX4 device and the VS120 the VSX8. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-vs100-series-slam-shut-device-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20VS100)
- Pressure-reducing regulator ### Fisher Y600A Series of regulators with a large diaphragm area that gives good accuracy at low-pressure settings. The Y600A and Y600AR include a pitot tube for added capacity; the Y600AM uses external registration. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-y600a-series-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y600A)
- Vacuum service and relief equipment ### Fisher Y610A Y611A Y612A Family for vacuum and relief service: the Y610A works as a vacuum breaker, the Y611A as a vacuum breaker or relief valve and the Y612A as a vacuum regulator. It allows fine control at low pressure settings. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-y610a-y611a-and-y612a-series-vacuum-service-equipment-and-relief-valves-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y610A%20Y611A%20Y612A)
- Gas blanketing regulator ### Fisher Y692 Self-operated regulator with internal registration, requiring no downstream control line. It is used for accurate control of very low-pressure blanketing systems, keeping positive pressure in the vessel. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-y692-gas-blanketing-regulator-system-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y692)
- Vacuum breaker ### Fisher Y692VB Limits a rise in vacuum within a system. When vacuum exceeds the value sensed on the diaphragm, it opens and admits atmosphere or positive pressure to bring the controlled vacuum back to its original setting. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-y692vb-series-vacuum-breaker-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y692VB)
- Gas blanketing regulator ### Fisher Y693 Direct-operated regulator for accurate pressure control in low-pressure gas blanketing systems. Its balanced plug gives accuracy comparable to that of a pilot-operated regulator. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-y693-gas-blanketing-regulator-system-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y693)
- Vacuum regulator ### Fisher Y696VR Vacuum regulators for cases where a decrease in vacuum must be limited, for example between a tank and the vacuum source. When vacuum drops, the diaphragm opens the seat and returns the system to set point. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-y696vr-series-vacuum-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y696VR)
- Pressure-reducing regulator for liquids ### Fisher 92W Regulator for liquid service fitted with a Type 6492H or 6492L pilot. Downstream pressure acts on the main valve pistons and then on the pilot diaphragm. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/data-sheets-92w-pressure-reducing-liquid-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092W)
- Liquid pressure-reducing regulator ### Fisher 627W Direct-operated pressure-reducing regulators for liquid service. They come in three body sizes, NPS 3/4, 1 and 2, and in construction materials matched to the application. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/isolation-valves/documents/data-sheets-627w-and-627wh-direct-operated-pressure-reducing-liquid-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20627W)
- Pressure-reducing regulator for liquids ### Fisher LR125 Pilot-operated regulator for liquid service with smooth operation, tight shutoff and long life, even in dirty service. Its internal metal plug and inlet strainer protect the seat from debris. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-lr125-pressure-reducing-liquid-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20LR125)
- Liquid pressure-reducing regulator ### Fisher MR105 High-capacity, direct-operated regulator for liquid, air and gas. It suits cases needing fast response or fluids carrying impurities, such as lube oil, cooling water and pump bypass. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-mr105-direct-operated-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR105)
- Steam pressure-reducing valve ### Fisher 92B Steam reducing valve for dirty environments with stable control. It serves as the main pressure reducer in industrial heating on heat exchangers, evaporators, digesters and reactors. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92b-pressure-reducing-valve-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092B)
- Self-operated steam regulator ### Fisher 92C Cost-effective steam pressure reducer, with a Type 6392 pilot that uses inlet pressure as its operating medium, or without pilot as a pressure-loaded regulator for remote setpoint adjustment. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92c-self-powered-control-valve-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092C)
- Steam pressure-reducing valve ### Fisher 92EZ Steam pressure-reducing valve for process heating such as heat exchangers, evaporators, digesters and reactors. It copes with dirty environments and its trim is replaced using a drop-in kit. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/fisher-type-92ez-pressure-reducing-valve-bul-d104686x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092EZ)
- Pilot-operated steam regulator ### Fisher 92S Piston-actuated self-operated valve for high-cycle steam, with lapped seating surfaces and bellows-sealed pilots. It reaches 250 psig (17.2 bar) and 650°F (343°C). [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92s-pilot-operated-steam-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092S)
- Regulator pilot ### Fisher 61 Series of pilots for 1098-EGR and EZL regulators, with counterparts for the 99 Series. Styles cover low, high and extra-high pressure, with different proportional bands and standard or high-temperature materials. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-61-series-pilots-for-pilot-operated-pressurereducing-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2061)
- Regulator pilot ### Fisher 6350 6360 Pilots paired with several main valves in pressure-reducing, relief or back-pressure applications. All work in gas service and, except the 6351, in liquid service as well. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/manuals-6350-series-pilots-for-pilot-operated-pressurereducing-regulators-instruction-manual-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%206350%206360)
- Direct-operated pressure-reducing regulator ### Fisher MR95 Compact, large-capacity regulator for superheated steam, steam tracing, nitrogen purging, boiler feed water, process chemicals, cooling water, autoclaves and pneumatic supply. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletin-mr95-series-industrial-pressure-regulators-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR95)
- Sanitary pressure-reducing regulator ### Fisher SR5 Compact, large-capacity, self-operated regulator for sanitary applications in pharmaceutical, biotech and food. Offered in NPS 1/2 to 3 with Tri-Clamp connections, for steam, liquid or gas. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-sr5-sanitary-pressure-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20SR5)
- Back-pressure regulator and relief valve ### Fisher 63EG Pilot-operated relief valve for liquid and gas service, also suited to back-pressure or bypass throttling. Its quick-change trim speeds up maintenance and it accepts wireless position monitors. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-63eg-relief-valve-orbackpressure-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2063EG)
- Pilot-operated backpressure regulator ### Fisher 63EG-98HM Relief valve or backpressure regulator for gas, liquid or steam. With EPDM or FFKM it handles up to 550°F (288°C) with Class VI shutoff, and other elastomers are available for corrosive service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/fisher-type-63eg-98hm-pilot-operated-relief-valve-bulletin-d102628x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2063EG-98HM)
- Vapor recovery regulator ### Fisher 66R Responds to changes in blanket gas pressure and throttles open or closed to control the gas leaving the vessel, working at very low set points. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-66r-and-66rr-low-pressure-relief-valves-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2066R)
- Relief valve or backpressure regulator ### Fisher 289 Spring-loaded relief valves that act as downstream pressure regulators to protect the system from overpressure. A large diaphragm gives sensitivity at low settings, and they are not ASME safety relief valves. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d100154x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20289)
- Pilot-operated relief valve or backpressure regulator ### Fisher 289P Pilot-operated relief valve that protects downstream systems from overpressure on natural gas, air, propane or other non-corrosive media. It needs very little buildup over set pressure to open fully. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-289p-pilot-operated-relief-valve-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20289P)
- Backpressure regulator and relief valve ### Fisher 1805 Relief valves for farm taps, installed between first-stage and second-stage regulators, suited to natural gas, air or propane, with relief settings from 5 to 125 psig (0.34 to 8.6 bar). [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-1805-series-relief-valves-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201805)
- Pilot-operated relief valve ### Fisher 1805P Low-cost relief valve made of a 1805P main valve and a 6358 pilot, in NPS 2, with settings from 10 to 100 psig (0.69 to 6.9 bar) in three ranges, adjusted at the pilot screw. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-type-1805p-pilot-operated-relief-valve-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201805P)
- Pilot-operated backpressure regulator ### Fisher 1808 y 1808A Compact backpressure regulators or relief valves in globe (1808) or angle (1808A) body, used to hold pressure on oil and gas separators and in gas distribution systems. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-1808-and-1808a-pilot-operated-relief-valves-or-backpressure-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201808%20y%201808A)
- Pilot for backpressure regulators ### Fisher 6365 y 6358 Pilots that pair with several main valves in relief and backpressure applications and work in both gas and liquid service. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/bu-content/general/fisher/documents/PRM-IOM-6365-6358-Series-Pilots-Instruction-Manual-VCIMD-11393-EN.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%206365%20y%206358)
- Backpressure regulator ### Fisher CT88 Holds backpressure on LACT custody-transfer skids so the positive-displacement pump or Coriolis meter can measure accurately and upstream skid equipment stays protected. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ct88-backpressure-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20CT88)
- Pilot-operated relief valve or backpressure regulator ### Fisher EZR Pilot-operated unit that protects against overpressure in city gate and district stations, or works as a backpressure regulator in commercial and industrial use. It runs smoothly and quietly, even in dirty service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ezr-relief-valve-or-backpressure-regulator-bulletin-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZR)
- Relief valve or backpressure regulator for liquids ### Fisher LR128 Pilot-operated unit for liquid service that works as a relief valve or backpressure regulator, with smooth operation and tight shutoff. An internal strainer keeps large particles out of the main valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-lr128-relief-valve-orbackpressure-liquid-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20LR128)
- Back-pressure and relief regulator ### Fisher MR98 Series for back-pressure or relief duty in liquid, gas, air and steam service, with direct-operated spring-loaded models. The D versions add pressure loading to hold differentials or adjust setpoint remotely. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-mr98-series-backpressure-regulators-relief-and-differential-relief-valves-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR98)
- Direct-operated back-pressure regulator ### Fisher MR108 High-capacity, general-purpose back-pressure regulator for liquid, air and gas. It suits lube oil systems and applications where response speed, minimum differential or impure fluids matter. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-mr108-direct-operated-backpressure-regulators-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR108)
- Sanitary backpressure regulator ### Fisher SR8 Compact, large-capacity backpressure regulator for applications where sanitary design is essential, such as pharmaceutical, biotech and food. Fits Tri-Clamp connections in NPS 1/2 to 3 for steam, liquid or gas. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-sr8-sanitary-backpressure-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20SR8)
- Vapor recovery regulator ### Fisher Y696 Direct-operated regulator with internal registration and no downstream control line. It senses rising vessel pressure and vents the excess to a vapor recovery or disposal system. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-y696-vapor-recovery-regulator-bulletin-fisher-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20Y696)

Manufacturer photos and technical bulletins. Fisher and FIELDVUE are marks of Emerson.

Models

## Product pages

Description, features and a link to the manufacturer’s official documentation.

Fisher

MR95

### Pressure regulator

Compact, direct-operated, high-capacity pressure-reducing regulator designed for a wide variety of industrial services: superheated steam, steam injection and tracing, nitrogen purge, boiler feedwater, process chemicals, cooling water and fuel lines, among others.

Check availability

Fisher

119EZ

### Fuel gas valve

Fuel gas valve for natural-draft burners in oil and gas applications, built on the compact, proven Type 119 platform with more than 25 years of service.

Check availability

Applications

## Where they are used

Superheated steam, steam injection and tracing, nitrogen purge, boiler feedwater, process chemicals, cooling water and fuel lines.

In direct-reduction plants and gas production, regulators are built into regulation racks designed for the flow and pressure of each consumer.

Brands

## Brands in this category

- [Fisher Control valves, FIELDVUE, regulators, OEM parts](https://its-ve.com/en/brands/fisher/)

Service

## Services for this equipment

What we do on this equipment in the shop and in the field.

- ### Regulators and relief Maintenance of pressure regulators and relief devices.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.

Projects

## Documented work

Steel

### Lime Plant — SIDOR

Client: API Int'l / SIDOR

Design, Engineering and Construction of a Natural Gas Regulation Rack

Oil & Gas

### Corocoro Project

Client: VHICOA

Rebuild, Metrology and Commissioning of Pressure Regulators

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
Self-operated regulator or pilot-operated control valve?
A self-operated regulator uses process energy and needs no signal or air: it is simple and fast. A control valve with a positioner allows remote operation, set-point changes and integration with the control system. Pilot-operated regulators offer more accuracy and capacity than direct-operated ones.

What is a slam-shut?
It is a safety shutoff device that cuts the gas supply quickly and completely when downstream pressure goes outside the set limits. It is reset manually once the cause is corrected and protects equipment and burners downstream of the regulator.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need a regulator or rack maintenance?

Give us the fluid, inlet and outlet pressures, flow and connection size, or the nameplate model.

[Quote regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20pressure%20regulator) [Regulator service](https://its-ve.com/en/services/regulators-and-relief/)