# Fisher pilot-operated regulators for natural gas

For gas transmission, distribution and supply stations where flow is high and outlet pressure must stay steady at any demand.

[Quote pilot-operated regulators for natural gas](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZH%20pilot-operated%20regulator) [Regulators](https://its-ve.com/en/products/final-control/regulators/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a pilot-operated regulator?

A pilot-operated regulator uses a small regulator, the pilot, to drive a main valve. The pilot amplifies slight changes in outlet pressure, which gives more capacity and holds pressure closer to set point than a direct-operated regulator.

That is why it dominates in natural gas: transmission and city gate stations, large-capacity distribution, power plant feeds and fuel gas for boilers and furnaces. The Fisher EZH, EZR and 1098-EGR Series and the Type 99 cover that range.

- A pilot drives the main valve
- EZH, 1098-EGR and 99 with no atmospheric bleed
- EZH: 1500 psig (103 bar) rating on inlet and outlet
- Optional Whisper Trim cage against noise

Models

## Fisher pilot-operated models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

EZH / EZHSO

### Fisher EZH and EZHSO Series regulators

Pilot-operated, pressure-balanced and soft-seated for high-pressure gas transmission; spring-to-close or spring-to-open.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/data-sheets-ezh-and-ezhso-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Pilot-operated regulators for natural gas](https://its-ve.com/en/products/final-control/regulators/pilot-operated-regulators-for-natural-gas/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZH%20%2F%20EZHSO)

Fisher

EZR

### Fisher EZR Series pressure reducing regulator

Accurate, smooth, quiet operation with tight shutoff, even in dirty service.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-ezr-series-pressure-reducing-regulator-bulletin-fisher.pdf) [Pilot-operated regulators for natural gas](https://its-ve.com/en/products/final-control/regulators/pilot-operated-regulators-for-natural-gas/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZR)

Fisher

1098-EGR

### Fisher Types 1098-EGR and 1098H-EGR pressure reducing regulators

Economical, accurate control in gas distribution and fuel gas; also in plant air and liquid service.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletin-1098-egr-and-1098h-egr-pressure-reducing-regulators-bulletin-fisher.pdf) [Pilot-operated regulators for natural gas](https://its-ve.com/en/products/final-control/regulators/pilot-operated-regulators-for-natural-gas/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%201098-EGR)

Fisher

99

### Fisher Type 99 pressure reducing regulator

Type 61 pilot integrally mounted on the actuator casing, for distribution, industrial and commercial use.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-99-pressure-reducing-regulators-bulletin-fisher.pdf) [Pilot-operated regulators for natural gas](https://its-ve.com/en/products/final-control/regulators/pilot-operated-regulators-for-natural-gas/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2099)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The pilot measures downstream pressure and compares it with its spring. When demand increases and pressure falls, the pilot changes the loading pressure on the actuator or diaphragm of the main valve and it opens; as pressure recovers, the pilot returns it toward closure. Because the pilot reacts to very small variations, the main valve covers its full travel with minimal deviation from set point.

In these designs the gas bled by the pilot is routed to the downstream line instead of being vented: for the EZH and the 1098-EGR Emerson states that the pilot-operated system bleeds 100% of the gas to the downstream system. The knife-edged metal plug against a soft seat gives bubble-tight shutoff in dead-end systems, and the optional Whisper Trim cage attenuates noise at the source.

### Constructions and trim

- #### EZH and EZHSO Pressure-balanced and soft-seated. The EZH is spring-to-close to protect downstream assets; the EZHSO is spring-to-open to maintain supply. The manufacturer publishes the same 1500 psig (103 bar) rating on inlet and outlet.
- #### EZR The metal plug deflects particles away from the diaphragm and a stainless steel inlet strainer protects it. With travel indicator and an EZROSX version with integrated slam-shut.
- #### 1098-EGR and 1098H-EGR Top entry: trim is inspected, cleaned and replaced without removing the body from the line. According to the manufacturer it controls at differentials as low as 1 psid (70 mbar).
- #### Type 99 Type 61 pilot mounted on the actuator casing and three pilots to choose from. The manufacturer states inlet pressures up to 1000 psig (69.0 bar).

Applications

## Where they are used

- High-pressure natural gas transmission and city gate stations
- Large-capacity distribution systems and district regulating stations
- Gas feed to turbines and power generation plants
- Fuel gas supply to industrial boilers, furnaces and burners
- Plant air and liquid service with the 1098-EGR

### Why it is chosen

- More accuracy and capacity than a direct-operated regulator of the same size
- EZH, 1098-EGR and Type 99 with no gas bleed to atmosphere: the pilot bleeds downstream
- Tight shutoff with metal plug and soft seat, suitable for dead-end systems
- Options for noise reduction, travel indicator and integrated slam-shut

### Worth weighing

- They need a minimum differential between inlet and outlet for the pilot to fully open the main valve
- Pilot passages are small: on gas carrying solids or liquids, the pilot supply should be filtered and its condition checked at every maintenance

ITS de Venezuela

## What ITS does with pilot-operated regulators

ITS quotes new Fisher pilot-operated regulators, their pilots and their genuine parts (diaphragms, plugs, seats, cages, seals and pilot kits), and services installed stations: disassembly, inspection, soft parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, and field maintenance of regulating trains, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: gas and its composition if it is not natural gas, maximum and minimum inlet pressure, outlet pressure, maximum and minimum flow, temperature, line size and connections, and whether a monitor or slam-shut is required; or the model and serial number from the nameplate.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZH%20pilot-operated%20regulator)
- ### Regulators and relief Maintenance of pressure regulators and relief devices.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Regulators Pressure-reducing, backpressure, fuel gas and slam-shut.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What is a worker-monitor configuration?
It is two regulators in series. The worker controls pressure in normal operation; the monitor, set slightly higher, stays open and takes over if the worker fails open. Emerson notes that combining an EZHSO as worker, which is spring-to-open and favors continuity, with an EZH as monitor, which is spring-to-close and protects assets, brings together the advantages of both failure modes.

How do you choose between direct-operated and pilot-operated?
By accuracy and flow. The direct-operated regulator is simple, robust and economical, and is enough when some pressure drop under load is acceptable. The pilot-operated regulator holds pressure closer to set point and handles larger flows, so it is chosen for gas stations and large consumers. The final decision comes from sizing with the actual pressures and flow.

Regulators

## More regulators families

### Pressure reducing regulators

They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

### Back pressure regulators and relief

They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

### Fuel gas valves

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

### Slam-shut devices

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

### Steam regulators

They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need pilot-operated regulators for natural gas, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote pilot-operated regulators for natural gas](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20EZH%20pilot-operated%20regulator) [Regulators and relief](https://its-ve.com/en/services/regulators-and-relief/)