# Fisher MR95, 67C, 67D and 627 pressure reducing regulators

> Fisher direct-operated pressure reducing regulators: MR95 for steam, water, gases and chemicals; 67C and 67D for instruments; 627 for gas. Quotations.

Source: https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- [Regulators](https://its-ve.com/en/products/final-control/regulators/)
- Pressure reducing regulators

[Regulators](https://its-ve.com/en/products/final-control/regulators/)

Regulators · Fisher

# Fisher pressure reducing regulators

They reduce a high, variable inlet pressure to a steady outlet pressure, with no external signal or power, and follow the demand of the equipment they supply.

[Quote pressure reducing regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR95%20regulator) [Regulators](https://its-ve.com/en/products/final-control/regulators/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a pressure reducing regulator?

A pressure reducing regulator lowers a high, often variable inlet pressure to a lower, steady outlet pressure, automatically and without external power: it opens when demand increases and throttles when demand decreases.

In the direct-operated design, outlet pressure acts on a diaphragm against a spring, and the diaphragm moves the plug: it is the simplest and fastest design. The Fisher MR95 Series is the industrial reference; the 67C and 67D supply instruments and the 627 covers natural gas and air.

- Direct-operated · no external power
- Steam, water, air, gases and chemicals
- MR95: set pressures to 400 psig (27.6 bar)
- Tight shutoff with elastomer seats

Models

## Fisher pressure reducing models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

MR95

### Fisher MR95 Series pressure regulator

Compact, direct-operated and large-capacity, for steam, water, gases and process chemicals.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletin-mr95-series-industrial-pressure-regulators-bulletin-fisher.pdf) [Pressure reducing regulators](https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/) [View sheet](https://its-ve.com/en/products/final-control/regulators/mr95/)

Fisher

67C

### Fisher 67C Series instrument supply regulators

Regulator and filter regulator that supplies pneumatic and electro-pneumatic controllers.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-67c-series-instrument-supply-regulators-bulletin-fisher.pdf) [Pressure reducing regulators](https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2067C)

Fisher

67D

### Fisher 67D Series pressure reducing regulators

Delivers constant reduced pressure to pilot-operated controllers and other pneumatic instrumentation.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-67d-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Pressure reducing regulators](https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2067D)

Fisher

627

### Fisher 627 Series commercial / industrial regulators

Direct-operated, for low and high-pressure systems on natural gas, air and other gases.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-627-series-pressure-reducing-regulators-bulletin-fisher.pdf) [Pressure reducing regulators](https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20627)

Fisher

MR105

### Fisher Type MR105 direct-operated pressure reducing regulator

High capacity for liquid, air and gas: lube oil, cooling water and pump bypass.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletins-mr105-direct-operated-pressure-reducing-regulators-bulletin-fisher-en.pdf) [Pressure reducing regulators](https://its-ve.com/en/products/final-control/regulators/pressure-reducing-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR105)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The spring pushes the plug toward the open position; outlet pressure, under the diaphragm, pushes it toward closure. When demand grows, outlet pressure falls slightly, the spring wins and the regulator opens further. That small drop needed to open, called droop or proportional band, is the characteristic of every direct-operated regulator and defines its accuracy.

Controlled pressure reaches the diaphragm by internal registration, through the body itself, or by an external control line that takes pressure downstream, where flow is already stable. Selection starts from three values, inlet pressure, the outlet pressure to be controlled and the required flow, and is completed with body size, materials and the accuracy the service demands.

### Constructions and trim

- #### MR95 Series for process Compact, large-capacity body with internal or external registration, graphite gaskets, elastomer seats for tight shutoff and constructions for arctic and cryogenic temperatures.
- #### 67C and 67D Series for instruments Compact regulators and filter regulators, suitable for panel mounting, with internal relief and an optional stainless steel construction.
- #### 627 Series for gas Direct-operated with balanced trim and, depending on the type, an internal relief valve with operation indicator; performance varies with construction.
- #### Internal or external registration Internal registration simplifies installation; the external control line improves regulation when there is turbulence at the regulator outlet.

Applications

## Where they are used

- Superheated steam, steam injection and line tracing
- Nitrogen purging and pneumatic supply
- Boiler feed water, cooling water and process chemicals
- Fuel lines and natural gas, air and other gas lines at low and high pressure
- Air or gas supply to controllers, positioners and other instruments

### Why it is chosen

- No signal, air or external power: the regulator takes its energy from the fluid itself
- Fast response to demand changes, thanks to the direct action of the diaphragm on the plug
- MR95 with tight shutoff on elastomer seats and a large turndown ratio, according to the manufacturer
- Simple maintenance, with few parts and repair kits by model

### Worth weighing

- Outlet pressure falls somewhat as flow increases (droop): when more accuracy or more capacity is required, a pilot-operated regulator is the right choice
- A pressure reducing regulator does not protect against overpressure if it fails open; a relief, a monitor or a safety shutoff is needed downstream depending on the service

ITS de Venezuela

## What ITS does with pressure reducing regulators

ITS quotes new Fisher regulators and their genuine parts (diaphragms, springs, plugs, seats, orifices and gaskets), and services installed ones: disassembly, inspection, soft parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, plus field service on regulating racks, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: fluid, maximum and minimum inlet pressure, desired outlet pressure, maximum and minimum flow, temperature, connection size and type; or the model and serial number from the nameplate if it is a replacement.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR95%20regulator)
- ### Regulators and relief Maintenance of pressure regulators and relief devices.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.
- ### Inventory management Critical spares identified and available before the shutdown.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Regulators Pressure-reducing, backpressure, fuel gas and slam-shut.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What is regulator droop?
It is the fall in outlet pressure below set point as flow increases. In a direct-operated regulator the plug only opens further if the diaphragm moves, and for that the controlled pressure must drop a little. It is reduced by choosing the spring range and orifice size well, or by moving to a pilot-operated regulator when the service cannot tolerate it.

Internal registration or external control line?
Internal registration measures pressure inside the body itself and is enough for most services. The external control line takes pressure a few diameters downstream, where flow is more stable, and improves regulation at high flows or in piping with turbulence. The MR95 Series is offered in both configurations.

Regulators

## More regulators families

### Pilot-operated regulators for natural gas

A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

### Back pressure regulators and relief

They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

### Fuel gas valves

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

### Slam-shut devices

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

### Steam regulators

They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need pressure reducing regulators, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote pressure reducing regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20MR95%20regulator) [Regulators and relief](https://its-ve.com/en/services/regulators-and-relief/)