# Fisher 92B, 92S and 92C steam regulators and pressure reducing valves

> Fisher 92B, 92S, 92C and MR95 steam regulators: they reduce distribution pressure to point-of-use pressure, with no external power. Quotations.

Source: https://its-ve.com/en/products/final-control/regulators/steam-regulators/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- [Regulators](https://its-ve.com/en/products/final-control/regulators/)
- Steam regulators

[Regulators](https://its-ve.com/en/products/final-control/regulators/)

Regulators · Fisher

# Fisher steam pressure regulators

The reducing valve at every steam point of use: it takes its energy from the steam itself, follows equipment demand and holds heating pressure steady.

[Quote steam pressure regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092B%20steam%20regulator) [Regulators](https://its-ve.com/en/products/final-control/regulators/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a steam regulator?

A steam regulator lowers pressure from the distribution lines to the level required at each point of use, automatically and without external power, balancing the force of a spring against steam pressure.

On steam, pressure fixes the condensing temperature, so stability weighs more and most main reducing valves are pilot-operated. The Fisher 92B is the industry standard; the 92S serves high-cycle duty, the 92C is the cost-effective option and the MR95 covers superheated steam.

- Self-operated · no instrument air
- Wet and dry steam
- Direct-operated or pilot-operated
- 92S: set point up to 250 psig (17.2 bar) and 650 °F (343 °C)

Models

## Fisher models for steam

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

92B

### Fisher Type 92B pressure reducing valve

Main pressure reducing valve in process heating: heat exchangers, evaporators, digesters and reactors.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92b-pressure-reducing-valve-bulletin-fisher.pdf) [Steam regulators](https://its-ve.com/en/products/final-control/regulators/steam-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092B)

Fisher

92S

### Fisher Type 92S pilot-operated steam regulator

Piston actuated for high-cycle steam service, with lapped seating surfaces.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92s-pilot-operated-steam-regulator-bulletin-fisher-en.pdf) [Steam regulators](https://its-ve.com/en/products/final-control/regulators/steam-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092S)

Fisher

92C

### Fisher Type 92C self-powered control valve

Cost-effective steam reducing regulator, with a Type 6392 pilot or pressure-loaded for remote adjustment.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/data-sheets-92c-self-powered-control-valve-bulletin-fisher-en.pdf) [Steam regulators](https://its-ve.com/en/products/final-control/regulators/steam-regulators/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092C)

Fisher

MR95

### Fisher MR95 Series pressure regulator

Direct-operated for superheated steam, steam injection and tracing.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/bulletin-mr95-series-industrial-pressure-regulators-bulletin-fisher.pdf) [Steam regulators](https://its-ve.com/en/products/final-control/regulators/steam-regulators/) [View sheet](https://its-ve.com/en/products/final-control/regulators/mr95/)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

In the pilot-operated versions, a pilot senses outlet pressure and uses the inlet steam itself as the operating medium to position the main valve: no separate air supply is needed. As demand increases, outlet pressure falls, the pilot opens and loads the main valve actuator, which opens until set point is recovered.

Proper sizing considers inlet and outlet pressure, flow rate, temperature and steam quality, that is, the proportion of vapor to liquid. Emerson also recommends a bypass line for maintenance, isolation valves and steam traps that remove condensate and extend system life.

### Constructions and trim

- #### Type 92B Pilot-operated main reducing valve, with three pilots to choose from and no atmospheric bleed, easily modified for special service.
- #### Type 92S Piston actuated for high-cycle service. Valve and pilot with lapped seating surfaces to minimize leakage; 6492H and 6492L pilots with bellows-sealed stems. In steel and stainless steel.
- #### Type 92C With a Type 6392 pilot, which uses inlet pressure as the operating medium, or without a pilot as a pressure-loaded regulator when remote adjustment is required. In-line maintenance.
- #### MR95 Series Direct-operated and compact, for superheated steam, injection and tracing, where simplicity matters more than accuracy.

Applications

## Where they are used

- Reducing stations between the high-pressure header and the medium- and low-pressure networks
- Process heating: heat exchangers, evaporators, digesters and reactors
- Boiler outlets, separators, desuperheaters and deaerators
- Distribution lines, steam injection and tracing
- High-cycle services such as batch processes

### Why it is chosen

- No instrument air or signal: inlet steam drives the valve
- Accurate, stable control in dirty operating environments, according to the manufacturer for the 92B
- Lapped seats and bellows-sealed pilots on the 92S for high-cycle service
- Versions with remote set point adjustment by pressure loading

### Worth weighing

- Condensate and dirt are the usual cause of failure: the station needs a separator or trap upstream, a strainer and drains in good condition
- Downstream of every steam reducing valve there must be a safety valve sized for the regulator failing open

ITS de Venezuela

## What ITS does with steam regulators

ITS quotes new Fisher steam regulators, their pilots and their genuine parts (diaphragms, pistons, seats, plugs, springs and gaskets), and services installed reducing stations: disassembly, cleaning, seat lapping, parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, plus field service, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: inlet steam pressure and temperature, desired outlet pressure, maximum and minimum flow, whether steam is saturated or superheated, line size and connections; or the model and serial number from the nameplate.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092B%20steam%20regulator)
- ### Regulators and relief Maintenance of pressure regulators and relief devices.
- ### Inspection and diagnostics Valve condition assessment before deciding to repair or replace.
- ### Field service On-site support, shutdowns, commissioning and start-up.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Regulators Pressure-reducing, backpressure, fuel gas and slam-shut.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What data is needed to size a steam pressure reducing valve?
Inlet and outlet pressure, maximum and minimum flow, temperature and steam quality, that is, whether it is saturated, wet or superheated. With that data the valve and pilot type and size are chosen. An oversized regulator works almost closed, wears the seat and regulates poorly at low load.

Why does a steam reducing valve stop holding pressure?
The most frequent causes are dirt or scale in the pilot, a main seat eroded by wet steam, a damaged diaphragm or piston, and condensate reaching the valve because a trap is out of service. Repair includes cleaning or replacing the pilot, lapping or replacing the seats and checking the station drainage.

Regulators

## More regulators families

### Pressure reducing regulators

They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

### Pilot-operated regulators for natural gas

A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

### Back pressure regulators and relief

They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

### Fuel gas valves

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

### Slam-shut devices

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need steam pressure regulators, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote steam pressure regulators](https://its-ve.com/en/request-a-quote/?modelo=Fisher%2092B%20steam%20regulator) [Regulators and relief](https://its-ve.com/en/services/regulators-and-relief/)