# Fisher i2P-100, 846, 646 and 546 I/P transducers

> Fisher i2P-100, 846, 646 and 546 electro-pneumatic transducers: they convert the 4-20 mA signal into a proportional pressure for actuators and positioners.

Source: https://its-ve.com/en/products/final-control/valve-positioners/i-p-transducers/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- [Positioners and instruments](https://its-ve.com/en/products/final-control/valve-positioners/)
- I/P transducers

[Positioners and instruments](https://its-ve.com/en/products/final-control/valve-positioners/)

Positioners and instruments · Fisher

# Fisher electro-pneumatic (I/P) transducers

From current to pressure: the transducer translates the control system output into the language the pneumatic actuator and positioner understand.

[Quote electro-pneumatic transducers](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20i2P-100%20I%2FP%20transducer) [Positioners and instruments](https://its-ve.com/en/products/final-control/valve-positioners/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is an I/P transducer?

An electro-pneumatic transducer, or I/P (current-to-pressure), converts a 4-20 mA input into a proportional pressure output. It is the link that lets an electronic control loop drive an air-operated valve.

Its integral pneumatic relay gives it the capacity to drive control valve assemblies without additional boosters or positioners, and it operates stably into small volumes. A transducer that drifts or leaks degrades control without it being obvious.

- 4-20 mA input
- Proportional pneumatic output
- Integral pneumatic relay
- Natural gas version (i2P-100)

Models

## Fisher I/P transducer models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

i2P-100

### Fisher i2P-100 electro-pneumatic transducer

Suited to natural gas service, with good tolerance to dirty supply.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/fisher-i2p-100-electro-pneumatic-transducer-product-bulletin-d103197x012.pdf) [I/P transducers](https://its-ve.com/en/products/final-control/valve-positioners/i-p-transducers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20i2P-100)

Fisher

846

### Fisher 846 electro-pneumatic transducer

Rugged, field-mountable, with electronic feedback that corrects for supply variations.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102127x012.pdf) [I/P transducers](https://its-ve.com/en/products/final-control/valve-positioners/i-p-transducers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20846)

Fisher

646

### Fisher 646 electro-pneumatic transducer

Converts the 4-20 mA signal into a proportional 0.2 to 1.0 bar (3 to 15 psig) output.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101374x012.pdf) [I/P transducers](https://its-ve.com/en/products/final-control/valve-positioners/i-p-transducers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20646)

Fisher

546

### Fisher 546 electro-pneumatic transducers

Torque motor, nozzle-flapper and pneumatic relay to convert the signal.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103603x012.pdf) [I/P transducers](https://its-ve.com/en/products/final-control/valve-positioners/i-p-transducers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20546)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The converter module receives the DC current signal from the control device and uses it to operate coils in a force-balanced beam system, which controls bleed air through an integral nozzle and flapper arrangement. Nozzle pressure is the input signal to the relay, and relay output pressure is piped directly to the valve and actuator assembly.

The models differ in how they secure that conversion. The 846 adds electronic feedback that corrects for supply pressure variations and leakage. The i2P-100 separates its parts into dual compartments, with an explosive-fluid seal, and tolerates dirty supply well. The 546 uses a torque motor, a nozzle-flapper and a pneumatic relay.

### Constructions and trim

- #### Fisher 646 Converter module that turns the 4-20 mA signal into a proportional 0.2 to 1.0 bar (3 to 15 psig) output.
- #### Fisher 846 Rugged, field-mountable transducer with electronic feedback that corrects for supply variations and leakage.
- #### Fisher i2P-100 For natural gas service: dual compartments, an explosive-fluid seal and good tolerance to dirty supply.
- #### Fisher 546 Torque motor, nozzle-flapper and pneumatic relay to convert the DC signal into a proportional pneumatic output.

Applications

## Where they are used

- Control valves with pneumatic actuators driven by a 4-20 mA signal
- Sending the signal to a pneumatic positioner or another pneumatic instrument
- Installations that use natural gas as the supply medium
- Linking electronic loops to existing pneumatic final elements

### Why it is chosen

- Integral relay with the capacity to drive the actuator without an additional booster
- Stable, accurate output into small-volume chambers as well
- Electronic feedback on the 846 against supply variations and leakage
- Construction for natural gas and dirty supply on the i2P-100

### Worth weighing

- It converts the signal but does not measure valve position: if the service demands position accuracy, a positioner or a digital controller is needed
- The quality of the supply air or gas determines the stability of the conversion

ITS de Venezuela

## What ITS does with I/P transducers

We quote new Fisher transducers and genuine parts (converter and relay modules, gasket and O-ring kits, gauges and feedback parts), check and calibrate them on the bench in our Puerto Ordaz workshop and verify in the field that output pressure matches the signal. When the loop justifies it, we evaluate replacing the transducer and positioner set with a FIELDVUE digital valve controller. Parts are managed through the Venezuela ↔ Orlando inventory. For a quotation, send the model, the input signal, the output range, the supply medium and pressure and the area classification.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20i2P-100%20I%2FP%20transducer)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Control valve repair Repair to the manufacturer’s specification, with bench tests and report.
- ### FIELDVUE and instrumentation Configuration, diagnostics and commissioning of controllers and instruments.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Positioners and instruments Positioners, FIELDVUE digital controllers and valve instruments.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What does I/P mean?
It is shorthand for current-to-pressure: the transducer converts the 4-20 mA current signal sent by the control system into a proportional pneumatic pressure, which is the signal the pneumatic actuator or positioner understands.

Does an I/P transducer replace the positioner?
Not always. The transducer delivers a pressure proportional to the signal and its integral relay can drive the actuator directly, but it does not measure valve position. When friction or process forces prevent that pressure from becoming an exact position, a positioner is added or a digital valve controller is used.

Positioners and instruments

## More positioners and instruments families

### FIELDVUE digital valve controllers

The instrument that positions the valve and also diagnoses it: it evaluates the performance and health of the assembly without shutting down the process.

### Pneumatic positioners

They deliver air to the actuator until stem or shaft position matches the set point, with a pneumatic or 4-20 mA signal.

### Process controllers

They close the loop in the field: they measure the variable, compare it with the set point and send the corrective signal to the final element.

### Level controllers

They measure and control liquid level, the interface between two liquids or density with a displacer sensor, in pneumatic, electric or digital versions.

### Volume boosters and accessories

The accessories that complete the assembly: they speed up the stroke, report position, condition the air and define what the valve does if supply fails.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need electro-pneumatic transducers, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote electro-pneumatic transducers](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20i2P-100%20I%2FP%20transducer) [Calibration](https://its-ve.com/en/services/calibration/)