# Fisher valve positioners and FIELDVUE digital valve controllers

> Pneumatic positioners, FIELDVUE digital valve controllers (DVC7K, DVC6200), process and level controllers and Fisher I/P transducers. Retrofit and…

Source: https://its-ve.com/en/products/final-control/valve-positioners/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Final control](https://its-ve.com/en/products/final-control/)
- Positioners and instruments

[Final control](https://its-ve.com/en/products/final-control/)

Final control · Category

# Fisher positioners and instruments

From the pneumatic positioner to the FIELDVUE digital controller: the instruments that position the valve and watch its condition.

[Quote positioners](https://its-ve.com/en/request-a-quote/?modelo=FIELDVUE) [Diagnose my control valves](https://its-ve.com/en/services/fieldvue-and-instrumentation/)

## What does a positioner do?

A positioner compares the control signal with the actual stem or shaft position and adjusts the actuator air pressure until they match; this corrects for friction and hysteresis and improves the control valve’s accuracy.

A Fisher FIELDVUE digital valve controller is a microprocessor-based positioner: it receives 4-20 mA, HART, FOUNDATION fieldbus or PROFIBUS signals and measures travel, pressures and temperature to diagnose the assembly without removing it, using ValveLink software.

## How a valve positioner works

### Pneumatic valve positioners

In plants that keep a pneumatic signal (3-15 psi) as the set point, the positioner receives that signal from the controller and modulates the supply pressure to the actuator, so the stem or shaft position is proportional to the input signal.

Fisher models 3582, 3610J, 3660

### Analog I/P valve positioners

They receive a 4-20 mA signal and convert it, with a built-in I/P transducer, into a pneumatic signal; from there they work as a pneumatic positioner and drive the valve to a position proportional to the current.

Fisher models 3582i, 3620J, 3661

### Digital valve controllers

Microprocessor-based, they convert the 4-20 mA signal or digital communication (HART, FOUNDATION fieldbus, PROFIBUS) into actuator pressure and also measure travel, pressures and temperature to diagnose the valve in service with ValveLink software.

Fisher FIELDVUE models DVC7K, DVC6200, DVC2000

## Positioners and instruments

Modulate the valve and monitor the process variables.

Instrumentation enables valves, actuators and regulators to work more efficiently in many different applications. It serves five purposes: improving process control, enhancing safety, measuring responsiveness, diagnosing issues and boosting performance or speed of response. Fisher digital, pneumatic and electronic instruments govern valve position and variables such as pressure, temperature or level.

### What’s your challenge?

Every valve is installed in a different application and, without diagnostics, the state of the assembly is only known by taking it apart.

### What’s your opportunity?

With the right instrument, the valve follows the set point accurately and, if it is digital, reports its friction, dead band and leaks before the failure.

### FIELDVUE digital valve controllers

**FIELDVUE digital valve controllers.** The instrument that positions the valve and also diagnoses it: it evaluates the performance and health of the assembly without shutting down the process.

- DVC7K
- DVC6200
- DVC6200 SIS
- DVC2000

### Pneumatic positioners

**Pneumatic positioners.** They deliver air to the actuator until stem or shaft position matches the set point, with a pneumatic or 4-20 mA signal.

- 3582
- 3582i
- 3570
- 3610J / 3620J
- 3660 / 3661
- 3710 / 3720

### Process controllers

**Process controllers.** They close the loop in the field: they measure the variable, compare it with the set point and send the corrective signal to the final element.

- DPC2K
- C1
- 4195K
- 4194
- 4196

### Level controllers

**Level controllers.** They measure and control liquid level, the interface between two liquids or density with a displacer sensor, in pneumatic, electric or digital versions.

- L2t
- L2
- L2e
- DLC3100
- 2500
- 249

### I/P transducers

**I/P transducers.** They convert the 4-20 mA electrical signal into a proportional pneumatic pressure: the link between the electronic loop and the air-operated valve.

- i2P-100
- 846
- 646
- 546

### Volume boosters and accessories

**Volume boosters and accessories.** The accessories that complete the assembly: they speed up the stroke, report position, condition the air and define what the valve does if supply fails.

- 2625
- VBL
- 4400
- 377
- 67CFR

Fisher models

## Positioners and instruments by model

Each model with its official technical bulletin, which you can read right here, and a quote one click away.

Find a model
- Pneumatic valve positioner ### Fisher 3570 Pneumatic positioner that brings the valve stem to a position proportional to the controller signal. It is normally used with piston actuators, and the family also works with long-stroke cylinders and diaphragms. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203570)
- Pneumatic valve positioner ### Fisher 3570C Pneumatic positioner from the 3570 family that brings the valve stem to a position proportional to the controller signal. It is normally used with pneumatic piston actuators. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203570C)
- Pneumatic valve positioner ### Fisher 3570P Pneumatic positioner from the 3570 family that brings the valve stem to a position proportional to the controller signal. It is normally used with pneumatic piston actuators. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203570P)
- Pneumatic valve positioner ### Fisher 3570PC Pneumatic positioner from the 3570 family that brings the valve stem to a position proportional to the controller signal. It is normally used with pneumatic piston actuators. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104021x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203570PC)
- Single-acting pneumatic positioner ### Fisher 3582 Pneumatic positioner for diaphragm-actuated sliding-stem control valves. It modulates supply pressure to the actuator so the stem position is proportional to the pneumatic input signal. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200062x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203582)
- Single-acting pneumatic positioner ### Fisher 3660 Rugged single-acting pneumatic positioner for actuators on sliding-stem valves in throttling duty. It gives a position proportional to the controller's pneumatic signal, with fast response and vibration tolerance. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101402x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203660)
- Rotary pneumatic positioner ### Fisher 3710 Pneumatic positioner for diaphragm or piston rotary actuators, bringing the ball or disk to the position called for by the input signal. It can be set up as single- or double-acting and uses spool valve technology. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200437x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203710)
- Electro-pneumatic converter for positioner ### Fisher 3722 Electro-pneumatic converter that goes with the 3710 and 3720 positioners, designed for diaphragm or piston rotary actuators. It lets the valve respond to a direct-current input signal. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200437x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%203722)
- Digital valve controller ### Fisher FIELDVUE DVC7K Digital valve controller with flexible connectivity, an easy interface and real-time analysis of valve performance. Its linkage-less feedback has no physical contact, so parts do not wear. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fieldvue-dvc7k-h-digital-valve-controller-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC7K)
- Digital valve controller ### Fisher FIELDVUE DVC2000 Simple digital valve controller that helps a plant run closer to setpoint. Its linkage-less feedback is easy to install, and a local interface lets you configure, calibrate and tune the instrument. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103167x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC2000)
- Digital valve controller ### Fisher FIELDVUE DVC6200 Digital valve controller that lets a plant run closer to setpoint and improve product quality. FIELDVUE diagnostics watch the valve online, using linkage-less, non-contact feedback. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103415x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC6200)
- Digital valve controller for SIS ### Fisher FIELDVUE DVC6200 SIS Digital controller for safety instrumented system valves. It handles the safety shutdown function and extends the time between proof tests through partial stroke testing, while monitoring the health of the whole valve assembly. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103555x012-bulletin-fieldvue-dvc6200-sis-digital-valve-controller-for-safety-instrumented-systems-sis-fisher.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC6200%20SIS)
- Digital valve controller ### Fisher FIELDVUE DVC6200f The DVC6200f digital valve controller helps a plant run closer to setpoint. FIELDVUE diagnostics monitor the valve around the clock to assess performance and reliability, with non-contact feedback. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103422x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC6200f)
- PROFIBUS PA digital valve controller ### Fisher FIELDVUE DVC6200p Digital valve controller with PROFIBUS PA communication and non-contact travel feedback. Besides converting the digital signal into pneumatic pressure, it reports on the condition of the instrument, actuator and valve. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103564x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DVC6200p)
- Local control panel ### Fisher LCP100 Local control panel used together with the FIELDVUE DVC6200 SIS digital valve controller to manually open, close or test a safety shutdown valve in the field. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/fisher-lcp100-local-control-panel-bulletin-d103604x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20LCP100)
- Electro-pneumatic I/P transducer ### Fisher 546 The 546, 546S and 546NS transducers turn a direct-current signal into a proportional pneumatic output using a torque motor, nozzle-flapper and relay. The design resists vibration and meets typical seismic requirements for nuclear service. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103603x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20546)
- Electro-pneumatic I/P transducer ### Fisher 546NS The 546NS transducer turns a direct-current signal into a proportional pneumatic output using a torque motor, nozzle-flapper and relay. The design resists vibration and meets typical seismic requirements for nuclear service. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20546NS)
- Electro-pneumatic I/P transducer ### Fisher 646 Transducer that converts a 4 to 20 mA input into a proportional 0.2 to 1.0 bar (3 to 15 psig) pneumatic output. Its balanced converter module lowers vibration sensitivity, and its compact size eases mounting. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d101374x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20646)
- Electro-pneumatic I/P transducer ### Fisher 846 Transducer that converts a controller's electrical signal into the pneumatic signal that operates a valve actuator or positioner. Electronic feedback corrects for supply pressure variations and downstream leakage. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d102127x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20846)
- Electro-pneumatic I/P transducer ### Fisher i2P-100 I/P transducer with dual compartments and an explosive-fluid seal that keeps natural gas out of the electrical conduit. It resists corrosion, dirty supply and vibration, and is approved for natural gas as the pneumatic supply. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/fisher-i2p-100-electro-pneumatic-transducer-product-bulletin-d103197x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20i2P-100)
- Pressure indicating controller ### Fisher 4190 Pneumatic indicating controller that shows process pressure and set point on an easy-to-read scale. Its simple design eases maintenance and reduces spare parts inventory, and it is used where accurate pressure monitoring is required. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200154x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204190)
- Differential pressure indicating controller ### Fisher 4194 Controller that senses two pressures, compares the difference with a set point and shows it on a process scale. Supports proportional, reset or differential gap control, with options such as an auto/manual station. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200048x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204194)
- Differential pressure indicating controller ### Fisher 4194A Controller that senses two pressures, compares the difference with a set point and shows it on a process scale. Supports proportional, reset or differential gap control, with options such as an auto/manual station. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200048x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204194A)
- Differential pressure indicating controller ### Fisher 4194B Controller that senses two pressures, compares the difference with a set point and shows it on a process scale. Supports proportional, reset or differential gap control, with options such as an auto/manual station. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200048x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204194B)
- Differential pressure indicating controller ### Fisher 4194C Controller that senses two pressures, compares the difference with a set point and shows it on a process scale. Supports proportional, reset or differential gap control, with options such as an auto/manual station. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200048x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204194C)
- Gauge pressure indicating controller ### Fisher 4195K Controller that shows process pressure and set point on a readable scale and sends a pneumatic signal to the control element. Versions are available for proportional, proportional-plus-reset and differential gap on/off control. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200050x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204195K)
- Temperature indicating controller ### Fisher 4196 Controller that displays process temperature and set point on an easy-to-read scale. Used where accurate temperature monitoring and control are needed, with a simple design that is easy to maintain and needs few spare parts. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200054x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204196)
- Pneumatic high-low pressure pilot ### Fisher 4660 Pneumatic pilot that activates safety shutdown systems on flowlines, production vessels and compressors. It offers one or two set points and switches from full to zero output pressure when the process leaves the range. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200051x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204660)
- Zero-bleed pilot controller ### Fisher 4680 Fully mechanical instrument for pressure regulation with sliding-stem or rotary control valves in midstream and downstream natural gas. In steady state it releases no gas to the atmosphere. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/documents/fisher-4680-pilot-controller-en-us-11947596.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%204680)
- Pneumatic pressure controller and transmitter ### Fisher C1 Durable, dependable pneumatic pressure controller and transmitter that also addresses air and gas consumption. It can use a Bourdon tube for high pressures or bellows for vacuum and low pressures. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/pressure-management/documents/product-bulletin-fisher-c1-pneumatic-controllers-and-transmitters.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20C1)
- Digital position transmitter ### Fisher FIELDVUE 4400 Transmitter that senses the position of rotary or sliding-stem valves, vents and dampers with non-contact feedback. It gives 4-20 mA position output, is SIL 2 capable and has two solid-state NAMUR limit switches. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fisher-fieldvue-4400-digital-position-transmitter-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%204400)
- Digital process controller ### Fisher FIELDVUE DPC2K Electro-pneumatic PID controller that can replace pneumatic controllers in a single continuous loop. It offers application flexibility, simple configuration and high-speed network communication for expansions or modernization projects. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fisher-fieldvue-dpc2k-digital-process-controller-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DPC2K)
- Caged level sensor ### Fisher 249 Caged level sensor that measures changes in liquid level, interface level or density using the Archimedes principle. It runs more steadily than a cageless sensor in vessels with internal obstructions or turbulence. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200039x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20249)
- Liquid level switch ### Fisher 2100 On/off switches, pneumatic 2100 and electric 2100E, that sense high or low level with a displacer in an external cage. They typically operate safety shutdown systems in oil and gas production. [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%202100)
- Pneumatic level controller ### Fisher 2500 Rugged, simply built pneumatic controller for liquid level, interface level and density service. Set point, proportional valve opening and reset are changed with simple dial knobs. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200037x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%202500)
- Pneumatic level controller ### Fisher 2506 Rugged, simply built pneumatic controller from the 2500 family for liquid level, interface level and density service. Set point, proportional valve opening and reset are adjusted with dial knobs. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200044x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%202506)
- Pneumatic level controller ### Fisher 2516F 2500 series pneumatic controller for liquid level, interface level and density service, simple and rugged in construction. Set point, proportional band and reset are changed with dial knobs. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200044x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%202516F)
- FOUNDATION fieldbus digital level controller ### Fisher FIELDVUE DLC3020f FOUNDATION fieldbus instrument that measures liquid or interface level using displacement sensing. Besides reporting the process variable, it can act as a PID controller or a level switch. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103433x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DLC3020f)
- Digital level controller ### Fisher FIELDVUE DLC3100 HART communicating instrument that measures liquid level, interface level or density using displacement sensing. Its local interface with four push buttons and an LCD allows setup without external tools. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104216x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DLC3100)
- Digital level controller for safety systems ### Fisher FIELDVUE DLC3100 SIS HART instrument that measures liquid or interface level with a displacement sensor, with safety integrity level capability. It integrates into new or existing safety systems and provides field diagnostics. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104216x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20DLC3100%20SIS)
- Electric liquid level controller ### Fisher FIELDVUE L2t L2 series level controller with a displacer sensor that detects liquid level or the interface between two liquids of different specific gravity. Applied on gas separators and scrubbers, with zero emissions. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fisher-fieldvue-l2t-electric-level-controller-en.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20FIELDVUE%20L2t)
- Pneumatic liquid level controller ### Fisher L2 y L2sj Level controllers with a displacer sensor that detect liquid level or the interface between two liquids. Well suited to high-pressure level control in natural gas production, compression and processing. [View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103034x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2%20y%20L2sj)
- Electric on/off level controller ### Fisher L2e Electric on/off controller with a force-balanced displacer sensor for liquid level or liquid interface. Used on separators, treaters and scrubbers in the oil and gas industry. [View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103531x012.pdf) [Quote](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2e)

Manufacturer photos and technical bulletins. Fisher and FIELDVUE are marks of Emerson.

Models

## Product pages

Description, features and a link to the manufacturer’s official documentation.

Fisher

DVC7K

### Digital valve controller

High-performance digital valve controller with embedded prognostics and Advice at the Device™ technology, processing and analyzing data locally to deliver actionable information in real time.

Check availability

Fisher

L2t

### Liquid level controller

Rugged liquid level controller that uses a displacer-type sensor to detect level or the interface between two liquids of different densities.

Check availability

Fisher

DPC2K

### Digital process controller

Electro-pneumatic digital process controller with PID control, designed to replace pneumatic controllers on continuous single loops.

Check availability

Models

## The FIELDVUE family

What each model does and which variable it governs.

| Model | Type | Variable | Main trait |
| --- | --- | --- | --- |
| DVC7K | Digital valve controller | Position | On-board analytics and prognostics; Bluetooth® for the local interface |
| DVC6200 | Digital valve controller | Position | Current generation alongside the DVC7K |
| DVC2000 | Digital valve controller | Position | Previous generation |
| DPC2K | Digital process controller | Pressure, flow, level, temperature | Closed-loop PID; replaces pneumatic controllers |
| L2t | Liquid level controller | Level and interface | Displacer sensor; drives an electric valve |

Source: descriptions published by ITS from the manufacturer’s documentation. See the official data sheet on each product page.

Retrofit

## Replacing analog positioners

A digital controller can replace the analog positioner on most pneumatic actuators. The change requires the right mounting kit for the actuator, instrument configuration and travel calibration.

We assess mounting and configuration as part of the equipment re-engineering and upgrade service, and train the staff who will run the diagnostics.

[Automation and control](https://its-ve.com/en/services/automation-and-control/)

Brands

## Brands in this category

- [Fisher Control valves, FIELDVUE, regulators, OEM parts](https://its-ve.com/en/brands/fisher/)

**Other brands we supply.** We also quote ASCO solenoid valves to complete valve automation.

Service

## Services for this equipment

What we do on this equipment in the shop and in the field.

- ### FIELDVUE and instrumentation Configuration, diagnostics and commissioning of controllers and instruments.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.
- ### Technical training Courses on control valves, FIELDVUE and instrumentation.

Further reading

## Related articles and courses

- Article · Diagnostics [FIELDVUE Online Diagnostics: Seeing the Failure Before It Happens](https://its-ve.com/en/blog/fieldvue-online-diagnostics-before-failure/)
- Article · Diagnostics [Fisher ValveLink Pro: diagnosing the DVC7K without being a specialist](https://its-ve.com/en/blog/fisher-valvelink-pro-dvc7k-diagnostics/)
- Article · Training [FIELDVUE Course: What Your Team Masters in One Day on DVC Digital Controllers](https://its-ve.com/en/blog/fieldvue-dvc-one-day-course/)
- Course [1751 · FIELDVUE Fundamentals, Digital Instruments and Communicators](https://its-ve.com/en/services/training/1751-fieldvue-fundamentals/)
- Course [ValveLink and FIELDVUE Diagnostics — Operation](https://its-ve.com/en/services/training/valvelink-operation/)
- Course [ValveLink and FIELDVUE Diagnostics — Data Interpretation](https://its-ve.com/en/services/training/valvelink-data-interpretation/)

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
What is FIELDVUE?
It is Fisher’s family of digital valve controllers: it converts the control signal into pneumatic output to the actuator and diagnoses the assembly (position, pressures, friction) without removing it. Current models: DVC6200 and DVC7K; diagnostics are interpreted with ValveLink.

DVC6200 or DVC7K: what changes?
Both are current-generation digital controllers. The DVC7K adds on-board analytics and prognostics (Advice at the Device™) and Bluetooth® connectivity for the local interface. The choice depends on your system protocol, the diagnostic level you need and your plant standards; we confirm it from the nameplate data.

Can a digital controller replace an analog positioner?
On most pneumatic actuators, yes. It requires the right mounting kit for the actuator, instrument configuration and travel calibration.

What diagnostics does a FIELDVUE provide?
With ValveLink software you can identify friction, dead band, actuator leaks and instrument air problems, among others. This lets you schedule maintenance by valve condition rather than by calendar.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Want to diagnose your valves or change a positioner?

Give us the actuator model, your system protocol and the number of valves.

[Quote positioners](https://its-ve.com/en/request-a-quote/?modelo=FIELDVUE) [Diagnose my valves](https://its-ve.com/en/services/fieldvue-and-instrumentation/)