# Fisher level controllers

A submerged displacer turns level into a force, and the instrument converts it into the signal that moves the dump valve or reports to the control system.

[Quote level controllers](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2%20level%20controller) [Positioners and instruments](https://its-ve.com/en/products/final-control/valve-positioners/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a level controller?

A level controller is an instrument that uses analog, digital or pneumatic signals to measure, sense or control liquid level, the interface between two liquids or specific gravity (density) within a vessel.

The most widely used principle is the displacer: as the liquid rises, the buoyant force on the suspended cylinder increases and the instrument converts that change in force into a level signal. It allows throttling, on/off and gap control; a float offers only snap-acting or gap control.

- Level, interface and density
- Displacer sensor
- Pneumatic, analog or digital output
- Throttling, on/off or gap control

Models

## Fisher level control models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

L2t

### FIELDVUE L2t liquid level controller

Displacer sensor, throttling or on/off control and zero-emission operation with electric actuation.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fisher-fieldvue-l2t-electric-level-controller-en.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [View sheet](https://its-ve.com/en/products/final-control/valve-positioners/l2t/)

Fisher

L2

### Fisher L2 liquid level controller

Pneumatic, with a displacer sensor for level or interface in high-pressure service.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/product-bulletin-fisher-fieldvue-l2t-electric-level-controller-en.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2)

Fisher

L2e

### Fisher L2e electric level controller

Electric on/off controller for oil and gas separators, treaters and scrubbers.

[View manual](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d103531x012.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2e)

Fisher

DLC3100

### FIELDVUE DLC3100 digital level controller

Digital, for liquid level, interface or density together with a 249 sensor.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d104216x012.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20DLC3100)

Fisher

2500

### Fisher 2500 level controller and transmitter

Pneumatic proportional instrument, in combination with a 249 displacer sensor.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200037x012.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%202500)

Fisher

249

### Fisher 249 displacer sensors

Caged or cageless sensors to meet the mounting requirements of the vessel.

[View bulletin](https://www.emerson.com/is/content/emerson/en/final-control/flow-controls/documents/d200039x012.pdf) [Level controllers](https://its-ve.com/en/products/final-control/valve-positioners/level-controllers/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20249)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The displacer does not follow the surface like a float: it stays suspended and what varies is the buoyant force the liquid exerts on it. In interface service, that force changes with the position of the boundary between two liquids of different specific gravities. The instrument converts the change in force into its output, which throttles a dump valve, switches equipment or feeds the control system.

The output mode sets the models apart. The L2 is pneumatic and can run on natural gas, because its exhaust can be piped away; the L2e is electric and, together with a Fisher easy-Drive actuator, forms a fully electric level control loop; the L2t adapts to throttling or on/off control and arrives factory calibrated. The digital instruments and the 2500 are combined with a 249 sensor to meet mounting requirements.

### Constructions and trim

- #### L2 series (L2, L2e and L2t) Controllers with a displacer sensor for level or interface on separators and scrubbers: pneumatic, electric and FIELDVUE. The displacer is field-adjustable for vertical or horizontal operation.
- #### FIELDVUE digital level controllers Microprocessor-based, communicating instruments that, with a 249 sensor, measure liquid level, interface level or density.
- #### Fisher 2500 and 249 sensors Proportional-mode pneumatic controller and transmitter: it receives the change in level or interface from the buoyant force on the sensor displacer.
- #### Level switches They sense high or low level and operate, electrically or pneumatically, the safety shutdown systems of field equipment.

Applications

## Where they are used

- Separators, treaters and scrubbers in natural gas production, compression and processing
- Interface control between two liquids of different specific gravities
- Process vessels with throttling level control
- Fully electric level loops, with no instrument gas, using the L2e or L2t
- High or low level alarms and shutdowns on field equipment

### Why it is chosen

- One measurement principle serves level, interface or density
- Pneumatic, electric and digital versions on the same type of sensor
- Throttling control with the L2t reduces equipment wear by avoiding the full-stroke cycling of discrete control
- Zero-emission operation when combined with electric actuation

### Worth weighing

- The displacer is sized for the specific gravity of the fluids: a change of fluid means reviewing sizing and calibration
- Deposits on the displacer and the condition of the suspension mechanism affect accuracy and require inspection

ITS de Venezuela

## What ITS does with level controllers

We quote new Fisher level controllers and genuine parts (displacers, 249 sensor parts, torque tube assemblies, relays, gaskets and repair kits), repair and calibrate them in our Puerto Ordaz workshop and adjust them in the field on the vessel. We configure FIELDVUE instruments and evaluate the conversion of pneumatic loops to electric. Parts are managed through the Venezuela ↔ Orlando inventory. For a quotation, send the vessel type and its connection, the fluids and their specific gravities, the operating pressure and temperature, the required output and the nameplate model if it is a replacement.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2%20level%20controller)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### FIELDVUE and instrumentation Configuration, diagnostics and commissioning of controllers and instruments.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Positioners and instruments Positioners, FIELDVUE digital controllers and valve instruments.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Fisher catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
Displacer or float?
A float rises and falls with the liquid surface and offers only snap-acting (on/off) or gap control. A displacer is a cylinder that stays suspended in the liquid: what changes is the buoyant force, and that also allows throttling control, with a digital, analog or pneumatic signal.

Can the interface between two liquids be controlled?
Yes. Displacer sensors detect liquid level or the interface of two liquids of different specific gravities, because the buoyant force changes with the position of the boundary between them. The displacer is sized according to the specific gravities of both fluids.

Positioners and instruments

## More positioners and instruments families

### FIELDVUE digital valve controllers

The instrument that positions the valve and also diagnoses it: it evaluates the performance and health of the assembly without shutting down the process.

### Pneumatic positioners

They deliver air to the actuator until stem or shaft position matches the set point, with a pneumatic or 4-20 mA signal.

### Process controllers

They close the loop in the field: they measure the variable, compare it with the set point and send the corrective signal to the final element.

### I/P transducers

They convert the 4-20 mA electrical signal into a proportional pneumatic pressure: the link between the electronic loop and the air-operated valve.

### Volume boosters and accessories

The accessories that complete the assembly: they speed up the stroke, report position, condition the air and define what the valve does if supply fails.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need level controllers, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote level controllers](https://its-ve.com/en/request-a-quote/?modelo=Fisher%20L2%20level%20controller) [Calibration](https://its-ve.com/en/services/calibration/)