# Micro Motion Coriolis flow meters: ELITE, F-Series, R-Series and H-Series

> Micro Motion Coriolis meters: mass flow, density and temperature for liquids, gases and slurries. ELITE, F, R, H and T series. Quotation and calibration.

Source: https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Measurement](https://its-ve.com/en/products/measurement/)
- [Flow](https://its-ve.com/en/products/measurement/flow/)
- Coriolis flow meters

[Flow](https://its-ve.com/en/products/measurement/flow/)

Flow · Micro Motion

# Micro Motion Coriolis flow meters

The meter that measures mass, not volume: the reference when the balance, the batch or the custody transfer depends on the number.

[Quote coriolis flow meters](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20Coriolis%20flow%20meter) [Flow](https://its-ve.com/en/products/measurement/flow/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a Coriolis flow meter?

A Coriolis meter measures mass flow directly, with no pressure or temperature compensation. The same sensor delivers density and temperature; with them, the transmitter calculates volume flow and, in two-component mixtures, concentration.

The fluid passes through one or two vibrating tubes and slightly twists that vibration: the phase shift between inlet and outlet is proportional to mass. Micro Motion families vary in performance, materials, tube geometry and line size.

- Direct mass flow
- Density and temperature from the same device
- Liquids, gases and slurries
- Independent of flow profile

Models

## Micro Motion Coriolis meter families

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

ELITE

### Micro Motion ELITE Coriolis meter

The highest-performing family of the brand: custody transfer, critical control, LNG and two-phase flow.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20ELITE)

Fisher

F-Series

### Micro Motion F-Series Coriolis meter

Compact and drainable; the usual choice for process control in tight spaces.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20F-Series)

Fisher

R-Series

### Micro Motion R-Series Coriolis meter

General purpose: repeatable flow and density with a small footprint and low maintenance.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20R-Series)

Fisher

H-Series

### Micro Motion H-Series hygienic Coriolis meter

Hygienic, drainable and cleanable for food, beverage and life sciences.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20H-Series)

Fisher

T-Series

### Micro Motion T-Series straight-tube Coriolis meter

A single straight tube with titanium wetted parts: self-draining and plug-resistant.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20T-Series)

Fisher

5700

### Micro Motion 5700 field-mount transmitter

Transmitter for Coriolis sensors with a data historian and zero verification.

[Coriolis flow meters](https://its-ve.com/en/products/measurement/flow/coriolis-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%205700)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

A drive coil vibrates the tubes at their natural frequency and two pickoffs, one on each side, register the motion. With no flow, both signals are in phase. With flow, the inertia of the fluid delays one side relative to the other: that phase shift is the mass flow. Because the natural frequency drops as the fluid gets denser, the same signal yields density.

The assembly consists of a sensor, installed in the line, and a transmitter, integral or remote, that processes the signal and delivers it to the control system. The choice of transmitter defines the diagnostics, communication protocols and approvals available for each installation.

### Constructions and trim

- #### High-performance curved tubes (ELITE) The family for the most demanding services: custody transfer, critical control, LNG and two-phase flow. Available in 316L and 304L stainless steel and nickel alloy C22.
- #### Compact and drainable (F-Series and R-Series) Smaller sensors for process control and general-purpose duty, where footprint and installed cost matter more than maximum performance.
- #### Hygienic (H-Series) and straight tube (T-Series) The H-Series is compact, drainable and cleanable for sanitary processes. The T-Series uses a single straight titanium tube, self-draining and with an unobstructed flow path.
- #### Transmitters From the field-mount 5700, with a data historian and zero verification, to compact, two-wire or control-room versions, depending on the installation.

Applications

## Where they are used

- Custody transfer and fiscal metering of liquid hydrocarbons and gases
- Dosing, blending and batch loading, where the recipe is defined by mass
- Reactor feeds and process control with rapidly changing flow
- In-line density and concentration measurement together with flow
- Chemical injection, high-pressure services and cryogenic fluids with the dedicated families

### Why it is chosen

- Measures mass directly: no compensation for pressure, temperature or flow profile
- Three variables from a single measurement point: mass flow, density and temperature
- No moving parts in contact with the fluid
- One principle for liquids, gases and slurries

### Worth weighing

- Higher initial cost than other technologies; for very large pipes or cost-sensitive services another measuring principle may be the better fit
- Entrained gas and two-phase flow call for a careful choice of family: not every sensor tolerates them equally

ITS de Venezuela

## What ITS does with Coriolis meters

We quote new Micro Motion sensors and transmitters and their accessories, configure and commission the meter in the field, calibrate it through our calibration service, in the field and in the laboratory, and integrate it into the control loop. We reply with availability in Venezuela or Orlando. To quote, send the fluid, flow range, operating pressure and temperature, line size and connection, required accuracy and output signal, or the nameplate model if it is a replacement.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20Coriolis%20flow%20meter)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Flow Coriolis, magnetic, vortex and differential pressure.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Micro Motion catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
Does a Coriolis meter measure mass or volume?
It measures mass directly. The transmitter calculates volume flow by dividing mass flow by density, which the same sensor measures.

When is another technology a better fit than Coriolis?
The manufacturer says it plainly: for very large pipes or cost-sensitive applications, another technology may fit better. A magnetic meter handles conductive liquids in large diameters, and differential pressure or vortex cover steam and gases in general services.

Flow

## More flow families

### Magnetic flow meters

Volume flow in conductive liquids and slurries, with a full bore and no moving parts.

### Vortex flow meters

One meter for liquids, gases and steam, with no moving parts and no impulse lines.

### Differential pressure flow

Annubar, compact and integral orifice, and orifice plates: standardized measurement for gas, liquid and steam.

### Density and viscosity

Density, concentration, specific gravity and viscosity measured in line, in real time.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need coriolis flow meters, or calibration for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote coriolis flow meters](https://its-ve.com/en/request-a-quote/?modelo=Micro%20Motion%20Coriolis%20flow%20meter) [Calibration](https://its-ve.com/en/services/calibration/)
