# Rosemount differential pressure flow: Annubar and orifice plate

> Rosemount differential pressure flow meters: 3051SFA Annubar, 3051SFC compact orifice, 3051SFP integral orifice, and 1495 and 1595 plates. Quotation.

Source: https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Measurement](https://its-ve.com/en/products/measurement/)
- [Flow](https://its-ve.com/en/products/measurement/flow/)
- Differential pressure flow

[Flow](https://its-ve.com/en/products/measurement/flow/)

Flow · Rosemount

# Rosemount differential pressure flow meters

The most widespread measuring principle in industry, now in integrated assemblies that remove impulse lines and shorten straight runs.

[Quote differential pressure flow meters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFA%20Annubar%20flow%20meter) [Flow](https://its-ve.com/en/products/measurement/flow/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a differential pressure flow meter?

A differential pressure flow meter derives flow from the pressure drop created by a restriction in the line. It is the reference when the measurement must follow a standard, in large diameters and in steam, gas or liquid at high pressure or temperature.

The primary element creates the drop, which Bernoulli’s equation translates into flow, and a differential transmitter measures it. Rosemount offers stand-alone orifice plates and Annubar, or integrated, tested meters with no impulse lines.

- Gas, liquid and steam
- Primary element plus transmitter
- Annubar: low permanent loss
- Conditioning orifice: 2 straight diameters

Models

## Rosemount differential pressure flow models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

3051SFA

### Rosemount 3051SFA Annubar flow meter

Annubar averaging pitot tube with a 3051S transmitter: low pressure loss in large lines.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFA)

Fisher

3051SFC

### Rosemount 3051SFC compact orifice flow meter

Four-hole conditioning plate installed between existing flanges.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFC)

Fisher

3051SFP

### Rosemount 3051SFP integral orifice flow meter

For small line sizes, up to 1-1/2 in (40 mm) per the manufacturer.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFP)

Fisher

485

### Rosemount 485 Annubar primary element

Annubar primary element to pair with a differential pressure transmitter.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20485)

Fisher

1595

### Rosemount 1595 conditioning orifice plate

Four-hole design: only two diameters of straight run upstream and downstream.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201595)

Fisher

1495

### Rosemount 1495 orifice plate

Square-edged concentric plate compliant with ISO 5167, ASME MFC-3M and AGA 3.

[Differential pressure flow](https://its-ve.com/en/products/measurement/flow/differential-pressure-flow/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201495)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The orifice plate throttles the flow and pressure drops between the upstream and downstream taps. The Annubar is an averaging pitot tube that only partially obstructs the pipe: it senses impact pressure at the front, through sensing slots, and low pressure at the back. In both cases the transmitter calculates flow from the difference.

A multivariable transmitter also measures static pressure and temperature and delivers fully compensated mass flow from the same device. Integrated assemblies support several communication protocols, including a wireless option.

### Constructions and trim

- #### Annubar (3051SFA, 485 and 585 elements) Averaging pitot tube for gas, liquid and steam. Suited to large lines and wherever permanent pressure loss matters. The 585 handles severe service.
- #### Compact conditioning orifice (3051SFC, 405, 1595) Four-hole plate that needs only two diameters of straight run upstream and downstream. The 3051SFC mounts between flanges, with an integrated manifold.
- #### Integral orifice (3051SFP, 1195) Precision meter run with the plate built in, for small lines where a conventional plate loses accuracy.
- #### Standard orifice plate (1495) Square-edged concentric plate, paddle or universal type, for installations that must comply with ISO 5167, ASME MFC-3M or AGA 3.

Applications

## Where they are used

- Steam, gas and process liquids in refining, chemical and power
- Large-diameter lines, where the Annubar reduces permanent loss and installation cost
- Natural gas measurement per AGA 3
- Installations with little straight run available, using a conditioning plate
- Small injection and dosing lines with an integral orifice

### Why it is chosen

- A standardized principle familiar to every instrument technician
- Covers gas, liquid and steam at high pressure and temperature
- Integrated assemblies remove impulse lines and arrive leak-tested
- The transmitter is calibrated and replaced without disturbing the primary element

### Worth weighing

- Flow depends on the square root of differential pressure: the usable range is narrower than with other technologies
- On installations with impulse lines, plugging, leaks and signal instability are the usual failures

ITS de Venezuela

## What ITS does with differential pressure flow

We quote new Rosemount integrated flow meters, primary elements, transmitters and manifolds, configure and commission the assembly in the field, calibrate the differential pressure transmitter through our calibration service, in the field and in the laboratory, and integrate the measurement into the control loop. We reply with availability in Venezuela or Orlando. To quote, send the fluid, flow range, operating pressure and temperature, pipe diameter and schedule, available straight run and output signal.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFA%20Annubar%20flow%20meter)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Flow Coriolis, magnetic, vortex and differential pressure.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Rosemount catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
Annubar or orifice plate?
The Annubar is an averaging pitot tube that barely obstructs the line: it suits large diameters and services where permanent pressure loss costs energy. The orifice plate is the standardized element; in its four-hole conditioning version it needs only two diameters of straight run.

Which standards do Rosemount orifice plates meet?
According to the manufacturer, Rosemount 1495 single-hole orifice plates comply with ISO 5167, ASME MFC-3M and AGA Report No. 3.

Flow

## More flow families

### Coriolis flow meters

Direct mass flow, with density and temperature from the same device, for liquids, gases and slurries.

### Magnetic flow meters

Volume flow in conductive liquids and slurries, with a full bore and no moving parts.

### Vortex flow meters

One meter for liquids, gases and steam, with no moving parts and no impulse lines.

### Density and viscosity

Density, concentration, specific gravity and viscosity measured in line, in real time.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need differential pressure flow meters, or calibration for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote differential pressure flow meters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051SFA%20Annubar%20flow%20meter) [Calibration](https://its-ve.com/en/services/calibration/)