# Rosemount 8705, 8711 and 8750W magnetic flow meters

> Rosemount 8705, 8711, 8750W and 8721 magnetic flow meters for conductive liquids and slurries: no moving parts and no pressure drop. Request a quotation.

Source: https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Measurement](https://its-ve.com/en/products/measurement/)
- [Flow](https://its-ve.com/en/products/measurement/flow/)
- Magnetic flow meters

[Flow](https://its-ve.com/en/products/measurement/flow/)

Flow · Rosemount

# Rosemount magnetic flow meters

An unobstructed tube that measures by induction: the natural choice for water, slurries and conductive chemicals.

[Quote magnetic flow meters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208705%20magnetic%20flow%20meter) [Flow](https://its-ve.com/en/products/measurement/flow/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a magnetic flow meter?

A magnetic, or electromagnetic, flow meter measures the flow of conductive liquids, with a typical minimum conductivity of 5 µS/cm on the standard line. It does not work on hydrocarbons or gases. Its tube stays clear, with no moving parts and no pressure drop.

It applies Faraday’s law of induction: the sensor creates a magnetic field across the pipe and the moving liquid induces a voltage proportional to its velocity. Two electrodes pick it up and the transmitter converts it into flow.

- Conductive liquids only
- No moving parts, no pressure drop
- Separate sensor and transmitter
- In-place verification without removal

Models

## Rosemount magnetic flow meter models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

8705

### Rosemount 8705 flanged magnetic flow meter sensor

Flanged sensor with all-welded construction and a hermetic seal against moisture.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208705)

Fisher

8711

### Rosemount 8711 wafer magnetic flow meter sensor

Flangeless: a compact, lightweight and economical alternative to the flanged sensor.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208711)

Fisher

8750W

### Rosemount 8750W magnetic flow meter

Designed for water and wastewater in utility services.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208750W)

Fisher

8721

### Rosemount 8721 hygienic magnetic flow meter sensor

All-welded body for food, beverage and life sciences.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208721)

Fisher

MS

### Rosemount MS magnetic sensor for slurries

For sand, high solids content and long pulp fibers, paired with the 8782 transmitter.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20MS)

Fisher

8732E

### Rosemount 8732E field-mount magnetic flow transmitter

Dual-compartment housing, advanced diagnostics and a local operator interface.

[Magnetic flow meters](https://its-ve.com/en/products/measurement/flow/magnetic-flow-meters/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208732E)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The sensor coils generate the magnetic field and the electrodes, in contact with the liquid, measure the induced voltage. The inside of the tube is lined with an insulating material, and the combination of liner and electrodes is chosen for the chemistry, temperature and abrasiveness of the fluid.

To measure well, the pipe must be full and the flow profile stable: the manufacturer recommends five straight diameters upstream and two downstream. Proper grounding and distance from sources of electrical noise are part of the installation. The transmitters include a verification routine that checks meter health against its baseline without removing it from the pipe.

### Constructions and trim

- #### Flanged sensor (8705) All-welded construction with a hermetic seal, for demanding process service. Wide choice of liners and electrodes.
- #### Wafer sensor (8711) Installed between flanges, with no flanges of its own: compact, lightweight and economical.
- #### Water service (8750W) and hygienic (8721) The 8750W targets water and wastewater in utility services; the 8721, with a welded body, targets sanitary processes.
- #### Slurries and process noise (MS sensor and 8782 transmitter) For pulps, sand and suspended solids, where signal noise is the dominant problem.

Applications

## Where they are used

- Raw, treated and waste water, and cooling water
- Mineral slurries and pulps in mining and metals
- Stock and liquors in pulp and paper
- Acids, caustics and conductive chemicals with the right liner
- Produced and injection water in oil and gas

### Why it is chosen

- Full bore: no added pressure drop and nowhere for solids to build up
- No moving parts, with minimal maintenance
- Liners and electrodes for corrosive and abrasive fluids
- Meter verification in place, without stopping the process

### Worth weighing

- It only measures conductive liquids: not applicable to hydrocarbons, gases or steam
- Fluids that coat the electrodes can degrade the measurement; the pipe must stay full

ITS de Venezuela

## What ITS does with magnetic flow meters

We quote new Rosemount magnetic sensors and transmitters and their accessories, configure and commission the meter in the field, calibrate it through our calibration service, in the field and in the laboratory, and integrate it into the control loop. We reply with availability in Venezuela or Orlando. To quote, send the fluid and its conductivity, flow range, line size and flange class, pressure and temperature, solids content and output signal.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208705%20magnetic%20flow%20meter)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Flow Coriolis, magnetic, vortex and differential pressure.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Rosemount catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
Which fluids can a magnetic flow meter measure?
Conductive liquids: water, slurries, pulps, acids and caustics. The manufacturer states a typical minimum conductivity of 5 µS/cm. Hydrocarbons and gases produce no signal, so they need another technology.

How much straight run does it need?
For best performance, the manufacturer recommends a minimum of five pipe diameters upstream and two downstream. With less straight run the meter still operates, with a possible small shift in accuracy.

Flow

## More flow families

### Coriolis flow meters

Direct mass flow, with density and temperature from the same device, for liquids, gases and slurries.

### Vortex flow meters

One meter for liquids, gases and steam, with no moving parts and no impulse lines.

### Differential pressure flow

Annubar, compact and integral orifice, and orifice plates: standardized measurement for gas, liquid and steam.

### Density and viscosity

Density, concentration, specific gravity and viscosity measured in line, in real time.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need magnetic flow meters, or calibration for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote magnetic flow meters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%208705%20magnetic%20flow%20meter) [Calibration](https://its-ve.com/en/services/calibration/)