# Rosemount 1199 diaphragm seals and 3051S ERS remote sensors

> Rosemount 1199 and 1299 diaphragm seal systems and 3051S ERS electronic remote sensors for hot, corrosive or viscous fluids. Request a quotation.

Source: https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/

---
- [Home](https://its-ve.com/en/)
- [Products](https://its-ve.com/en/products/)
- [Measurement](https://its-ve.com/en/products/measurement/)
- [Pressure](https://its-ve.com/en/products/measurement/pressure/)
- Diaphragm seals

[Pressure](https://its-ve.com/en/products/measurement/pressure/)

Pressure · Rosemount

# Rosemount diaphragm seal systems

A diaphragm and a fill fluid between the process and the sensor: the way to measure hot, corrosive, viscous or solids-laden fluids.

[Quote diaphragm seal systems](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201199%20diaphragm%20seal%20system) [Pressure](https://its-ve.com/en/products/measurement/pressure/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a diaphragm seal system?

A diaphragm seal system protects the transmitter from hot, cold, corrosive, erosive or viscous processes. Rosemount fits it to differential, gage and absolute pressure transmitters, directly or with a capillary.

A thin diaphragm transmits pressure to the sensor through a fill fluid, leaving it isolated from the process. On tall columns and tanks, the electronic ERS system measures with two sensors and avoids capillaries and impulse lines.

- Isolates the transmitter from the process
- Direct, remote or balanced mounting
- Flanged and threaded seals
- Electronic alternative with no capillaries (ERS)

Models

## Rosemount seal system models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

1199

### Rosemount 1199 diaphragm seal system

Flanged and threaded seals for differential, gage and absolute pressure transmitters.

[Diaphragm seals](https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201199)

Fisher

1299

### Rosemount 1299 diaphragm seal system

Seal system to which Emerson lets you convert 1199 model codes.

[Diaphragm seals](https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201299)

Fisher

3051S ERS

### Rosemount 3051S ERS electronic remote sensor system

Two pressure sensors linked by an electrical cable: no capillaries and no impulse lines.

[Diaphragm seals](https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%203051S%20ERS)

Fisher

319

### Rosemount 319 flushing ring

Compact ring to clean the diaphragm without removing the seal.

[Diaphragm seals](https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20319)

Fisher

Thermal Range Expander

### Rosemount Thermal Range Expander

Extends the seal system range for extreme process and ambient temperatures.

[Diaphragm seals](https://its-ve.com/en/products/measurement/pressure/diaphragm-seal-systems/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20Thermal%20Range%20Expander)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

The system is filled and sealed at the factory: diaphragm, capillary, fill fluid and transmitter form a single assembly. The fill fluid is selected for the process and ambient temperatures, because its expansion and viscosity determine the temperature error and the response time.

System configuration matters as much as the transmitter. According to the manufacturer, tuned systems, with direct mounting on one side and a capillary on the other, reduce temperature effects by 10% to 20% and improve response time by 80% compared with traditional installations.

### Constructions and trim

- #### Direct mount The seal is coupled to the transmitter, with no capillary: the fastest response and the smallest ambient temperature effect.
- #### Remote mount and balanced systems The capillary separates the transmitter from the measurement point. Two equal capillaries form a balanced system for differential pressure and level.
- #### Thermal Range Expander and flushing rings The thermal range expander addresses temperatures up to 410 °C and as low as −75 °C. The 319 flushing rings clean the diaphragm without removing the seal.
- #### Electronic remote sensors (3051S ERS) Two synchronized sensors, linked by an electrical cable, calculate differential pressure. Heat tracing of capillaries and impulse lines is eliminated.

Applications

## Where they are used

- Corrosive, viscous or solids-laden fluids, or fluids that crystallize in impulse lines
- High-temperature processes beyond the limit of the transmitter
- Differential pressure level in pressurized tanks and distillation columns
- Vacuum and highly corrosive services
- Hygienic applications that allow no cavities or dead volumes

### Why it is chosen

- Isolates the sensor from the process without giving up continuous measurement
- Removes wet impulse lines and their maintenance
- A range of seals, diaphragm materials and fill fluids
- The ERS system improves response on tall vessels and avoids heat tracing

### Worth weighing

- Long capillaries add ambient temperature error and delay: length and fill fluid are calculated, not estimated
- The assembly is filled and sealed at the factory: it is not repaired in the field and must be specified complete

ITS de Venezuela

## What ITS does with seal systems

We quote new Rosemount seal systems, transmitters with seals and ERS systems, with their flushing rings and accessories; we install and commission the assembly in the field, calibrate it through our calibration service, in the field and in the laboratory, and integrate it into the control loop. We reply with availability in Venezuela or Orlando. To quote, send the fluid, process and ambient temperatures, pressure, measuring range, connection and flange size, distance between taps and diaphragm material, or the installed model code.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201199%20diaphragm%20seal%20system)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Pressure Gauge, absolute and differential transmitters.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Rosemount catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
When is an ERS system a better fit than capillaries?
The ERS system uses two independent pressure transmitters, so its range is specified for the maximum static pressure rather than the differential pressure. As a general guide it suits tall vessels and columns, where long capillaries suffer from ambient temperature; the manufacturer recommends sizing each application to know the actual accuracy.

What is the advantage of a capillary seal over impulse lines?
The seal isolates the transmitter from the fluid and replaces the impulse line with a filled, sealed capillary: it does not plug, does not freeze with the product and needs no purging. In exchange, the system must be calculated for the actual temperature and distance.

Pressure

## More pressure families

### Pressure transmitters

Gauge, absolute and differential pressure, Coplanar or in-line, with HART, fieldbus or wireless.

### Wireless pressure

Transmitters and gauges with WirelessHART for the points where running cable is not justified.

### Manifolds

Isolation, equalization and venting of the transmitter in one compact block, assembled and tested with it.

### Differential pressure level

Level from hydrostatic head, in open and pressurized tanks, with seals or remote sensors.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need diaphragm seal systems, or calibration for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote diaphragm seal systems](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%201199%20diaphragm%20seal%20system) [Calibration](https://its-ve.com/en/services/calibration/)
