# Pressure measurement: Rosemount transmitters

Gauge, absolute and differential pressure transmitters, with manifolds and remote seals.

[Quote pressure transmitters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20pressure%20transmitter) [Calibrate my instruments](https://its-ve.com/en/services/calibration/)

## How do you select a pressure transmitter?

Selection follows an order: pressure type (absolute, gauge or differential), range, accuracy, process contact, connection and accessories, and signal and approvals. A well-selected transmitter operates in the middle of its range and is calibrated with traceability.

With corrosive, viscous or hot fluids, a remote seal separates the sensor from the process; the manifold lets you isolate, equalize and vent the transmitter without stopping the process. Both are specified together with the transmitter.

## Pressure measurement

From the transmitter to the process tap: the measurement is only as good as its installation.

Pressure is the most measured variable in a plant and the basis of two others: flow by differential pressure and level by hydrostatic head. A Rosemount transmitter measures gauge, absolute or differential pressure and delivers it to the control system over a current loop, a fieldbus or a wireless network.

Around the transmitter there is an assembly that decides the outcome: the manifold that isolates and vents it, the diaphragm seal that protects it from hot, corrosive or viscous fluids, and the way pressure is carried from the tap to the sensor.

### What’s your challenge?

Plugged impulse lines, capillaries affected by temperature and mechanical gauges that fail without warning degrade the reading before the transmitter does.

### What’s your opportunity?

With the assembly properly specified, transmitter, manifold and seal, the measurement stays stable and is calibrated without stopping the process.

### Pressure transmitters

**Pressure transmitters.** Gauge, absolute and differential pressure, Coplanar or in-line, with HART, fieldbus or wireless.

- 3051
- 3051S
- 2051
- 2088
- 4051S
- 3051S MultiVariable

### Wireless pressure

**Wireless pressure.** Transmitters and gauges with WirelessHART for the points where running cable is not justified.

- 3051S
- 3051
- 2051
- Wireless Pressure Gauge
- Smart Pressure Gauge

### Manifolds

**Manifolds.** Isolation, equalization and venting of the transmitter in one compact block, assembled and tested with it.

- 305
- 306
- 304
- R305
- R306

### Diaphragm seals

**Diaphragm seals.** Remote seals and electronic remote sensors to measure where the transmitter cannot touch the fluid.

- 1199
- 1299
- 3051S ERS
- 319
- Thermal Range Expander

### Differential pressure level

**Differential pressure level.** Level from hydrostatic head, in open and pressurized tanks, with seals or remote sensors.

- 3051SAL
- 3051L
- 4051SLT
- 3051S ERS

Families

## Rosemount reference families

Pressure transmitters and differential-pressure level.

- ### 3051 Gauge, absolute and differential pressure transmitter.
- ### 3051S Scalable pressure transmitter platform.
- ### 2051 Pressure transmitter for general-purpose applications.
- ### 2088 Compact gauge and absolute pressure transmitter.
- ### 3051L Differential-pressure level transmitter with flanged seal.

Reference families of the brand. Give the exact model in your request: scope and availability are confirmed with each quote.

Selection guide

## Six steps to select a pressure transmitter

- ### Pressure type Absolute, gauge or differential.
- ### Range Normal operating pressure in the middle of the span; check the process overpressure limits.
- ### Accuracy What the loop requires, distinguishing reference accuracy from long-term stability, on span or on reading.
- ### Process contact Wetted-parts material and a remote seal for corrosive, viscous or hot fluids.
- ### Connection and accessories Process connection and manifold.
- ### Signal and approvals 4–20 mA HART, fieldbus or wireless; hazardous-area approvals and a periodic calibration plan.

Accessories

## Manifolds and remote seals

Manifolds let you isolate, equalize and vent the transmitter without stopping the process. Remote seals separate the sensor from corrosive, viscous, hot or solids-laden fluids. Both are specified together with the transmitter.

Calibration

## Calibration in the field and in the laboratory

ITS de Venezuela calibrates these instruments in the field and in the laboratory, certified under ISO/IEC 17025:2017. Each instrument is returned with its calibration certificate.

[See the calibration service](https://its-ve.com/en/services/calibration/)

Calibration scope

Pressure
Recorders, gauges and transmitters from 0 to 68.9 MPa

ISO/IEC 17025:2017

Brands

## Brands in this category

- [Rosemount Pressure and temperature](https://its-ve.com/en/brands/rosemount/)

Service

## Services for this equipment

What we do on this equipment in the shop and in the field.

- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### FIELDVUE and instrumentation Configuration, diagnostics and commissioning of controllers and instruments.
- ### Field service On-site support, shutdowns, commissioning and start-up.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
How do you select a pressure transmitter?
In this order: pressure type (absolute, gauge, differential), range with normal operation mid-span, required accuracy, material and seal for the fluid, process connection and accessories, output signal and approvals, and calibration plan.

Absolute, gauge or differential?
Gauge pressure is measured against the atmosphere; absolute, against vacuum, and is used where atmospheric pressure varies or in vacuum service; differential is the difference between two taps and is used for orifice-plate flow, level in pressurized tanks and pressure drop across filters.

How often is a pressure transmitter calibrated?
It depends on loop criticality, the transmitter’s specified stability and the plant’s quality or fiscal requirements: your metrology program sets the interval. What should be required is traceability, with calibration in a laboratory accredited under ISO/IEC 17025.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need a pressure transmitter or to calibrate yours?

Give us the pressure type, range, fluid, connection, signal and approvals, or the nameplate model.

[Quote pressure transmitters](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20pressure%20transmitter) [Calibration service](https://its-ve.com/en/services/calibration/)