[Temperature](https://its-ve.com/en/products/measurement/temperature/)

Temperature · Rosemount

# Rosemount temperature sensors: RTDs and thermocouples

Where the measurement begins: the sensor defines the accuracy, range and response of the whole temperature point.

[Quote temperature sensors](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20214C%20temperature%20sensor) [Temperature](https://its-ve.com/en/products/measurement/temperature/)

- Overview
- Models
- How it works
- Applications
- ITS
- Resources
- FAQ

## What is a process temperature sensor?

The sensor, also called a probe, is where temperature measurement begins. Process plants use two non-interchangeable technologies, the RTD and the thermocouple, which differ in signal, instrumentation, accuracy and range.

An RTD uses a resistive metal, almost always platinum for its accuracy and repeatability, whose resistance increases with temperature. A thermocouple measures the voltage at the junction of two different metals and withstands much higher temperatures and harsher environments.

- Platinum RTDs and thermocouples
- RTD: higher accuracy and stability
- Thermocouple: high temperature and vibration
- Paired with thermowell and transmitter

Models

## Rosemount temperature sensor models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Fisher

214C

### Rosemount 214C temperature sensor

The current line: Pt-100 RTDs and type J, K and T thermocouples, single or dual; pairs with the 114C thermowell.

[RTD and thermocouple sensors](https://its-ve.com/en/products/measurement/temperature/rtd-and-thermocouple-sensors/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20214C)

Fisher

68

### Rosemount 68 RTD sensor

Single-element Pt-100 RTD. Series declared obsolete by the manufacturer: its current replacement is quoted.

[RTD and thermocouple sensors](https://its-ve.com/en/products/measurement/temperature/rtd-and-thermocouple-sensors/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%2068)

Fisher

78

### Rosemount 78 RTD sensor

Single- or dual-element Pt-100 RTD. Series declared obsolete by the manufacturer.

[RTD and thermocouple sensors](https://its-ve.com/en/products/measurement/temperature/rtd-and-thermocouple-sensors/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%2078)

Fisher

183

### Rosemount 183 thermocouple

Type J, K, E or T thermocouple, single or dual. Series declared obsolete by the manufacturer.

[RTD and thermocouple sensors](https://its-ve.com/en/products/measurement/temperature/rtd-and-thermocouple-sensors/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20183)

Fisher

185

### Rosemount 185 thermocouple

Type J, K or N thermocouple with a DIN-style head. Series declared obsolete by the manufacturer.

[RTD and thermocouple sensors](https://its-ve.com/en/products/measurement/temperature/rtd-and-thermocouple-sensors/) [Quote this model](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20185)

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

## How it works

According to the manufacturer, the RTD offers higher accuracy, especially at lower temperatures, up to about 600 °C, and its response time depends on sensor size and construction. The thermocouple withstands temperatures up to 1800 °C depending on type, tolerates vibration better and responds fast.

The sensor is installed inside a thermowell or directly in the process, and connects to a transmitter that converts its low-level signal. Insertion length, sheath diameter, element type and head connection are defined in the model code.

### Constructions and trim

- #### Platinum RTD The most used element in general process temperature for its accuracy and stability. The Pt100 is the reference.
- #### Thermocouples A junction of two different metals. Types J, K and T cover most services; they are chosen by range and atmosphere.
- #### Rosemount 214C The current line: thin-film or wire-wound Pt-100 RTDs and type J, K and T thermocouples, in single or dual element.
- #### Earlier series: 68, 78, 183 and 185 The manufacturer declares them obsolete, but they remain in the installed base. Emerson offers a converter to move earlier model codes to the 214C.

Applications

## Where they are used

- General process temperature in lines, tanks and exchangers, with RTDs
- Furnaces, flue gases and high-temperature services, with thermocouples
- Equipment with vibration, where the thermocouple holds up better
- Precision measurement for energy balances and custody transfer, with an RTD matched to the transmitter
- Sensor replacement in existing thermowells

### Why it is chosen

- Platinum RTD: accuracy and repeatability across the range of most processes
- Thermocouple: wide range, ruggedness and fast response
- A range of lengths, sheaths and connections for new and existing thermowells
- With a transmitter, the signal is protected from noise and the sensor is diagnosed

### Worth weighing

- RTDs and thermocouples do not replace each other without reviewing the transmitter and the wiring
- Sensor length must match the thermowell: if it does not touch the bottom, the reading lags and deviates

ITS de Venezuela

## What ITS does with temperature sensors

We quote new Rosemount RTD and thermocouple sensors, alone or as an assembly with thermowell and transmitter, including the current replacement for discontinued series; we install and commission them in the field, calibrate sensors and transmitters through our calibration service, in the field and in the laboratory, and integrate the measurement into the control loop. We reply with availability in Venezuela or Orlando. To quote, send the sensor type, temperature range, insertion length, diameter, connection, whether it is single or dual and the thermowell it will go into, or the model code of the current sensor.

[Quote parts or repair](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20214C%20temperature%20sensor)
- ### Calibration Pressure, temperature, flow and volume, in the field and in the laboratory.
- ### Field service On-site support, shutdowns, commissioning and start-up.
- ### Automation and control Loops, actuation, re-engineering and equipment upgrades.

Resources

## Resources

The full category, the technical library and the manufacturer’s official documentation.

- Category ### Temperature Transmitters, RTD and thermocouple sensors, thermowells.
- Technical library ### Manuals, bulletins and selection guides Our own documents and official Fisher links for each family.
- Manufacturer ### Official Rosemount catalog (opens in a new tab) Product pages, bulletins and manuals on emerson.com.

FAQ

## Frequently asked questions

[All frequently asked questions](https://its-ve.com/en/faq/)
RTD or thermocouple?
It depends on the application. The RTD usually gives higher accuracy, especially at lower temperatures, up to about 600 °C. The thermocouple withstands much higher temperatures, up to 1800 °C depending on type, tolerates vibration better and responds fast thanks to its simpler construction.

Can an RTD and a thermocouple be used interchangeably?
Not usually. They differ in signal type, required instrumentation, accuracy and temperature range: the sensor is selected for the application.

Temperature

## More temperature families

### Temperature transmitters

They convert RTD and thermocouple signals into 4-20 mA, HART, fieldbus or wireless, and watch over sensor health.

### Thermowells

The well that protects the sensor from the process and lets it be removed without stopping the line, calculated against vibration.

### Non-intrusive and wireless temperature

Process temperature with no thermowell and no penetration, and wireless transmission for points without cable.

Trademark notice

Emerson, Fisher, FIELDVUE, ValveLink, Rosemount, Micro Motion, Crosby, Bettis and Hytork are registered trademarks owned by Emerson Electric Co. or its affiliates. ITS de Venezuela C.A. supplies products and provides services independently and does not claim to be the manufacturer or an authorized representative of these brands except where expressly stated with supporting documentation.

## Need temperature sensors, or calibration for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

[Quote temperature sensors](https://its-ve.com/en/request-a-quote/?modelo=Rosemount%20214C%20temperature%20sensor) [Calibration](https://its-ve.com/en/services/calibration/)