# Control valve inspection and diagnostics | ITS de Venezuela

> Visual and dimensional inspection, travel and seat-leakage tests, FIELDVUE signature testing and a condition report to decide whether to repair, restore the…

Source: https://its-ve.com/en/services/inspection-and-diagnostics/

---
- [Home](https://its-ve.com/en/)
- [Services](https://its-ve.com/en/services/)
- Inspection and diagnostics

[Services](https://its-ve.com/en/services/)

# Control valve inspection and diagnostics

Know the valve’s real condition before deciding: repair, restore the trim or replace.

[Request a diagnosis](https://its-ve.com/en/request-a-quote/?servicio=inspeccion) [Message on WhatsApp](https://wa.me/14074625160?text=Hello%20ITS%2C%20I%20would%20like%20information%20about%3A%20Inspection%20and%20diagnostics.)

- When it applies
- What we do
- What we deliver
- Related
- Cases and reading
- Frequently asked questions

When it applies

## When a diagnosis makes sense

In short

A diagnosis combines visual and dimensional inspection, travel and seat-leakage tests and, if the valve has a digital positioner, a signature test. The result is a report per tag with a recommendation: repair, restore the trim or replace.

- Seat leakage beyond the specified shutoff class, or packing leakage.
- Slow, erratic or oscillating loop response; hysteresis or dead band visible in the trend.
- Increasing noise or vibration at the valve or in the line.
- Before a plant shutdown, to decide which valves go to the workshop and with which parts.
- Equipment with no history, or after a change in process conditions.
- As part of a preventive plan defined by the criticality of each loop.

What we do

## How the service is carried out.

- 01 ### Identification Logged by tag, serial number and type from the nameplate. The serial number recovers the original factory configuration.
- 02 ### Visual and dimensional inspection Body, bonnet, packing, actuator and accessories; measurement of accessible components.
- 03 ### Travel test Full stroke, response to signal and actuator bench set.
- 04 ### Seat-leakage test Seat leakage compared with the specified shutoff class.
- 05 ### Signature test and diagnostics With FIELDVUE digital controllers: friction, dead band, air supply and response, interpreted with ValveLink.
- 06 ### Report and recommendation Findings per component and the proposed decision: repair, restore the trim or replace.

Deliverables

## What we deliver

- Condition report per tag, with photographs and measurements.
- Travel and seat-leakage test results.
- Signature-test plots when the valve has a digital positioner.
- Technical recommendation —repair, restore the trim or replace— with the list of parts required.

## What we need from you

With this information the quote is complete the first time.

- Loop tag, serial number and type from the nameplate (a photo of the nameplate is enough).
- Size, pressure class and materials, if known.
- Service conditions: fluid, inlet and outlet pressures, temperature.
- Observed symptom and since when.
- Positioner model and protocol (HART, fieldbus), if applicable.
- Whether the diagnosis is in the workshop or on site, and the available window.

[Send this information](https://its-ve.com/en/request-a-quote/?servicio=inspeccion)

Related

## Products this service covers

Fisher

DVC7K

### Fisher™ FIELDVUE™ DVC7K — Digital Valve Controller

High-performance digital valve controller with embedded prognostics and Advice at the Device™ technology, processing and analyzing data locally to deliver actionable information in real time.

Check availability

Fisher

DPC2K

### Fisher™ FIELDVUE™ DPC2K — Process Controller

Electro-pneumatic digital process controller with PID control, designed to replace pneumatic controllers on continuous single loops.

Check availability

Related categories

- [FIELDVUE](https://its-ve.com/en/products/final-control/valve-positioners/)
- [Control valves](https://its-ve.com/en/products/final-control/control-valves/)

Cases and reading

## Where we have done it, and what to read.

Projects · Chemical

### OXINOVA Plant

Client: Oxinova

Recovery of the installed Control Valve platform

Diagnostics

### FIELDVUE Online Diagnostics: Seeing the Failure Before It Happens

March 31, 2026 · 6 min read
The valve is already talking to you: friction, dead band, travel time. Online diagnostics turns those signals into planned maintenance instead of emergencies.

Diagnostics

### Fisher ValveLink Pro: diagnosing the DVC7K without being a specialist

April 7, 2026 · 5 min read
In 2026 Emerson released software that brings advanced diagnostics closer to the plant technician. What changes for teams that maintain DVC7K digital controllers.

## Frequently asked questions

When should a control valve be repaired?
When the valve no longer performs its function and the damage is in replaceable components. Typical indicators: seat leakage beyond the specified shutoff class, packing leakage, hysteresis or dead band measured in a signature test, slow or erratic actuator response, increasing noise or vibration, and loss of capacity against the nameplate rating.

Repair makes sense if the body is sound, the original sizing is still valid and parts are available. If the body is eroded or process conditions have changed, the right answer is to redesign or replace.

What does a valve diagnosis include?
Nameplate identification, visual and dimensional inspection, a travel test, a seat-leakage test and, with a digital positioner, a signature test. You receive a report per tag with photographs, results and the technical recommendation.

Can a valve be diagnosed without removing it?
Partly. With the valve in service, the online diagnostics of a FIELDVUE digital controller track friction, position deviation and air supply. A full signature test requires stroking the valve through its full travel, and trim condition and seat leakage can only be confirmed on the bench.

Other services

- [Control valve repair](https://its-ve.com/en/services/control-valve-repair/)
- [Trim restoration](https://its-ve.com/en/services/trim-restoration/)
- [FIELDVUE and instrumentation](https://its-ve.com/en/services/fieldvue-and-instrumentation/)

Industries

- [Refining and petrochemical](https://its-ve.com/en/industries/refining-and-petrochemical/)
- [Oil and gas](https://its-ve.com/en/industries/oil-and-gas/)
- [Power generation](https://its-ve.com/en/industries/power-generation/)

Genuine OEM
Genuine Fisher parts (OEM)

Genuine parts and kits identified by serial number, for B2B sales at factory prices with delivery in Venezuela.

[View Fisher parts](https://its-ve.com/en/products/final-control/fisher-oem-parts/) [Fisher OEM Parts ↗ (opens in a new tab)](https://fisheroemparts.acdamerica.net/?utm_source=its-ve)

## Which valves should be checked before the next shutdown?

Send the tag list and the symptoms; we will propose the scope of the diagnosis.

[Request a diagnosis](https://its-ve.com/en/request-a-quote/?servicio=inspeccion) [Message on WhatsApp](https://wa.me/14074625160?text=Hello%20ITS%2C%20I%20would%20like%20information%20about%3A%20Inspection%20and%20diagnostics.)