# Pressure regulator and relief valve service: set-point, testing, parts

> Selection, repair with OEM kits, tuning and set-point verification of Fisher pressure regulators, and maintenance of natural gas regulation trains and racks.

Source: https://its-ve.com/en/services/regulators-and-relief/

---
- [Home](https://its-ve.com/en/)
- [Services](https://its-ve.com/en/services/)
- Regulators and relief

[Services](https://its-ve.com/en/services/)

# Regulator and relief valve service

Regulators selected, repaired and tuned for their service conditions.

[Quote a service](https://its-ve.com/en/request-a-quote/?servicio=reguladores) [Message on WhatsApp](https://wa.me/14074625160?text=Hello%20ITS%2C%20I%20would%20like%20information%20about%3A%20Regulators%20and%20relief.)

- When it applies
- What we do
- What we deliver
- Related
- Cases and reading
- Frequently asked questions

When it applies

## When it applies

In short

ITS selects, repairs with OEM kits and tunes self-operated pressure regulators —pressure-reducing, backpressure and slam-shut— for gas, steam and liquids, and verifies their set-point before returning them to service.

- Delivery pressure drifts from set-point or oscillates with demand changes.
- Leakage at zero-flow lock-up or through the diaphragm.
- Scheduled maintenance of natural gas regulation trains and racks.
- Changed service conditions that require reviewing the regulator selection.
- Review of relief and overpressure shutoff devices associated with the train.

What we do

## How the service is carried out.

- 01 ### Selection and sizing Regulator checked against current pressures, flow and fluid; replacement proposed if it does not fit.
- 02 ### Inspection and disassembly Condition of diaphragm, springs, seat, orifice and pilot.
- 03 ### Repair with OEM kits Diaphragms, seats and seals replaced with genuine repair kits.
- 04 ### Tuning Reassembly and spring and pilot adjustment for the service condition.
- 05 ### Set-point verification Set pressure and lock-up checked before delivery.
- 06 ### On-site commissioning In the field: train put into service and verified with the process.

Deliverables

## What we deliver

- Regulator repaired and adjusted to the specified set-point.
- Record of set-point and lock-up verification.
- List of parts used with part numbers.
- Selection recommendation when the regulator does not fit the current service.

## What we need from you

With this information the quote is complete the first time.

- Regulator model and serial number (nameplate photo).
- Fluid and required inlet and outlet pressures.
- Minimum and maximum flow.
- Required set-point and service type: pressure-reducing, backpressure or overpressure shutoff.
- Size and connection type.
- Observed symptom.

[Send this information](https://its-ve.com/en/request-a-quote/?servicio=reguladores)

Related

## Products this service covers

Fisher

MR95

### Fisher™ MR95 — Pressure Regulator

Compact, direct-operated, high-capacity pressure-reducing regulator designed for a wide variety of industrial services: superheated steam, steam injection and tracing, nitrogen purge, boiler feedwater, process chemicals, cooling water and fuel lines, among others.

Check availability

Fisher

119EZ

### Fisher™ 119EZ — Fuel Gas Valve

Fuel gas valve for natural-draft burners in oil and gas applications, built on the compact, proven Type 119 platform with more than 25 years of service.

Check availability

Related categories

- [Regulators](https://its-ve.com/en/products/final-control/regulators/)
- [Pressure relief](https://its-ve.com/en/products/final-control/pressure-relief/)

Cases and reading

## Where we have done it, and what to read.

Projects · Oil & Gas

### Corocoro Project

Client: VHICOA

Rebuild, Metrology and Commissioning of Pressure Regulators

Projects · Steel

### Lime Plant — SIDOR

Client: API Int'l / SIDOR

Design, Engineering and Construction of a Natural Gas Regulation Rack

OEM parts

### Case Study: Power Plant Improves Safety with Fisher OEM Parts

May 19, 2026 · 5 min read
In power generation, a valve's safety function leaves no room for approximation. When the components are genuine, the safety instrumented function remains demonstrable.

## Frequently asked questions

What is set-point verification?
It is checking that the regulator delivers the specified set pressure and locks up correctly at zero flow. It is done after repair and, in the field, when the train is put back into service.

How often should regulators and relief devices be checked?
Frequency is set by the criticality of the service, the regulations that apply to the installation and the manufacturer’s recommendations. There is no single interval valid for every plant; each train’s history is the best data to adjust it.

Other services

- [Field service](https://its-ve.com/en/services/field-service/)
- [Control valve repair](https://its-ve.com/en/services/control-valve-repair/)
- [Instrument calibration](https://its-ve.com/en/services/calibration/)

Industries

- [Oil and gas](https://its-ve.com/en/industries/oil-and-gas/)
- [Steel and metals](https://its-ve.com/en/industries/steel-and-metals/)

Genuine OEM
Genuine Fisher parts (OEM)

Genuine parts and kits identified by serial number, for B2B sales at factory prices with delivery in Venezuela.

[View Fisher parts](https://its-ve.com/en/products/final-control/fisher-oem-parts/) [Fisher OEM Parts ↗ (opens in a new tab)](https://fisheroemparts.acdamerica.net/?utm_source=its-ve)

## Send the regulator nameplate.

With the model, pressures and set-point we will quote the repair or the selection of new equipment.

[Quote a service](https://its-ve.com/en/request-a-quote/?servicio=reguladores) [Message on WhatsApp](https://wa.me/14074625160?text=Hello%20ITS%2C%20I%20would%20like%20information%20about%3A%20Regulators%20and%20relief.)