FIELDVUE digital valve controller mounted on a control valve in a plant

Positioners and instruments · Fisher

Fisher level controllers

A submerged displacer turns level into a force, and the instrument converts it into the signal that moves the dump valve or reports to the control system.

What is a level controller?

A level controller is an instrument that uses analog, digital or pneumatic signals to measure, sense or control liquid level, the interface between two liquids or specific gravity (density) within a vessel.

The most widely used principle is the displacer: as the liquid rises, the buoyant force on the suspended cylinder increases and the instrument converts that change in force into a level signal. It allows throttling, on/off and gap control; a float offers only snap-acting or gap control.

Fisher level controller installed on a process vessel
  • Level, interface and density
  • Displacer sensor
  • Pneumatic, analog or digital output
  • Throttling, on/off or gap control

Models

Fisher level control models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

How it works

The displacer does not follow the surface like a float: it stays suspended and what varies is the buoyant force the liquid exerts on it. In interface service, that force changes with the position of the boundary between two liquids of different specific gravities. The instrument converts the change in force into its output, which throttles a dump valve, switches equipment or feeds the control system.

The output mode sets the models apart. The L2 is pneumatic and can run on natural gas, because its exhaust can be piped away; the L2e is electric and, together with a Fisher easy-Drive actuator, forms a fully electric level control loop; the L2t adapts to throttling or on/off control and arrives factory calibrated. The digital instruments and the 2500 are combined with a 249 sensor to meet mounting requirements.

Constructions and trim

  • L2 series (L2, L2e and L2t)

    Controllers with a displacer sensor for level or interface on separators and scrubbers: pneumatic, electric and FIELDVUE. The displacer is field-adjustable for vertical or horizontal operation.

  • FIELDVUE digital level controllers

    Microprocessor-based, communicating instruments that, with a 249 sensor, measure liquid level, interface level or density.

  • Fisher 2500 and 249 sensors

    Proportional-mode pneumatic controller and transmitter: it receives the change in level or interface from the buoyant force on the sensor displacer.

  • Level switches

    They sense high or low level and operate, electrically or pneumatically, the safety shutdown systems of field equipment.

Applications

Where they are used

  • Separators, treaters and scrubbers in natural gas production, compression and processing
  • Interface control between two liquids of different specific gravities
  • Process vessels with throttling level control
  • Fully electric level loops, with no instrument gas, using the L2e or L2t
  • High or low level alarms and shutdowns on field equipment

Why it is chosen

  • One measurement principle serves level, interface or density
  • Pneumatic, electric and digital versions on the same type of sensor
  • Throttling control with the L2t reduces equipment wear by avoiding the full-stroke cycling of discrete control
  • Zero-emission operation when combined with electric actuation

Worth weighing

  • The displacer is sized for the specific gravity of the fluids: a change of fluid means reviewing sizing and calibration
  • Deposits on the displacer and the condition of the suspension mechanism affect accuracy and require inspection

ITS de Venezuela

What ITS does with level controllers

We quote new Fisher level controllers and genuine parts (displacers, 249 sensor parts, torque tube assemblies, relays, gaskets and repair kits), repair and calibrate them in our Puerto Ordaz workshop and adjust them in the field on the vessel. We configure FIELDVUE instruments and evaluate the conversion of pneumatic loops to electric. Parts are managed through the Venezuela ↔ Orlando inventory. For a quotation, send the vessel type and its connection, the fluids and their specific gravities, the operating pressure and temperature, the required output and the nameplate model if it is a replacement.

Quote parts or repair
  • Calibration

    Pressure, temperature, flow and volume, in the field and in the laboratory.

  • Field service

    On-site support, shutdowns, commissioning and start-up.

  • FIELDVUE and instrumentation

    Configuration, diagnostics and commissioning of controllers and instruments.

Resources

Resources

The full category, the technical library and the manufacturer’s official documentation.

FAQ

Frequently asked questions

All frequently asked questions
Displacer or float?

A float rises and falls with the liquid surface and offers only snap-acting (on/off) or gap control. A displacer is a cylinder that stays suspended in the liquid: what changes is the buoyant force, and that also allows throttling control, with a digital, analog or pneumatic signal.

Can the interface between two liquids be controlled?

Yes. Displacer sensors detect liquid level or the interface of two liquids of different specific gravities, because the buoyant force changes with the position of the boundary between them. The displacer is sized according to the specific gravities of both fluids.

Positioners and instruments

More positioners and instruments families

FIELDVUE digital valve controllers

The instrument that positions the valve and also diagnoses it: it evaluates the performance and health of the assembly without shutting down the process.

Pneumatic positioners

They deliver air to the actuator until stem or shaft position matches the set point, with a pneumatic or 4-20 mA signal.

Process controllers

They close the loop in the field: they measure the variable, compare it with the set point and send the corrective signal to the final element.

I/P transducers

They convert the 4-20 mA electrical signal into a proportional pneumatic pressure: the link between the electronic loop and the air-operated valve.

Volume boosters and accessories

The accessories that complete the assembly: they speed up the stroke, report position, condition the air and define what the valve does if supply fails.

Fisher OEM Parts is the online catalog of ACD America Corp., our parent company. It opens in a new tab.

Need level controllers, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

Product bulletin

Loading the bulletin…

  1. 1Details
  2. 2Verification
  3. 3Request

Message us on WhatsApp

We verify your details and connect you with the specialist for your region.

Receive the phone code by

We will send one code to your email and another to your phone.