Pressure reducing regulators

Pressure reducing regulators. They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.
- MR95
- 67C
- 67D
- 627
- MR105
Final control · Category
Regulators for gas, steam and liquids: pressure-reducing, backpressure and slam-shut safety devices.
A self-operated regulator takes its energy from the process itself: a diaphragm and a spring compare the controlled pressure with the set point and move the plug with no external signal or air. It is simple, fast and needs no instrumentation.
When remote operation, set-point changes or integration with the control system are needed, a control valve with a positioner is used. Pilot-operated regulators cover the middle ground, with more accuracy and capacity than direct-operated ones.
Stable pressure using the energy of the process itself.
A self-operated regulator compares the controlled pressure with its set point and moves the plug without an external signal or air supply. Every regulator combines three elements: a restricting element (plug and orifice), a measuring element (the diaphragm that senses pressure) and a loading element (the spring or pilot that sets the target).
Depending on its function it holds the downstream or upstream pressure, feeds burners, reduces steam or shuts off the supply when pressure leaves its limits. Emerson groups the Fisher catalog into pressure reducing regulators, back pressure regulators, slam-shut devices and steam regulators; pilot-operated regulators for natural gas and fuel gas valves are presented here as well.
A poorly sized regulator hunts, is noisy or fails to reach set pressure when demand changes.
Selected by function, flow and spring range, it holds pressure without instrumentation or external power.

Pressure reducing regulators. They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

Pilot-operated regulators for natural gas. A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

Back pressure regulators and relief. They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

Fuel gas valves. They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

Slam-shut devices. They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

Steam regulators. They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.
Fisher models
Each model with its official technical bulletin, which you can read right here, and a quote one click away.
Pressure-reducing regulator
Adjustable regulators that cut LP-gas tank pressure to an intermediate level. The 64SR adds internal relief, and the 64KB has a PTFE diaphragm protector suited to anhydrous ammonia.
Pressure-reducing regulator and vacuum service equipment
Direct-operated regulators for precise control of low-pressure industrial gases, as in burners and tank blanketing, plus vacuum service equipment as vacuum regulators or vacuum breakers.
Instrument supply pressure-reducing regulator
Direct-operated regulators and filter regulators that deliver steady reduced pressure to pneumatic and electropneumatic controllers and other instruments. Suitable for most air or gas service.
Pressure-reducing regulator
Compact-body high-pressure regulator for LP-gas in liquid or vapor service, offered with wrench, handwheel, calibrated dial or tamper-resistant fixed spring adjustment.
Pressure-reducing regulator
Direct-operated regulators and filter regulators that deliver constant reduced pressure of gaseous fluids to pilot-operated controllers and other pneumatic instrumentation. Compact design.
Pressure-reducing regulator
Gas regulator with a Type 61 pilot mounted on the actuator casing, for distribution, industrial and commercial use. It accepts inlet pressures up to 1000 psig (69 bar).
Fuel gas switching valve
Valve for on-off or throttling control of noncorrosive gases at low pressure. The 119EZ and 119EZS versions feed natural-draft burners and tune the opening speed for safe ignition of the main flame.
Pressure-reducing regulator
Direct-operated regulator that supplies gas to furnaces, burners and other industrial and commercial appliances. Its balancing system keeps pressure steady despite varying inlet pressure.
Pilot-operated pressure-reducing regulator
Series of pilot-operated regulators for distribution, industrial and commercial use, with inlet pressures up to 175 psi. Versions are available with supply shutoff or with internal relief for thermal expansion.
Fuel gas pressure regulator
Regulator for high-pressure, fast-response duty such as fuel gas supply to a gas turbine. It carries a Type 32A pilot and works for pressure reducing or wide-open monitoring, with high capacity.
Pressure-reducing regulator
Direct-operated pressure-reducing regulators for low and high-pressure systems, suitable for natural gas, air and other gases. Performance varies with the construction selected.
Pilot-operated pressure-reducing regulator
Pilot-operated regulator intended for fixed-factor pressure measurement. It ships with a factory-installed 6351F pilot and external registration, so it needs a downstream control line.
Pressure-reducing regulator
Spring-loaded, direct-operated regulator in NPS 1 and 2 bodies for natural gas, air and other gases. Used as a first-stage farm-tap or high-pressure industrial regulator, and convertible to a relief valve in the field.
Panel-mounted loading regulator
Compact, rugged unit used mainly to load pressure-balanced gas regulators by hand. It also gives manual control of control valves fitted with diaphragm actuators.
Automatic changeover manifold
High-capacity assembly for commercial and industrial use that switches by itself from the supply cylinder to the reserve one when gas runs out. It combines two 64 Series regulators and a Type 803 direct indicator.
Pressure-reducing regulator
UL-listed direct-operated, spring-loaded regulator for LP-gas service and industrial installations, with limited-capacity internal relief across the diaphragm.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for service and industrial installations. Its limited-capacity internal relief bleeds excess pressure through the vent.
Pilot-operated pressure-reducing regulator
Regulators for pressure control in natural gas distribution, fuel supply to boilers, furnaces and mixers, and large commercial buildings. They also serve in plant air and liquid service.
Low-pressure gas blanketing regulator
Pilot-operated pressure-reducing valve with a supply pressure regulator, used for very accurate control of gas blanketing systems at very low pressures. It uses a quick-change trim package.
Vapor recovery regulator
Self-contained, pilot-operated regulator system for handling blanketing gas in vapor recovery schemes. It includes a quick-change trim package to ease maintenance.
High-pressure regulator
Self-operated high-pressure regulators that reduce gas for use as pilot supply pressure in pilot-operated regulators or loading pressure in pressure-loaded regulators. Also used as general high-pressure reducers.
Direct-operated pressure-reducing regulator
Direct-operated regulators that resist hydrate formation and freeze-up, used on high-pressure lines from wellheads and separators. Suitable for natural gas, air, propane and other gases.
High-pressure instrument supply system
System of filters, regulators and relief valves that takes pressure of up to 2000 psig and reduces it to the controlled pressure a pneumatic instrument needs, with overpressure protection included.
Tank blanketing valve
Stainless steel pilot-operated valve for accurate pressure control in low-pressure blanketing systems, with a very large rolling-diaphragm actuator and a single adjusting screw.
Tank blanketing valve
Direct-operated stainless steel valve for low-pressure blanketing. Its oversized diaphragm actuator makes it highly sensitive to changes in tank pressure.
Tank blanketing valve
Self-contained, fully balanced, pilot-operated valve for accurate pressure control in tank blanketing systems. It helps control emissions and protects against atmospheric contamination.
Residential gas regulator with safety shutoff
Direct-acting, spring-loaded regulator with reinforced safety for residential, commercial and industrial use. A shutoff valve trips on excess flow or pressure drop and can be reset manually.
Throttle valve for station bypass
Throttle valves that act as a bypass in transmission stations, reducing pressure up to 100 bar. The BLX version includes an OS2 release relay that cuts off flow on outlet overpressure.
Pressure-loaded pressure-reducing regulator
Series of pressure-loaded regulators for commercial and institutional installations, with many connection sizes, outlet pressures and orifices. Its accurate control suits fixed-factor measurement applications.
Pressure-loaded pressure-reducing regulator
Series of pressure-loaded regulators for light industrial and commercial installations, with accurate control suited to fixed-factor measurement. Options include several connections, materials, orifices and overpressure protection.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for commercial and light industrial installations. The actuator rotates a full 360 degrees through a union ring on the body, easing installation and maintenance.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for commercial and light industrial applications, with several body, connection and orifice sizes and overpressure protection options.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for commercial and light industrial applications, with several body and orifice sizes, internal or external registration and overpressure protection options.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for commercial and light industrial sites, offered in several body sizes, with internal or external pressure registration and overpressure protection options.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator with many body, connection and outlet pressure options using external registration, plus overpressure protection alternatives, including slam-shut.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator built for many pressure-reducing duties, with a range of connections and outlet pressures using external registration, and optional overpressure protection.
Pressure-reducing regulator
Pilot-operated, balanced, soft-seated regulators for high-pressure city-gate stations, large distribution systems and power plant feeds. EZH is spring-to-close and EZHSO is spring-to-open.
Pilot-operated pressure-reducing regulator for low pressure
Pilot-operated, pressure-balanced, soft-seated regulator for natural gas distribution in district stations and commercial or industrial meter sets. It gives low differential and tight shutoff.
Pressure-reducing regulator
Pilot-operated regulator for natural gas networks and industrial or commercial sites, with tight shutoff. The EZROSX version adds a slam-shut device that reacts to over or under pressure.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for natural, manufactured or liquefied gas in residential, commercial and industrial use. Internal relief limits overpressure and it meets ANSI B109.4/CGA 6.18.
Pressure-reducing regulator
UL-listed second-stage regulator for two-stage LP-gas systems, with capacity up to 2,600,000 BTU/hr (29.27 SCMH), suited to commercial applications.
Pressure-reducing regulator
High-capacity self-operated regulator with a balanced port and optional integral slam-shut, for district stations and industrial loads such as driers, furnaces, boilers and burners.
Slam-shut safety valve
Slam-shut valve that quickly cuts gas flow on overpressure or underpressure, with positive shutoff and high shock and vibration resistance. Top entry allows in-line maintenance.
LP-gas first-stage regulator
First-stage regulator for domestic two-stage LP-gas systems, UL listed and suited to tight installations. Stainless steel internal parts give a recommended replacement life of 20 years.
Changeover manifold regulator assembly
Changeover assembly made of two 67C regulators and a special gauge that shows when the supply cylinder has switched to the reserve. The R130-20 delivers 45 psig on supply and 30 psig on reserve.
LP-gas second-stage regulator
UL listed regulator for two-stage LP-gas systems that lowers the first-stage pressure, usually 10 psig, to 11 inches water column. Its compact size suits tight fit installations.
LP-gas first-stage regulator
UL listed first-stage regulator for LP-gas systems with a small footprint for underground tanks or limited dome space. It offers multiple end connections, adjustable springs and corrosion resistant materials.
Integral two-stage regulator
UL listed regulator for LP-gas systems with small domestic loads that reduces tank pressure to 11 inches water column through an integral two-stage system. Its compact size suits tight installations.
Integral two psig service regulator
UL listed regulator for LP-gas systems with small domestic loads that reduces tank pressure to 2 psig through an integral system. Its compact size suits tight installations.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for economical pressure reduction in residential, commercial and industrial uses. It works with natural, manufactured or liquefied petroleum gas.
LP-gas second-stage regulator
UL-listed second-stage regulators that reduce the outlet pressure of a first-stage regulator in domestic installations. The R622 includes a relief valve and screened vent; the R642 and R652 have an angle body.
2-PSI LP-gas service regulator
UL-listed regulators for 2-PSI LP-gas systems, installed after the first-stage regulator. They supply about 2 psig to a line regulator inside the building and carry a white closing cap for identification.
Pressure-reducing regulator
UL-listed (Underwriters Laboratories) first-stage regulator for two-stage LP-gas systems. It reduces tank pressure to 10 psig (0.69 bar) ahead of the second-stage regulator.
Pressure-reducing regulator
UL-listed integral two-stage regulator for LP-gas systems, taking tank pressure down to 11 inches w.c. (27.4 mbar), with screened vents on both stages.
Integral two psig service regulator
UL listed regulator for two psig service LP-gas systems that reduces tank pressure to 2 psig in a single unit. The first-stage vent points downward and the second-stage vent sits over the outlet.
Second-stage LP gas regulator
Second-stage regulators that reduce the outlet pressure from a first-stage regulator in domestic LP gas installations. Versions come in straight or angle bodies, and with settings down to 2 psig.
Pressure-reducing regulator
Direct-operated, spring-loaded regulator for corrosive environments in residential and small commercial uses. It reduces gas distribution pressures to a range from 4.5 inches w.c. to 2.5 psig.
Tank blanketing regulator
Spring-loaded, direct-operated regulator that holds a slight positive pressure over the stored liquid. This keeps it from vaporizing to atmosphere, lowers its combustibility and protects it from oxidation and contamination.
Balanced tank blanketing regulator
Direct-operated regulator with a fully balanced plug that reduces sensitivity to inlet pressure. Its large diaphragm accurately controls tank pressure at low settings in blanketing systems.
Vacuum breaker
Vacuum breaker for precise control in small-capacity, low-pressure service where a rise in vacuum must be limited. It shares spare parts with other products in the T205 Series.
Tank blanketing vapor recovery regulator
Direct-operated regulator that senses a rise in vessel pressure and vents the excess to a vapor recovery system. It can also serve as a backpressure regulator or relief valve.
Vacuum regulator
Direct-operated vacuum regulator for cases where a decrease in vacuum must be limited, such as between a tank and the vacuum source to control tank vacuum. It has a tamper-resistant adjustment.
Pressure-reducing regulator
Economical direct-operated, spring-loaded regulator for residential, commercial and industrial pressure reduction. It fits cabinets or underground modules and offers an integral slam-shut option.
Slam-shut safety valve
Slam-shut family that cuts gas to the downstream system when outlet pressure rises above or falls below the set limits. The VS110 uses the VSX4 device and the VS120 the VSX8.
Pressure-reducing regulator
Series of regulators with a large diaphragm area that gives good accuracy at low-pressure settings. The Y600A and Y600AR include a pitot tube for added capacity; the Y600AM uses external registration.
Vacuum service and relief equipment
Family for vacuum and relief service: the Y610A works as a vacuum breaker, the Y611A as a vacuum breaker or relief valve and the Y612A as a vacuum regulator. It allows fine control at low pressure settings.
Gas blanketing regulator
Self-operated regulator with internal registration, requiring no downstream control line. It is used for accurate control of very low-pressure blanketing systems, keeping positive pressure in the vessel.
Vacuum breaker
Limits a rise in vacuum within a system. When vacuum exceeds the value sensed on the diaphragm, it opens and admits atmosphere or positive pressure to bring the controlled vacuum back to its original setting.
Gas blanketing regulator
Direct-operated regulator for accurate pressure control in low-pressure gas blanketing systems. Its balanced plug gives accuracy comparable to that of a pilot-operated regulator.
Vacuum regulator
Vacuum regulators for cases where a decrease in vacuum must be limited, for example between a tank and the vacuum source. When vacuum drops, the diaphragm opens the seat and returns the system to set point.
Pressure-reducing regulator for liquids
Regulator for liquid service fitted with a Type 6492H or 6492L pilot. Downstream pressure acts on the main valve pistons and then on the pilot diaphragm.
Liquid pressure-reducing regulator
Direct-operated pressure-reducing regulators for liquid service. They come in three body sizes, NPS 3/4, 1 and 2, and in construction materials matched to the application.
Pressure-reducing regulator for liquids
Pilot-operated regulator for liquid service with smooth operation, tight shutoff and long life, even in dirty service. Its internal metal plug and inlet strainer protect the seat from debris.
Liquid pressure-reducing regulator
High-capacity, direct-operated regulator for liquid, air and gas. It suits cases needing fast response or fluids carrying impurities, such as lube oil, cooling water and pump bypass.
Steam pressure-reducing valve
Steam reducing valve for dirty environments with stable control. It serves as the main pressure reducer in industrial heating on heat exchangers, evaporators, digesters and reactors.
Self-operated steam regulator
Cost-effective steam pressure reducer, with a Type 6392 pilot that uses inlet pressure as its operating medium, or without pilot as a pressure-loaded regulator for remote setpoint adjustment.
Steam pressure-reducing valve
Steam pressure-reducing valve for process heating such as heat exchangers, evaporators, digesters and reactors. It copes with dirty environments and its trim is replaced using a drop-in kit.
Pilot-operated steam regulator
Piston-actuated self-operated valve for high-cycle steam, with lapped seating surfaces and bellows-sealed pilots. It reaches 250 psig (17.2 bar) and 650°F (343°C).
Regulator pilot
Series of pilots for 1098-EGR and EZL regulators, with counterparts for the 99 Series. Styles cover low, high and extra-high pressure, with different proportional bands and standard or high-temperature materials.
Regulator pilot
Pilots paired with several main valves in pressure-reducing, relief or back-pressure applications. All work in gas service and, except the 6351, in liquid service as well.
Direct-operated pressure-reducing regulator
Compact, large-capacity regulator for superheated steam, steam tracing, nitrogen purging, boiler feed water, process chemicals, cooling water, autoclaves and pneumatic supply.
Sanitary pressure-reducing regulator
Compact, large-capacity, self-operated regulator for sanitary applications in pharmaceutical, biotech and food. Offered in NPS 1/2 to 3 with Tri-Clamp connections, for steam, liquid or gas.
Back-pressure regulator and relief valve
Pilot-operated relief valve for liquid and gas service, also suited to back-pressure or bypass throttling. Its quick-change trim speeds up maintenance and it accepts wireless position monitors.
Pilot-operated backpressure regulator
Relief valve or backpressure regulator for gas, liquid or steam. With EPDM or FFKM it handles up to 550°F (288°C) with Class VI shutoff, and other elastomers are available for corrosive service.
Vapor recovery regulator
Responds to changes in blanket gas pressure and throttles open or closed to control the gas leaving the vessel, working at very low set points.
Relief valve or backpressure regulator
Spring-loaded relief valves that act as downstream pressure regulators to protect the system from overpressure. A large diaphragm gives sensitivity at low settings, and they are not ASME safety relief valves.
Pilot-operated relief valve or backpressure regulator
Pilot-operated relief valve that protects downstream systems from overpressure on natural gas, air, propane or other non-corrosive media. It needs very little buildup over set pressure to open fully.
Backpressure regulator and relief valve
Relief valves for farm taps, installed between first-stage and second-stage regulators, suited to natural gas, air or propane, with relief settings from 5 to 125 psig (0.34 to 8.6 bar).
Pilot-operated relief valve
Low-cost relief valve made of a 1805P main valve and a 6358 pilot, in NPS 2, with settings from 10 to 100 psig (0.69 to 6.9 bar) in three ranges, adjusted at the pilot screw.
Pilot-operated backpressure regulator
Compact backpressure regulators or relief valves in globe (1808) or angle (1808A) body, used to hold pressure on oil and gas separators and in gas distribution systems.
Pilot for backpressure regulators
Pilots that pair with several main valves in relief and backpressure applications and work in both gas and liquid service.
Backpressure regulator
Holds backpressure on LACT custody-transfer skids so the positive-displacement pump or Coriolis meter can measure accurately and upstream skid equipment stays protected.
Pilot-operated relief valve or backpressure regulator
Pilot-operated unit that protects against overpressure in city gate and district stations, or works as a backpressure regulator in commercial and industrial use. It runs smoothly and quietly, even in dirty service.
Relief valve or backpressure regulator for liquids
Pilot-operated unit for liquid service that works as a relief valve or backpressure regulator, with smooth operation and tight shutoff. An internal strainer keeps large particles out of the main valve.
Back-pressure and relief regulator
Series for back-pressure or relief duty in liquid, gas, air and steam service, with direct-operated spring-loaded models. The D versions add pressure loading to hold differentials or adjust setpoint remotely.
Direct-operated back-pressure regulator
High-capacity, general-purpose back-pressure regulator for liquid, air and gas. It suits lube oil systems and applications where response speed, minimum differential or impure fluids matter.
Sanitary backpressure regulator
Compact, large-capacity backpressure regulator for applications where sanitary design is essential, such as pharmaceutical, biotech and food. Fits Tri-Clamp connections in NPS 1/2 to 3 for steam, liquid or gas.
Vapor recovery regulator
Direct-operated regulator with internal registration and no downstream control line. It senses rising vessel pressure and vents the excess to a vapor recovery or disposal system.
No model matches your search. Send us the model and we will quote it.
Manufacturer photos and technical bulletins. Fisher and FIELDVUE are marks of Emerson.
Models
Description, features and a link to the manufacturer’s official documentation.
Fisher
MR95
Compact, direct-operated, high-capacity pressure-reducing regulator designed for a wide variety of industrial services: superheated steam, steam injection and tracing, nitrogen purge, boiler feedwater, process chemicals, cooling water and fuel lines, among others.
Fisher
119EZ
Fuel gas valve for natural-draft burners in oil and gas applications, built on the compact, proven Type 119 platform with more than 25 years of service.
Applications
Superheated steam, steam injection and tracing, nitrogen purge, boiler feedwater, process chemicals, cooling water and fuel lines.
In direct-reduction plants and gas production, regulators are built into regulation racks designed for the flow and pressure of each consumer.
Brands
Service
What we do on this equipment in the shop and in the field.
Maintenance of pressure regulators and relief devices.
Valve condition assessment before deciding to repair or replace.
Projects
A self-operated regulator uses process energy and needs no signal or air: it is simple and fast. A control valve with a positioner allows remote operation, set-point changes and integration with the control system. Pilot-operated regulators offer more accuracy and capacity than direct-operated ones.
It is a safety shutoff device that cuts the gas supply quickly and completely when downstream pressure goes outside the set limits. It is reset manually once the cause is corrected and protects equipment and burners downstream of the regulator.
Give us the fluid, inlet and outlet pressures, flow and connection size, or the nameplate model.