Fisher
EZH / EZHSO
Fisher EZH and EZHSO Series regulators
Pilot-operated, pressure-balanced and soft-seated for high-pressure gas transmission; spring-to-close or spring-to-open.
View bulletin
Regulators · Fisher
For gas transmission, distribution and supply stations where flow is high and outlet pressure must stay steady at any demand.
A pilot-operated regulator uses a small regulator, the pilot, to drive a main valve. The pilot amplifies slight changes in outlet pressure, which gives more capacity and holds pressure closer to set point than a direct-operated regulator.
That is why it dominates in natural gas: transmission and city gate stations, large-capacity distribution, power plant feeds and fuel gas for boilers and furnaces. The Fisher EZH, EZR and 1098-EGR Series and the Type 99 cover that range.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
EZH / EZHSO
Pilot-operated, pressure-balanced and soft-seated for high-pressure gas transmission; spring-to-close or spring-to-open.
View bulletin
Fisher
EZR
Accurate, smooth, quiet operation with tight shutoff, even in dirty service.
View bulletin
Fisher
1098-EGR
Economical, accurate control in gas distribution and fuel gas; also in plant air and liquid service.
View bulletin
Fisher
99
Type 61 pilot integrally mounted on the actuator casing, for distribution, industrial and commercial use.
View bulletinBrand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
The pilot measures downstream pressure and compares it with its spring. When demand increases and pressure falls, the pilot changes the loading pressure on the actuator or diaphragm of the main valve and it opens; as pressure recovers, the pilot returns it toward closure. Because the pilot reacts to very small variations, the main valve covers its full travel with minimal deviation from set point.
In these designs the gas bled by the pilot is routed to the downstream line instead of being vented: for the EZH and the 1098-EGR Emerson states that the pilot-operated system bleeds 100% of the gas to the downstream system. The knife-edged metal plug against a soft seat gives bubble-tight shutoff in dead-end systems, and the optional Whisper Trim cage attenuates noise at the source.
Pressure-balanced and soft-seated. The EZH is spring-to-close to protect downstream assets; the EZHSO is spring-to-open to maintain supply. The manufacturer publishes the same 1500 psig (103 bar) rating on inlet and outlet.
The metal plug deflects particles away from the diaphragm and a stainless steel inlet strainer protects it. With travel indicator and an EZROSX version with integrated slam-shut.
Top entry: trim is inspected, cleaned and replaced without removing the body from the line. According to the manufacturer it controls at differentials as low as 1 psid (70 mbar).
Type 61 pilot mounted on the actuator casing and three pilots to choose from. The manufacturer states inlet pressures up to 1000 psig (69.0 bar).
Applications
ITS de Venezuela
ITS quotes new Fisher pilot-operated regulators, their pilots and their genuine parts (diaphragms, plugs, seats, cages, seals and pilot kits), and services installed stations: disassembly, inspection, soft parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, and field maintenance of regulating trains, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: gas and its composition if it is not natural gas, maximum and minimum inlet pressure, outlet pressure, maximum and minimum flow, temperature, line size and connections, and whether a monitor or slam-shut is required; or the model and serial number from the nameplate.
Quote parts or repairMaintenance of pressure regulators and relief devices.
On-site support, shutdowns, commissioning and start-up.
Valve condition assessment before deciding to repair or replace.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Pressure-reducing, backpressure, fuel gas and slam-shut.
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
It is two regulators in series. The worker controls pressure in normal operation; the monitor, set slightly higher, stays open and takes over if the worker fails open. Emerson notes that combining an EZHSO as worker, which is spring-to-open and favors continuity, with an EZH as monitor, which is spring-to-close and protects assets, brings together the advantages of both failure modes.
By accuracy and flow. The direct-operated regulator is simple, robust and economical, and is enough when some pressure drop under load is acceptable. The pilot-operated regulator holds pressure closer to set point and handles larger flows, so it is chosen for gas stations and large consumers. The final decision comes from sizing with the actual pressures and flow.
Regulators

They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

They control upstream pressure: they stay closed up to set point and pass only the excess to the return line, another pressure level or the vent.

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.