Fisher
MR98
Fisher MR98 Series backpressure regulators and relief valves
Backpressure or relief in liquid, gas, air and steam; spring-loaded types or with additional pressure loading.
View bulletin
Regulators · Fisher
The regulator that looks backward: it holds the pressure of the system upstream of it and limits pressure buildup, with no external power.
A back pressure regulator controls upstream pressure: it stays closed while inlet pressure is below set point and opens to discharge the excess when pressure rises above it. It is the inverse of a pressure reducing regulator.
Installed on a branch, the same mechanism serves as relief. The Fisher MR98 Series covers liquid, gas, air and steam: Types MR98L, MR98H and MR98HH are spring-loaded, and Types MR98LD, MR98HD and MR98HHD add pressure loading for a differential or a remote set point.
Models
Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.
Fisher
MR98
Backpressure or relief in liquid, gas, air and steam; spring-loaded types or with additional pressure loading.
View bulletin
Fisher
MR108
Direct-operated and high-capacity for liquid, air and gas; common on lube oil systems.
View bulletin
Fisher
63EG
Pilot-operated relief for liquid and gas, also suited to backpressure or bypass duty; quick-change trim.
View bulletin
Fisher
1808 / 1808A
Pilot-operated, compact and economical, globe-style (1808) or angle-style (1808A), for oil and gas separators.
View bulletin
Fisher
1805
Relief for farm tap gas installations, between the first-stage and second-stage regulators.
View bulletin
Fisher
289
Spring-loaded throttling relief for low-pressure settings downstream of regulators.
View bulletinBrand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.
How it works
Inlet pressure acts under the diaphragm against the force of the spring, which holds the plug closed. Above the setting, the diaphragm lifts the plug and the regulator discharges; when pressure returns to set point, it closes. Unlike a safety valve, it modulates: it opens in proportion to the excess pressure and works continuously.
Additional pressure loading on the diaphragm turns the regulator into a differential device: it holds a constant difference between the controlled pressure and a reference pressure, as a compressor seal or a lubrication system requires. When the flow to be discharged is large, the pilot-operated construction gives more capacity with less pressure buildup above the setting.
Direct-operated Types MR98L, MR98H and MR98HH, with elastomer seats for tight shutoff, graphite gaskets and constructions for arctic and cryogenic temperatures.
Types MR98LD, MR98HD and MR98HHD for differential relief, backpressure against a reference or remote set point adjustment.
Direct-operated with a pressure-loaded actuator, for liquid, air and gas. The manufacturer indicates it for lube oil and for services where speed of response is critical or the fluid is not free of impurities.
Relief or backpressure with a pilot for high flows and low buildup: the 63EG, top entry with quick-change trim; the 1808 and 1808A, compact, for oil and gas separators.
Applications
ITS de Venezuela
ITS quotes new Fisher back pressure and relief regulators and their genuine parts (diaphragms, springs, plugs, seats and gaskets), and services installed ones: disassembly, inspection, soft parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, plus field service, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: fluid, pressure to be held upstream, pressure at the outlet, maximum and minimum flow to be discharged, temperature, connection size and type, and whether control is differential; or the model and serial number from the nameplate.
Quote parts or repairMaintenance of pressure regulators and relief devices.
Valve condition assessment before deciding to repair or replace.
On-site support, shutdowns, commissioning and start-up.
Resources
The full category, the technical library and the manufacturer’s official documentation.
Category
Pressure-reducing, backpressure, fuel gas and slam-shut.
Technical library
Our own documents and official Fisher links for each family.
Manufacturer
Product pages, bulletins and manuals on emerson.com.
The back pressure regulator is a control device: it modulates continuously to hold upstream pressure at set point. The safety valve is a protection device: it stays closed in operation and opens only on overpressure, with the capacity required by the equipment code. A well-designed system usually has both, with the regulator set below the safety valve.
It lets the regulator hold a differential pressure instead of a fixed pressure. The reference pressure is connected above the diaphragm and adds to the spring, so the controlled pressure follows the reference with a constant difference. It also allows the set point to be changed remotely by varying that loading pressure.
Regulators

They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.
Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.