Process plant lit at dusk, a typical service for back pressure regulators

Regulators · Fisher

Fisher back pressure regulators and relief

The regulator that looks backward: it holds the pressure of the system upstream of it and limits pressure buildup, with no external power.

What is a back pressure regulator?

A back pressure regulator controls upstream pressure: it stays closed while inlet pressure is below set point and opens to discharge the excess when pressure rises above it. It is the inverse of a pressure reducing regulator.

Installed on a branch, the same mechanism serves as relief. The Fisher MR98 Series covers liquid, gas, air and steam: Types MR98L, MR98H and MR98HH are spring-loaded, and Types MR98LD, MR98HD and MR98HHD add pressure loading for a differential or a remote set point.

Process plant lit at dusk, a typical service for back pressure regulators
  • Controls upstream pressure
  • Liquid, gas, air and steam
  • MR98: set pressures to 400 psig (27.6 bar)
  • Spring-loaded, pressure-loaded or pilot-operated

Models

Fisher back pressure and relief models

Manufacturer reference models for this type. Tell us the exact model or attach the nameplate: scope and availability are confirmed with each quotation.

Brand reference models per the manufacturer’s catalog. ITS quotes new valves and genuine parts to order; it does not publish stock or prices.

How it works

How it works

Inlet pressure acts under the diaphragm against the force of the spring, which holds the plug closed. Above the setting, the diaphragm lifts the plug and the regulator discharges; when pressure returns to set point, it closes. Unlike a safety valve, it modulates: it opens in proportion to the excess pressure and works continuously.

Additional pressure loading on the diaphragm turns the regulator into a differential device: it holds a constant difference between the controlled pressure and a reference pressure, as a compressor seal or a lubrication system requires. When the flow to be discharged is large, the pilot-operated construction gives more capacity with less pressure buildup above the setting.

Constructions and trim

  • Spring-loaded MR98

    Direct-operated Types MR98L, MR98H and MR98HH, with elastomer seats for tight shutoff, graphite gaskets and constructions for arctic and cryogenic temperatures.

  • Pressure-loaded MR98

    Types MR98LD, MR98HD and MR98HHD for differential relief, backpressure against a reference or remote set point adjustment.

  • High-capacity MR108

    Direct-operated with a pressure-loaded actuator, for liquid, air and gas. The manufacturer indicates it for lube oil and for services where speed of response is critical or the fluid is not free of impurities.

  • Pilot-operated 63EG and 1808

    Relief or backpressure with a pilot for high flows and low buildup: the 63EG, top entry with quick-change trim; the 1808 and 1808A, compact, for oil and gas separators.

Applications

Where they are used

  • Pump recirculation: they hold discharge pressure by returning the excess to the tank or to suction
  • Lube and seal oil systems of compressors and turbomachinery, with differential control
  • Production separators and vessels, to sustain operating pressure
  • Steam, air and gas headers, where they limit pressure buildup
  • Relief downstream of pressure reducing regulators on gas and air

Why it is chosen

  • They hold upstream pressure without instrumentation, signal or external power
  • They modulate continuously: they discharge only the excess and reseat on return to set point
  • MR98 with tight shutoff on elastomer seats and easy maintenance, according to the manufacturer
  • Differential and remote-adjustment versions on the same parts base

Worth weighing

  • A back pressure or relief regulator controls pressure in operation; it does not replace the safety valve that protects the pressure equipment under the applicable code
  • The discharge must be routed to a safe point, and the back pressure of that line is taken into account when fixing the setting

ITS de Venezuela

What ITS does with back pressure regulators

ITS quotes new Fisher back pressure and relief regulators and their genuine parts (diaphragms, springs, plugs, seats and gaskets), and services installed ones: disassembly, inspection, soft parts replacement, bench testing and set point adjustment in the Puerto Ordaz workshop, plus field service, with the support of the Venezuela ↔ Orlando inventory. To get a quotation, send this data: fluid, pressure to be held upstream, pressure at the outlet, maximum and minimum flow to be discharged, temperature, connection size and type, and whether control is differential; or the model and serial number from the nameplate.

Quote parts or repair

Resources

Resources

The full category, the technical library and the manufacturer’s official documentation.

FAQ

Frequently asked questions

All frequently asked questions
How does it differ from a safety valve?

The back pressure regulator is a control device: it modulates continuously to hold upstream pressure at set point. The safety valve is a protection device: it stays closed in operation and opens only on overpressure, with the capacity required by the equipment code. A well-designed system usually has both, with the regulator set below the safety valve.

What is pressure loading for on the MR98?

It lets the regulator hold a differential pressure instead of a fixed pressure. The reference pressure is connected above the diaphragm and adds to the spring, so the controlled pressure follows the reference with a constant difference. It also allows the set point to be changed remotely by varying that loading pressure.

Regulators

More regulators families

Pressure reducing regulators

They hold downstream pressure constant with a diaphragm and a spring: the simple, fast solution for steam, water, air, gases and chemicals.

Pilot-operated regulators for natural gas

A pilot amplifies every slight change in outlet pressure and drives the main valve: more capacity and pressure closer to set point than direct operation.

Fuel gas valves

They open and close gas to the main burner with a tunable opening speed, so that ignition is correct on field heaters and treaters.

Slam-shut devices

They shut off the gas supply quickly and completely when pressure leaves the set limits, and stay closed until manually reset.

Steam regulators

They reduce steam pressure from the distribution lines to the level each consumer needs, on wet or dry steam and without instrument air.

Fisher OEM Parts is the online catalog of ACD America Corp., our parent company. It opens in a new tab.

Need back pressure regulators and relief, or repair for yours?

Send the model, the part number or the process data. We reply with availability, lead time and delivery terms.

Product bulletin

Loading the bulletin…

  1. 1Details
  2. 2Verification
  3. 3Request

Message us on WhatsApp

We verify your details and connect you with the specialist for your region.

Receive the phone code by

We will send one code to your email and another to your phone.